Low Energy Characterization of Caliste HD, a Fine Pitch CdTe-Based Imaging Spectrometer

Caliste HD is a recently developed micro-camera designed for X and gamma-ray astronomy, based on a 1×1 cm2 CdTe Schottky pixelated detector. Its entire surface is composed of 256 pixels, disposed on a 16 × 16 pixel array. This spectrometer is buttable on its 4 sides and can be used to create a large focal plane. It is also designed for space environment. Its IDeF-X front-end electronics has low power consumption, excellent noise performance and a wide dynamic range, from 2 keV to 1 MeV. Moreover, electronic noise performances of this device were optimized to set the low level energy threshold lower than 2 keV.

[1]  P. Giommi,et al.  Simbol-X: mission overview , 2006, SPIE Astronomical Telescopes + Instrumentation.

[2]  C. Budtz-Jørgensen,et al.  Modeling charge-sharing effects in pixellated CZT detectors , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[3]  Y. Ménesguen,et al.  Efficiency calibration and surface mapping of an energy-dispersive detector with SOLEX: A compact tunable monochromatic X-ray source , 2012 .

[4]  K. Perez Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 2014 .

[5]  Y. X. Wang,et al.  Nuclear Instruments and Methods in Physics Research Section B : Beam Interactions with Materials and Atoms , 2018 .

[6]  Peter Mao,et al.  The Nuclear Spectroscopic Telescope Array (NuSTAR) , 2010, Astronomical Telescopes + Instrumentation.

[7]  E. Delagnes,et al.  IDeF-X HD: A low power multi-gain CMOS ASIC for the readout of Cd(Zn)Te detectors , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[8]  J. Martignac,et al.  Caliste-SO X-ray micro-camera for the STIX instrument on-board Solar Orbiter space mission , 2012 .

[9]  E. Delagnes,et al.  Caliste HD: A new fine pitch Cd(Zn)Te imaging spectrometer from 2 keV up to 1 MeV , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[10]  O. Limousin,et al.  Charge sharing in CdTe pixilated detectors , 2009 .

[11]  O. Limousin,et al.  CALISTE 64, an innovative CdTe hard X-Ray micro-camera , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[12]  C. Bobin,et al.  Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source , 2007 .

[13]  J. Camplan,et al.  ARAMIS: An ambidextrous 2 MV accelerator for IBA and MeV implantation , 1990 .

[14]  Sandro Mereghetti,et al.  NHXM: a New Hard X-ray imaging and polarimetric Mission , 2010, Astronomical Telescopes + Instrumentation.

[15]  M. Funaki,et al.  A 90 element CdTe array detector , 1992 .

[16]  X. Barcons,et al.  The COSPIX mission: focusing on the energetic and obscured Universe , 2010 .

[17]  J. Martignac,et al.  Caliste 256: A CdTe imaging spectrometer for space science with a 580 μm pixel pitch , 2011 .

[18]  P. Jonnard,et al.  SOLEX: a tunable monochromatic X-ray source in the 1–20keV energy range for metrology , 2004 .

[19]  Eric Delagnes,et al.  Imaging X-ray detector front-end with high dynamic range: IDeF-X HD , 2012 .

[20]  Yoshiharu Namba,et al.  The ASTRO-H Mission , 2009, Astronomical Telescopes + Instrumentation.