Performance characteristics and modelling of a micro gas turbine for their integration with thermally activated cooling technologies

We have developed a simple model of a micro gas turbine system operating at high ambient temperatures and characterized its performance with a view to integrating this system with thermally activated cooling technologies. To develop and validate this model, we used experimental data from the micro gas turbine test facility of the CREVER research centre. The microturbine components were modelled and the thermodynamic properties of air and combustion gases were estimated using a commercial process simulator. Important information such as net output power, microturbine fuel consumption and exhaust gas mass flow rate can be obtained with the empirical correlations we have developed in this study. This information can be useful for design exhaust gas fired absorption chillers. Copyright © 2006 John Wiley & Sons, Ltd.

[1]  Ennio Macchi,et al.  Microturbines and Trigeneration: Optimization Strategies and Multiple Engine Configuration Effects , 2004 .

[2]  R Di Lorenzo,et al.  Optimal design of tube hydroforming processes: A fuzzy-logic-based approach , 2004 .

[3]  Siaw Kiang Chou,et al.  Performance study of a microturbine system for cogeneration application , 2004 .

[4]  Alberto Coronas,et al.  Performance analysis of combined microgas turbines and gas fired water/LiBr absorption chillers with post-combustion , 2005 .

[5]  Romano Giglioli,et al.  System Description and Test Planning for a Combined Heat and Power (CHP) Plant Composed by a Micro Gas Turbine and an Absorption Chiller / Heater , 2001 .

[6]  Yunho Hwang,et al.  Potential energy benefits of integrated refrigeration system with microturbine and absorption chiller , 2004 .

[7]  Paolo Iora,et al.  Heat recovery from a micro-gas turbine by vapour jet refrigeration systems , 2005 .

[8]  P. D. Fairchild Experimental and Theoretical Study of Microturbine-Based BCHP System , 2001 .

[9]  E Makin,et al.  Speed estimation and control in a belt-driven system for a web production process. Part 1: System modelling and validation , 2004 .

[10]  P. A. Pilavachi Mini- and micro-gas turbines for combined heat and power , 2002 .

[11]  Na Zhang,et al.  General characteristics of single shaft microturbine set at variable speed operation and its optimization , 2004 .

[12]  Warren D. Seider,et al.  Process design principles : synthesis, analysis, and evaluation , 1999 .

[13]  C. Schweigler,et al.  Heat Transfer Characteristics in Flue Gas Fired Regenerators of Water/Lithium Bromide Absorption Chillers , 2006 .

[14]  Jorge Andaverde,et al.  Uncertainty estimates of static formation temperatures in boreholes and evaluation of regression models , 2005 .

[15]  Reinhard Radermacher,et al.  SECOND GENERATION INTEGRATED MICROTURBINE, ABSORPTION CHILLER, AND SOLID WHEEL DESICCANT SYSTEM , 2003 .

[16]  Na Zhang,et al.  Analytical solutions and typical characteristics of part-load performances of single shaft gas turbine and its cogeneration , 2002 .