Modeling ventilation rates in bedrooms based on building characteristics and occupant behavior

Abstract Air change rate (ACR) data obtained from the bedrooms of 500 Danish children and presented in an earlier paper were analyzed in more detail. Questionnaires distributed to the families, home inspections and interviews with the parents provided information about a broad range of residential characteristics and occupant behavior. These were tested in several linear regression models to identify the degree of effect each selected independent variable has on the total ACR. The measured ACRs are summarized by some of the most significant variables such as room volume (higher ACR in smaller rooms), number of people sleeping in the bedroom (higher ACR with more people), average window and door opening habits (higher ACR with more opening), sharing the bedroom with other family members (higher ACR in shared rooms), location of the measured room (higher ACR above ground floor), year of construction (lowest ACR in buildings from early 1970s), observed condensation on the bedroom window (higher ACR at less condensation), etc. The best-fitting model explained 46% of the variability in the air change rates. Variables related to occupant behavior were stronger predictors of ventilation rate (model R2 = 0.30) than those related to building characteristics (model R2 = 0.09). Although not perfectly accurate on a room-to-room basis, our best-fitting model may be useful when a rough estimate of the average air change rate for larger study populations is required in future indoor air quality models.

[1]  C. Bornehag,et al.  Building characteristics associated with moisture related problems in 8,918 Swedish dwellings , 2009, International journal of environmental health research.

[2]  G. Iwashita,et al.  The effects of human behavior on natural ventilation rate and indoor air environment in summer − a field study in southern Japan , 1997 .

[3]  S. Colome,et al.  California residential air exchange rates and residence volumes. , 1996, Journal of exposure analysis and environmental epidemiology.

[4]  F Engdahl Stability of mechanical exhaust systems. , 1999, Indoor air.

[5]  Donal Finn,et al.  Sensitivity of air change rates in a naturally ventilated atrium space subject to variations in external wind speed and direction , 2008 .

[6]  W. Ott,et al.  The Effect of Opening Windows on Air Change Rates in Two Homes , 2002, Journal of the Air & Waste Management Association.

[7]  M Svartengren,et al.  Building characteristics, indoor air quality and recurrent wheezing in very young children (BAMSE). , 2004, Indoor air.

[8]  David E. Burmaster,et al.  Residential Air Exchange Rates in the United States: Empirical and Estimated Parametric Distributions by Season and Climatic Region , 1995 .

[9]  Youming Chen,et al.  Investigating potential of natural driving forces for ventilation in four major cities in China , 2005 .

[10]  Leif Øie,et al.  Is diabetes mellitus associated with prostate cancer incidence and survival , 1999 .

[11]  Hans Stymne,et al.  Measuring ventilation rates in the Swedish housing stock , 1994 .

[12]  O Seppänen,et al.  Ventilation and health in non-industrial indoor environments: report from a European multidisciplinary scientific consensus meeting (EUROVEN). , 2002, Indoor air.

[13]  D G Shendell,et al.  Residential air exchange rates in three major US metropolitan areas: results from the Relationship Among Indoor, Outdoor, and Personal Air Study 1999-2001. , 2010, Indoor air.

[14]  C.-F. Gao,et al.  Evaluating the influence of openings configuration on natural ventilation performance of residential , 2011 .

[15]  Carl-Eric Hagentoft,et al.  Probabilistic analysis of air infiltration in low-rise buildings. , 2008 .

[16]  Leif Øie,et al.  The Ventilation Rate of 344 Oslo Residences , 1998 .

[17]  Glenn Gamst,et al.  Applied Multivariate Research: Design and Interpretation , 2005 .

[18]  Jørn Toftum,et al.  Ventilation rates in the bedrooms of 500 Danish children , 2010 .

[19]  N. Åberg,et al.  'Dampness' at home and its association with airway, nose, and skin symptoms among 10,851 preschool children in Sweden: a cross-sectional study. , 2005, Indoor air.

[20]  J Sundell,et al.  Association between ventilation rates in 390 Swedish homes and allergic symptoms in children. , 2005, Indoor air.

[21]  Max H. Sherman Air change rate and airtightness in buildings , 1990 .

[22]  B Kvisgaard,et al.  The User's Influence on Air Change , 1990 .

[23]  M. Wickman,et al.  Ventilation in homes infested by house‐dust mites , 1995, Allergy.

[24]  K. Bartlett,et al.  Modeling of Occupant-Generated CO2 Dynamics in Naturally Ventilated Classrooms , 2004, Journal of occupational and environmental hygiene.

[25]  L. Wallace,et al.  Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows* , 2002, Journal of Exposure Analysis and Environmental Epidemiology.

[26]  Emenius,et al.  Mechanical ventilation protects one‐storey single‐dwelling houses against increased air humidity, domestic mite allergens and indoor pollutants in a cold climatic region , 1998, Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology.

[27]  J. Fox Applied Regression Analysis, Linear Models, and Related Methods , 1997 .

[28]  N. C. Bergsøe,et al.  Radon and Natural Ventilation in Newer Danish Single‐Family Houses , 1997 .

[29]  Olli Seppänen,et al.  Indoor Climate and the Performance of Ventilation in Finnish Residences , 1992 .

[30]  Jan Sundell,et al.  Indoor Air Humidity And Sensation Of Dryness As Risk Indicators Of Sbs , 1993 .

[31]  R. Dahl,et al.  House‐dust mites and associated environmental conditions in Danish homes , 1993, Allergy.

[32]  Emenius,et al.  Window pane condensation and high indoor vapour contribution − markers of an unhealthy indoor climate? , 2000, Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology.

[33]  Michael S. Breen,et al.  Predicting Residential Air Exchange Rates from Questionnaires and Meteorology: Model Evaluation in Central North Carolina , 2010, Environmental science & technology.

[34]  G. Pershagen,et al.  Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to "dampness" in buildings and health effects (NORDDAMP). , 2001, Indoor air.