Energy loss due to paravalvular leak with transcatheter aortic valve implantation.

BACKGROUND Mild to moderate paravalvular leaks commonly occur after transcatheter aortic valve (TAV) implantation. Current TAVs match and may exceed hemodynamic performance of surgically implanted bioprostheses based on pressure gradient and effective orifice area. However, these hemodynamic criteria do not account for paravalvular leaks. We recently demonstrated that TAV implantation within 23 mm Perimount bioprostheses (Edwards Lifesciences, Irvine, CA) yields similar hemodynamics to the 23 mm Perimount valve. However, mild paravalvular leakage was seen after TAV implantation. The present study quantifies energy loss during the entire cardiac cycle to assess the impact of TAV paravalvular leaks on the ventricle. METHODS Four TAVs designed to mimic the 23 mm SAPIEN valve (Edwards Lifesciences) were created. Transvalvular energy loss of 19, 21, and 23 mm Carpentier-Edwards bioprostheses were obtained in vitro within a pulse duplicator as a hemodynamic baseline (n = 4). The 23 mm TAVs were subsequently implanted within the 23 mm bioprostheses to assess energy loss due to paravalvular leak. RESULTS The 23 mm bioprosthesis demonstrated the least energy loss (213.25 +/- 31.35 mJ) compared with the 19 mm (330.00 +/- 36.97 mJ, p = 0.003) and 21 mm bioprostheses (298.00 +/- 37.25 mJ, p = 0.008). The TAV controls had similar energy loss (241.00 +/- 30.55 mJ, p = 0.17) as the 23 mm bioprostheses. However, after TAV implantation, total energy loss increased to 365.33 +/- 8.02 mJ significantly exceeding the energy loss of the 23 mm bioprosthesis (p < 0.001). Due to mild TAV paravalvular leakage, 39% of energy loss occurred during diastole. CONCLUSIONS Substantial energy loss during diastole occurs due to TAV paravalvular leakage. In the presence of mild paravalvular leakage, TAV implantation imposes a significantly higher workload on the left ventricle than an equivalently sized surgically implanted bioprosthesis.

[1]  Mirko Doss,et al.  Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience , 2007, Circulation.

[2]  M. Kotler,et al.  Evaluation of hemolysis in patients with prosthetic heart valves , 1998, Clinical cardiology.

[3]  P. Pibarot,et al.  Assessment of aortic valve stenosis severity: A new index based on the energy loss concept. , 2000, Circulation.

[4]  Thomas Walther,et al.  Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. , 2007, Journal of the American College of Cardiology.

[5]  J. Albes,et al.  Different Tilting Disc Valves Show Similar Rotation-Dependent Impairment in Hemodynamic Performance under a Tilted Implantation Position1 , 2005, The Thoracic and cardiovascular surgeon.

[6]  A. Fraser,et al.  Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography , 2003, Heart.

[7]  N. Wilson,et al.  Surgery Insight: percutaneous treatment of prosthetic paravalvular leaks , 2008, Nature Clinical Practice Cardiovascular Medicine.

[8]  I. McDonald,et al.  Left ventricular energy in mitral regurgitation: a preliminary report. , 1992, Australian and New Zealand journal of medicine.

[9]  Francesco Maisano,et al.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  C. Ruiz,et al.  Percutaneous transcatheter aortic valve implantation: Evolution of the technology. , 2009, American heart journal.

[11]  V. Falk,et al.  Hemodynamic evaluation of heart valve prostheses paradigm shift for transcatheter valves? , 2009, Journal of the American College of Cardiology.

[12]  P. Pibarot,et al.  Left ventricular longitudinal shortening in patients with aortic stenosis: relationship with symptomatic status. , 2002, The Journal of heart valve disease.

[13]  Anson Cheung,et al.  Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience , 2006, Circulation.

[14]  Assaf Bash,et al.  Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. , 2004, Journal of the American College of Cardiology.

[15]  J. Bermejo,et al.  Clinical efficacy of Doppler-echocardiographic indices of aortic valve stenosis: a comparative test-based analysis of outcome. , 2003, Journal of the American College of Cardiology.

[16]  A. Cribier,et al.  Outcomes and safety of percutaneous aortic valve replacement. , 2009, Journal of the American College of Cardiology.

[17]  Philippe Pibarot,et al.  Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis. , 2009, Journal of the American College of Cardiology.

[18]  Lukas Altwegg,et al.  Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis , 2007, Circulation.

[19]  Francis Robicsek,et al.  A method for the measurement of left ventricular overload for aortic valve insufficiency. , 2009, Journal of biomechanics.

[20]  A. Azadani,et al.  Aortic valve-in-valve implantation: impact of transcatheter- bioprosthesis size mismatch. , 2009, The Journal of heart valve disease.

[21]  M. Oz,et al.  Transcatheter aortic valve replacement in patients with critical aortic stenosis: rationale, device descriptions, early clinical experiences, and perspectives. , 2006, Seminars in thoracic and cardiovascular surgery.

[22]  Robert A. Levine,et al.  Experimental analysis of fluid mechanical energy losses in aortic valve stenosis: Importance of pressure recovery , 1996, Annals of Biomedical Engineering.

[23]  A. Yoganathan,et al.  Energy loss for evaluating heart valve performance. , 2008, The Journal of thoracic and cardiovascular surgery.

[24]  C. Higgins,et al.  Mitral or aortic regurgitation: quantification of regurgitant volumes with cine MR imaging. , 1988, Radiology.

[25]  P. Pibarot,et al.  Feasibility and initial results of percutaneous aortic valve implantation including selection of the transfemoral or transapical approach in patients with severe aortic stenosis. , 2008, The American journal of cardiology.

[26]  A. Cribier,et al.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. , 2006, Journal of the American College of Cardiology.

[27]  J Fisher,et al.  Comparative study of the hydrodynamic function of six size 19 mm bileaflet heart valves. , 1995, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[28]  M. Mack,et al.  United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex. , 2008, The Annals of thoracic surgery.