Fine-scale motion detection using intrinsic list mode PET information

Motion during extended nuclear medicine scanning sequences can significantly degrade the quality of reconstructed images. Correction for this motion requires an accurate motion sensor. We describe a technique to detect motion in list mode positron emission tomography (PET) imagery that relies upon information from the list mode data stream itself. In studies where the tracer contrast to background contrast is high, the axial component of the center of mass (CM) for tomograph events can serve as an accurate indicator of motion. Because the method does not require reconstruction of images, it may be applied to motion detection at a very fine temporal scale. The technique has been applied to the detection of motion due to the respiratory cycle in cardiac PET imaging.

[1]  T F Budinger Developments in digital computer implementation in nuclear medicine imaging. , 1975, Computers and biomedical research, an international journal.

[2]  M E Phelps,et al.  Electrocardiographic gating in positron emission computed tomography. , 1979, Journal of computer assisted tomography.

[3]  H. Hricak,et al.  Magnetic resonance imaging with respiratory gating: techniques and advantages. , 1984, AJR. American journal of roentgenology.

[4]  Richard L. Ehman,et al.  A monitoring, feedback, and triggering system for reproducible breath‐hold MR imaging , 1993, Magnetic resonance in medicine.

[5]  G Germano,et al.  Temporal image fractionation: rejection of motion artifacts in myocardial SPECT. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Y. Picard,et al.  Motion correction of PET images using multiple acquisition frames , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[7]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[8]  G. J. Klein,et al.  Real-time system for respiratory-cardiac gating in positron tomography , 1997 .

[9]  S M Mijailovich,et al.  Effects of lung motion and tracer kinetics corrections on PET imaging of pulmonary function. , 1997, Journal of applied physiology.

[10]  Ronald H. Huesman,et al.  A methodology for specifying PET VOIs using multimodality techniques , 1997, IEEE Transactions on Medical Imaging.

[11]  M. O’Connor,et al.  Comparison of four motion correction techniques in SPECT imaging of the heart: a cardiac phantom study. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.