In vivo investigation of restricted diffusion in the human brain with optimized oscillating diffusion gradient encoding

Previous studies in phantoms and animals using animal MR systems have shown promising results in using oscillating gradient spin echo (OGSE) diffusion acquisition to depict microstructure information. The OGSE approach has also been shown to be a sensitive biomarker of tumor treatment response and white matter‐related diseases. Translating these studies to a human MR scanner faces multiple challenges due to the much weaker gradient system. The goals of this study are to optimize the OGSE acquisition for a human MR system and investigate its applicability in the in vivo human brain.

[1]  P. Callaghan,et al.  Low-frequency velocity correlation spectrum of fluid in a porous media by modulated gradient spin echo. , 2001, Magnetic resonance imaging.

[2]  Weili Lin,et al.  A fast, iterative, partial-fourier technique capable of local phase recovery , 1991 .

[3]  Denis Le Bihan,et al.  Diffusion, confusion and functional MRI , 2012, NeuroImage.

[4]  K. Svoboda,et al.  Time-dependent diffusion of water in a biological model system. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[5]  T. A. Carpenter,et al.  Optimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain. , 1997, Magnetic resonance imaging.

[6]  Dmitry S Novikov,et al.  Surface-to-volume ratio with oscillating gradients. , 2011, Journal of magnetic resonance.

[7]  Murat Aksoy,et al.  Diffusion tensor imaging (DTI) with retrospective motion correction for large‐scale pediatric imaging , 2012, Journal of magnetic resonance imaging : JMRI.

[8]  G J Barker,et al.  Self‐diffusion in CNS tissue by volume‐selective proton NMR , 1994, Magnetic resonance in medicine.

[9]  Janez Stepišnik,et al.  Analysis of NMR self-diffusion measurements by a density matrix calculation , 1981 .

[10]  E. Akbudak,et al.  Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results , 1996, Magnetic resonance in medicine.

[11]  M. Hedehus,et al.  Diffusion time dependence of the apparent diffusion tensor in healthy human brain and white matter disease , 2001, Magnetic resonance in medicine.

[12]  Paul T. Callaghan,et al.  Frequency-Domain Analysis of Spin Motion Using Modulated-Gradient NMR , 1995 .

[13]  S. Skare,et al.  Robust GRAPPA‐accelerated diffusion‐weighted readout‐segmented (RS)‐EPI , 2009, Magnetic resonance in medicine.

[14]  J C Gore,et al.  Measurements of restricted diffusion using an oscillating gradient spin-echo sequence. , 2000, Journal of magnetic resonance.

[15]  D. Le Bihan,et al.  Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. , 1988, Radiology.

[16]  Junzhong Xu,et al.  Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy , 2010, NMR in biomedicine.

[17]  David S. Martin,et al.  Diffusion and Perfusion Magnetic Resonance Imaging: Applications to Functional MRI , 1996 .

[18]  S. Mori,et al.  Probing mouse brain microstructure using oscillating gradient diffusion MRI , 2012, Magnetic resonance in medicine.

[19]  Joachim Hornegger,et al.  Real‐time optical motion correction for diffusion tensor imaging , 2011, Magnetic resonance in medicine.

[20]  W. T. Dixon,et al.  Measuring diffusion in inhomogeneous systems in imaging mode using antisymmetric sensitizing gradients , 1992 .

[21]  Tim B. Dyrby,et al.  Orientationally invariant indices of axon diameter and density from diffusion MRI , 2010, NeuroImage.

[22]  Thomas E. Yankeelov,et al.  Earlier detection of tumor treatment response using magnetic resonance diffusion imaging with oscillating gradients. , 2011, Magnetic resonance imaging.

[23]  M. Bronskill,et al.  T1, T2 relaxation and magnetization transfer in tissue at 3T , 2005, Magnetic resonance in medicine.

[24]  Sune N Jespersen,et al.  The effect of impermeable boundaries of arbitrary geometry on the apparent diffusion coefficient. , 2008, Journal of magnetic resonance.

[25]  John C Gore,et al.  Modified oscillating gradient pulses for direct sampling of the diffusion spectrum suitable for imaging sequences. , 2003, Magnetic resonance imaging.

[26]  Wilson Fong Handbook of MRI Pulse Sequences , 2005 .

[27]  J. Cuppen,et al.  Reducing MR imaging time by one-sided reconstruction , 1987 .

[28]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[29]  Igor Sersa,et al.  Spectral characterization of diffusion in porous media by the modulated gradient spin echo with CPMG sequence. , 2006, Journal of magnetic resonance.

[30]  John C Gore,et al.  Temporal diffusion spectroscopy: Theory and implementation in restricted systems using oscillating gradients , 2006, Magnetic resonance in medicine.

[31]  Stefan Skare,et al.  Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noise , 2007, Magnetic resonance in medicine.

[32]  J. Gore,et al.  Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain , 2003, Magnetic resonance in medicine.

[33]  P. Bhattacharya Diffusion MRI: Theory, methods, and applications, Derek K. Jones (Ed.). Oxford University press (2011), $152.77 , 2012 .

[34]  Paul T. Callaghan,et al.  The long time tail of molecular velocity correlation in a confined fluid: observation by modulated gradient spin-echo NMR , 2000 .

[35]  Jing Yuan,et al.  Tailored utilization of acquired k-space points for GRAPPA reconstruction. , 2005, Journal of magnetic resonance.

[36]  D Le Bihan,et al.  Is water diffusion restricted in human brain white matter? An echo-planar NMR imaging study. , 1993, Neuroreport.