Modeling and realization of a 6-DoF contactless electromagnetic anti-vibration system and verification of its static behavior

This paper concerns measurements on an electromagnetic six Degrees-of-Freedom (DoF) anti-vibration system that has been realized recently. The heart of this system is a fully passive permanent-magnet device which acts as a contactless magnetic spring. As such, the gravity force of a floating rigid metrology frame (730 kg) is compensated by the passive interaction between the permanent magnets in this device. The low position dependency of this force, or stiffness, is an important system property for floor vibration isolation. This 6-DoF system is stabilized by closed-loop controlled Lorentz actuators based on position feedback. The static force and torque of this system have been obtained experimentally to validate the modeling and design of the device. The results indicate a temperature sensitivity of 1.70/00/K which corresponds to -12.1 N/K compared to the vertical force of 7.2 kN. The passive force and torque produced by the gravity compensator have linear relation with translational and rotational displacements. The predicted low stiffness property of this system is validated by the stiffness matrix derived from static measurements. The total power consumption is position dependent and remains within a range of 0.3~6 W.

[1]  Mf Marcel Heertjes,et al.  Active vibration isolation of metrology frames; a modal decoupled control design , 2005 .

[2]  Kees de Kort,et al.  Rare earth permanent magnets , 1995 .

[3]  Allen J. Bronowicki Vibration Isolator for Large Space Telescopes , 2006 .

[4]  Fu-Cheng Wang,et al.  Robust Control Design for Vibration Isolation of an Electron Beam Projection Lithography System , 2010 .

[5]  S. Earnshaw On the Nature of the Molecular Forces which Regulate the Constitution of the Luminiferous Ether , .

[6]  Jlg Jeroen Janssen,et al.  Extended analytical charge modeling for permanent-magnet based devices : practical application to the interactions in a vibration isolation system , 2011 .

[7]  Johannes J. H. Paulides,et al.  Three-Dimensional Analytical Calculation of the Torque Between Permanent Magnets in Magnetic Bearings , 2010, IEEE Transactions on Magnetics.

[8]  Kwang-Joon Kim,et al.  Modeling of nonlinear complex stiffness of dual-chamber pneumatic spring for precision vibration isolations , 2007 .

[9]  Ryota Shimizu,et al.  Systematic analyses of vibration noise of a vibration isolation system for high-resolution scanning tunneling microscopes. , 2011, The Review of scientific instruments.

[10]  Jlg Jeroen Janssen,et al.  Analytical force and stiffness calculations for magnetic bearings and vibration isolation , 2009 .

[11]  Abdelmounaïm Tounzi,et al.  Analytical calculation of interaction force between orthogonally magnetized permanent magnets , 2009 .

[12]  Mf Marcel Heertjes,et al.  Nonlinear Dynamics and Control of a Pneumatic Vibration Isolator , 2006 .

[13]  Hiroshi Iseki,et al.  Vibration Isolation for Seismocardiogram Measurement in the OpenMRI-Guided Operating Theater , 2003 .

[14]  Michael Lamperth,et al.  Development of a multi-degree-of-freedom micropositioning, vibration isolation and vibration suppression system , 2007 .