Aseptic loosening of femoral components - materials engineering and design considerations
暂无分享,去创建一个
Farzam Farahmand | Marjan Bahraminasab | Kevin L. Edwards | Manohar Arumugam | K. L. Edwards | F. Farahmand | K. Edwards | M. Bahraminasab | B. Sahari | Barkawi Sahari | M. Arumugam | Marjan Bahraminasab
[1] J. Stiehl,et al. The spectrum of prosthesis design for primary total knee arthroplasty. , 2003, Instructional course lectures.
[2] J. Huddleston,et al. Long-term comparison of mobile-bearing vs fixed-bearing total knee arthroplasty. , 2011, The Journal of arthroplasty.
[3] J. Besjakov,et al. A clinical and radiostereometric study of the cemented PFC-sigma prosthesis: a 5-year study of 29 cases with a fixed bearing. , 2009, The journal of knee surgery.
[4] K. L. Edwards,et al. Design, materials selection and marketing of successful products , 2003 .
[5] J. Jurvelin,et al. Periprosthetic femoral bone loss after total knee arthroplasty: 1-year follow-up study of 69 patients. , 2004, The Knee.
[6] A. Navarro-Quilis,et al. Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening? , 2008, The Journal of arthroplasty.
[7] A. Singh,et al. Ti based biomaterials, the ultimate choice for orthopaedic implants – A review , 2009 .
[8] J. Callaghan,et al. Osteolysis Associated with a Cemented tModular Posterior-Cruciate-Substituting Total Knee Design: Five to Eight-Year Follow-up , 2002, The Journal of bone and joint surgery. American volume.
[9] H. Oonishi,et al. Development and Improvement of Ceramic TKP for 19 Years and Clinical Results , 2001 .
[10] M Navarro,et al. Biomaterials in orthopaedics , 2008, Journal of The Royal Society Interface.
[11] Duncan Dowson,et al. The role of counterface imperfections in the wear of polyethylene , 1987 .
[12] C. Ranawat,et al. Review Article: Osteolysis After Total Knee Arthroplasty , 2007 .
[13] J. Davim,et al. Tribological Comparative Study of Conventional and Composite Materials in Biomedical Applications , 2002 .
[14] I. Clarke,et al. Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation , 2006, Acta orthopaedica.
[15] Y.-M. Deng,et al. Supporting design decision-making when applying materials in combination , 2007 .
[16] H. Rack,et al. Titanium alloys in total joint replacement--a materials science perspective. , 1998, Biomaterials.
[17] W. Harmsen,et al. Revision Total Knee Arthroplasty With Modular Cemented Stems , 2007 .
[18] F. Cui,et al. A simple method to prepare calcium phosphate coatings on Ti6Al4V , 1997, Journal of materials science. Materials in medicine.
[19] J. Paulo Davim,et al. Evaluation of Tribological Behaviour of Polymeric Materials for Hip Prostheses Application , 2001 .
[20] David F. Williams. On the nature of biomaterials. , 2009, Biomaterials.
[21] K. L. Edwards. Towards an improved development process for new hip prostheses , 2008 .
[22] M. Laberge,et al. UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation , 2008 .
[23] A. Wang,et al. Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement , 1998 .
[24] Peter Greil,et al. Functionally graded materials for biomedical applications , 2003 .
[25] M. Raimondi,et al. The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating. , 2000, Biomaterials.
[26] A Unsworth,et al. Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials , 2009, Journal of materials science. Materials in medicine.
[27] J. Simões,et al. Relationship of design features of stemmed tibial knee prosthesis with stress shielding and end-of-stem pain , 2009 .
[28] Chockalingam,et al. The outcome of cemented vs. cementless fixation of a femoral component in total knee replacement (TKR) with the identification of radiological signs for the prediction of failure. , 2000, The Knee.
[29] A. Amirfazli,et al. Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements. , 2007, Journal of biomechanics.
[30] L. Topoleski,et al. Third-body wear of cobalt-chromium-molybdenum implant alloys initiated by bone and poly(methyl methacrylate) particles. , 2000, Journal of biomedical materials research.
[31] A. van Kampen,et al. Distal femoral bone mineral density decreases following patellofemoral arthroplasty: 1-year follow-up study of 14 patients , 2010, BMC musculoskeletal disorders.
[32] M. Ashby,et al. Cellular solids: Structure & properties , 1988 .
[33] Mikio Iwamoto,et al. PE wear in ceramic/PE bearing surface in total knee arthroplasty: Clinical experiences of more than 24 years , 2006 .
[34] P. J. Gregg,et al. A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacement , 2002 .
[35] T. Brown,et al. Scratching vulnerability of conventional vs highly cross-linked polyethylene liners because of large embedded third-body particles. , 2012, The Journal of arthroplasty.
[36] Kevin L. Edwards,et al. Materials influence on design: A decade of development , 2011 .
[37] W. Ortega-Lara,et al. Mechanical properties and apatite-forming ability of PMMA bone cements , 2009 .
[38] S. Kurtz,et al. PEEK biomaterials in trauma, orthopedic, and spinal implants. , 2007, Biomaterials.
[39] P. Christel,et al. Wear analysis of retrieved alumina heads and sockets of hip prostheses. , 1989, Journal of Biomedical Materials Research.
[40] E. Axinte. Metallic glasses from “alchemy” to pure science: Present and future of design, processing and applications of glassy metals , 2012 .
[41] J. Paulo Davim,et al. Effect of carbon fibre reinforcement in the frictional behaviour of Peek in a water lubricated environment , 2001 .
[42] C. Rorabeck,et al. Wear and osteolysis around total knee arthroplasty. , 2007, The Journal of the American Academy of Orthopaedic Surgeons.
[43] A. Unsworth,et al. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether—ether—ketone) acetabular cup articulating against an alumina femoral head , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[44] V. Jansson,et al. Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo. , 2010, Acta biomaterialia.
[45] J. Liau,et al. Osteolysis in Failed Total Knee Arthroplasty: A Comparison of Mobile-Bearing and Fixed-Bearing Knees , 2002, The Journal of bone and joint surgery. American volume.
[46] Johan Bellemans,et al. Total knee arthroplasty: a guide to get better performance , 2005 .
[47] Aiguo Wang,et al. Mechanical properties and fatigue performance of crosslinked polyethylene in total knee applications , 2003 .
[48] B. Bal,et al. Primary Total Knee Replacement with a Zirconia Ceramic Femoral Component , 2005 .
[49] Ali Jahan,et al. Material selection for femoral component of total knee replacement using comprehensive VIKOR , 2011 .
[50] Mahmoud Nemat-Alla,et al. Reduction of thermal stresses by developing two-dimensional functionally graded materials , 2003 .
[51] M. Lee,et al. Ceramic Femoral Prosthesis in TKA — Present and Future , 2007 .
[52] F. Migliavacca,et al. Biomedical Applications of Shape Memory Alloys , 2011 .
[54] P. Sharkey,et al. Why Are Total Knee Arthroplasties Failing Today? , 2002 .
[55] J. Rand,et al. Cemented long-stem revision total knee arthroplasty. , 2003, Clinical orthopaedics and related research.
[56] G. H. van Lenthe,et al. Stemmed femoral knee prostheses , 2002 .
[57] R. Bader,et al. Ceramic knee endoprostheses: reality or future? , 2006 .
[58] C. Engh,et al. Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. , 2005, The Journal of bone and joint surgery. American volume.
[59] H. S. Hedia. Design of functionally graded dental implant in the presence of cancellous bone. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.
[60] R. Narayan,et al. The use of functionally gradient materials in medicine , 2006 .
[61] J. Galante,et al. Problems With Cementless Total Knee Arthroplasty at 11 Years Followup , 2001, Clinical orthopaedics and related research.
[62] K. Lai,et al. Early mechanical complications of a multidirectional mobile-bearing total knee replacement. , 2011, The Journal of bone and joint surgery. British volume.
[63] L. Claes,et al. Osseointegration of alumina with a bioactive coating under load-bearing and unloaded conditions. , 2005, Biomaterials.
[64] Farzam Farahmand,et al. Aseptic loosening of femoral components – A review of current and future trends in materials used , 2012 .
[65] H. Skinner. Ceramics in Total Joint Surgery: The Pros and Cons , 2006 .
[66] J. Chevalier,et al. Ceramics for medical applications: A picture for the next 20 years , 2009 .
[67] Eugene Ryshkewitch,et al. Compression Strength of Porous Sintered Alumina and Zirconia , 1953 .
[68] R. Bourne,et al. Wear Performance of Ultra-High Molecular Weight Polyethylene on Oxidized Zirconium Total Knee Femoral Components , 2001, The Journal of bone and joint surgery. American volume.
[69] Günther Heimke,et al. Knee arthoplasty: recently developed ceramics offer new solutions. , 2002, Biomaterials.
[70] T. Pandorf,et al. Advanced Testing of Ceramic Femoral Knee Components , 2007 .
[71] M H Stone,et al. Some factors affecting the strength of the cement-metal interface. , 1989, The Journal of bone and joint surgery. British volume.
[72] J W Goodfellow,et al. Unicompartmental Oxford Meniscal knee arthroplasty. , 1987, The Journal of arthroplasty.
[73] W. Harmsen,et al. Revision total knee arthroplasty with modular cemented stems: long-term follow-up. , 2007, The Journal of arthroplasty.
[74] C. Bünger,et al. A review of ceramic coatings for implant fixation. , 1999, Journal of long-term effects of medical implants.
[75] C. Ranawat,et al. Total Condylar Knee Replacement: A 20-Year Followup Study , 2001, Clinical orthopaedics and related research.
[76] H. Oonishi,et al. Surface Analysis on Retrieved Ceramic Total Knee Prosthesis , 2001 .
[77] S. Affatato,et al. Implant fixation in knee replacement: preliminary in vitro comparison of ceramic and metal cemented femoral components. , 2009, The Knee.
[78] A. Lombardi,et al. Evolution of tibial fixation in total knee arthroplasty. , 2007, The Journal of arthroplasty.
[79] A. Essner,et al. A highly crosslinked UHMWPE for CR and PS total knee arthroplasties. , 2008, The Journal of arthroplasty.
[80] A Unsworth,et al. The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[81] J. Yang,et al. Hybrid component fixation in total knee arthroplasty: minimum of 10-year follow-up study. , 2007, The Journal of arthroplasty.
[82] Y. Ishii,et al. Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty? , 1999, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.
[83] N Verdonschot,et al. Finite Element Analysis of the Long-Term Fixation Strength of Cemented Ceramic Cups , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[84] R. Huiskes,et al. Stemmed femoral knee prostheses: effects of prosthetic design and fixation on bone loss. , 2002, Acta orthopaedica Scandinavica.
[85] P J Gregg,et al. A randomised controlled trial of cemented versus cementless press-fit condylar total knee replacement: 15-year survival analysis. , 2007, The Journal of bone and joint surgery. British volume.
[86] B. Bal,et al. Ceramic Materials in Total Joint Arthroplasty , 2006 .
[87] J. Tamura,et al. Bioactive bone cements containing nano-sized titania particles for use as bone substitutes. , 2005, Biomaterials.
[88] V. Jansson,et al. Wear of contemporary total knee replacements--a knee simulator study of six current designs. , 2009, Clinical biomechanics.
[89] K. Katti,et al. Biomaterials in total joint replacement. , 2004, Colloids and surfaces. B, Biointerfaces.
[90] N. Verdonschot,et al. A sliding stem in revision total knee arthroplasty provides stability and reduces stress shielding , 2010, Acta orthopaedica.