Aseptic loosening of femoral components - materials engineering and design considerations

Aseptic loosening is one of the main reasons for the revision of a total knee replacement (TKR). The design of the key component of a TKR, the femoral component, is particularly problematic because its failure can be the result of different causes. This makes the development of new biomaterials for use in the femoral component a challenging task. This paper focuses on the engineering design aspects in order to understand the limitations of current materials and design deficiencies. The paper describes the introduction of a new biomaterial for a femoral component and justifies the recommendation to use multi-functional materials as a possible solution to aseptic loosening. The potential advantages of applying functionally graded biomaterials (FGBMs) in prosthetic femur are explained by reducing the leading causes of failure including wear, micro-motion and stress-shielding effect. The ideas presented in this paper can be used as the basis for further research on the feasibility and advantages of applying FGBM in other superior implant designs.

[1]  J. Stiehl,et al.  The spectrum of prosthesis design for primary total knee arthroplasty. , 2003, Instructional course lectures.

[2]  J. Huddleston,et al.  Long-term comparison of mobile-bearing vs fixed-bearing total knee arthroplasty. , 2011, The Journal of arthroplasty.

[3]  J. Besjakov,et al.  A clinical and radiostereometric study of the cemented PFC-sigma prosthesis: a 5-year study of 29 cases with a fixed bearing. , 2009, The journal of knee surgery.

[4]  K. L. Edwards,et al.  Design, materials selection and marketing of successful products , 2003 .

[5]  J. Jurvelin,et al.  Periprosthetic femoral bone loss after total knee arthroplasty: 1-year follow-up study of 69 patients. , 2004, The Knee.

[6]  A. Navarro-Quilis,et al.  Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening? , 2008, The Journal of arthroplasty.

[7]  A. Singh,et al.  Ti based biomaterials, the ultimate choice for orthopaedic implants – A review , 2009 .

[8]  J. Callaghan,et al.  Osteolysis Associated with a Cemented tModular Posterior-Cruciate-Substituting Total Knee Design: Five to Eight-Year Follow-up , 2002, The Journal of bone and joint surgery. American volume.

[9]  H. Oonishi,et al.  Development and Improvement of Ceramic TKP for 19 Years and Clinical Results , 2001 .

[10]  M Navarro,et al.  Biomaterials in orthopaedics , 2008, Journal of The Royal Society Interface.

[11]  Duncan Dowson,et al.  The role of counterface imperfections in the wear of polyethylene , 1987 .

[12]  C. Ranawat,et al.  Review Article: Osteolysis After Total Knee Arthroplasty , 2007 .

[13]  J. Davim,et al.  Tribological Comparative Study of Conventional and Composite Materials in Biomedical Applications , 2002 .

[14]  I. Clarke,et al.  Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation , 2006, Acta orthopaedica.

[15]  Y.-M. Deng,et al.  Supporting design decision-making when applying materials in combination , 2007 .

[16]  H. Rack,et al.  Titanium alloys in total joint replacement--a materials science perspective. , 1998, Biomaterials.

[17]  W. Harmsen,et al.  Revision Total Knee Arthroplasty With Modular Cemented Stems , 2007 .

[18]  F. Cui,et al.  A simple method to prepare calcium phosphate coatings on Ti6Al4V , 1997, Journal of materials science. Materials in medicine.

[19]  J. Paulo Davim,et al.  Evaluation of Tribological Behaviour of Polymeric Materials for Hip Prostheses Application , 2001 .

[20]  David F. Williams On the nature of biomaterials. , 2009, Biomaterials.

[21]  K. L. Edwards Towards an improved development process for new hip prostheses , 2008 .

[22]  M. Laberge,et al.  UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation , 2008 .

[23]  A. Wang,et al.  Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement , 1998 .

[24]  Peter Greil,et al.  Functionally graded materials for biomedical applications , 2003 .

[25]  M. Raimondi,et al.  The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating. , 2000, Biomaterials.

[26]  A Unsworth,et al.  Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials , 2009, Journal of materials science. Materials in medicine.

[27]  J. Simões,et al.  Relationship of design features of stemmed tibial knee prosthesis with stress shielding and end-of-stem pain , 2009 .

[28]  Chockalingam,et al.  The outcome of cemented vs. cementless fixation of a femoral component in total knee replacement (TKR) with the identification of radiological signs for the prediction of failure. , 2000, The Knee.

[29]  A. Amirfazli,et al.  Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements. , 2007, Journal of biomechanics.

[30]  L. Topoleski,et al.  Third-body wear of cobalt-chromium-molybdenum implant alloys initiated by bone and poly(methyl methacrylate) particles. , 2000, Journal of biomedical materials research.

[31]  A. van Kampen,et al.  Distal femoral bone mineral density decreases following patellofemoral arthroplasty: 1-year follow-up study of 14 patients , 2010, BMC musculoskeletal disorders.

[32]  M. Ashby,et al.  Cellular solids: Structure & properties , 1988 .

[33]  Mikio Iwamoto,et al.  PE wear in ceramic/PE bearing surface in total knee arthroplasty: Clinical experiences of more than 24 years , 2006 .

[34]  P. J. Gregg,et al.  A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacement , 2002 .

[35]  T. Brown,et al.  Scratching vulnerability of conventional vs highly cross-linked polyethylene liners because of large embedded third-body particles. , 2012, The Journal of arthroplasty.

[36]  Kevin L. Edwards,et al.  Materials influence on design: A decade of development , 2011 .

[37]  W. Ortega-Lara,et al.  Mechanical properties and apatite-forming ability of PMMA bone cements , 2009 .

[38]  S. Kurtz,et al.  PEEK biomaterials in trauma, orthopedic, and spinal implants. , 2007, Biomaterials.

[39]  P. Christel,et al.  Wear analysis of retrieved alumina heads and sockets of hip prostheses. , 1989, Journal of Biomedical Materials Research.

[40]  E. Axinte Metallic glasses from “alchemy” to pure science: Present and future of design, processing and applications of glassy metals , 2012 .

[41]  J. Paulo Davim,et al.  Effect of carbon fibre reinforcement in the frictional behaviour of Peek in a water lubricated environment , 2001 .

[42]  C. Rorabeck,et al.  Wear and osteolysis around total knee arthroplasty. , 2007, The Journal of the American Academy of Orthopaedic Surgeons.

[43]  A. Unsworth,et al.  Tribological assessment of a flexible carbon-fibre-reinforced poly(ether—ether—ketone) acetabular cup articulating against an alumina femoral head , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[44]  V. Jansson,et al.  Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo. , 2010, Acta biomaterialia.

[45]  J. Liau,et al.  Osteolysis in Failed Total Knee Arthroplasty: A Comparison of Mobile-Bearing and Fixed-Bearing Knees , 2002, The Journal of bone and joint surgery. American volume.

[46]  Johan Bellemans,et al.  Total knee arthroplasty: a guide to get better performance , 2005 .

[47]  Aiguo Wang,et al.  Mechanical properties and fatigue performance of crosslinked polyethylene in total knee applications , 2003 .

[48]  B. Bal,et al.  Primary Total Knee Replacement with a Zirconia Ceramic Femoral Component , 2005 .

[49]  Ali Jahan,et al.  Material selection for femoral component of total knee replacement using comprehensive VIKOR , 2011 .

[50]  Mahmoud Nemat-Alla,et al.  Reduction of thermal stresses by developing two-dimensional functionally graded materials , 2003 .

[51]  M. Lee,et al.  Ceramic Femoral Prosthesis in TKA — Present and Future , 2007 .

[52]  F. Migliavacca,et al.  Biomedical Applications of Shape Memory Alloys , 2011 .

[54]  P. Sharkey,et al.  Why Are Total Knee Arthroplasties Failing Today? , 2002 .

[55]  J. Rand,et al.  Cemented long-stem revision total knee arthroplasty. , 2003, Clinical orthopaedics and related research.

[56]  G. H. van Lenthe,et al.  Stemmed femoral knee prostheses , 2002 .

[57]  R. Bader,et al.  Ceramic knee endoprostheses: reality or future? , 2006 .

[58]  C. Engh,et al.  Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. , 2005, The Journal of bone and joint surgery. American volume.

[59]  H. S. Hedia Design of functionally graded dental implant in the presence of cancellous bone. , 2005, Journal of biomedical materials research. Part B, Applied biomaterials.

[60]  R. Narayan,et al.  The use of functionally gradient materials in medicine , 2006 .

[61]  J. Galante,et al.  Problems With Cementless Total Knee Arthroplasty at 11 Years Followup , 2001, Clinical orthopaedics and related research.

[62]  K. Lai,et al.  Early mechanical complications of a multidirectional mobile-bearing total knee replacement. , 2011, The Journal of bone and joint surgery. British volume.

[63]  L. Claes,et al.  Osseointegration of alumina with a bioactive coating under load-bearing and unloaded conditions. , 2005, Biomaterials.

[64]  Farzam Farahmand,et al.  Aseptic loosening of femoral components – A review of current and future trends in materials used , 2012 .

[65]  H. Skinner Ceramics in Total Joint Surgery: The Pros and Cons , 2006 .

[66]  J. Chevalier,et al.  Ceramics for medical applications: A picture for the next 20 years , 2009 .

[67]  Eugene Ryshkewitch,et al.  Compression Strength of Porous Sintered Alumina and Zirconia , 1953 .

[68]  R. Bourne,et al.  Wear Performance of Ultra-High Molecular Weight Polyethylene on Oxidized Zirconium Total Knee Femoral Components , 2001, The Journal of bone and joint surgery. American volume.

[69]  Günther Heimke,et al.  Knee arthoplasty: recently developed ceramics offer new solutions. , 2002, Biomaterials.

[70]  T. Pandorf,et al.  Advanced Testing of Ceramic Femoral Knee Components , 2007 .

[71]  M H Stone,et al.  Some factors affecting the strength of the cement-metal interface. , 1989, The Journal of bone and joint surgery. British volume.

[72]  J W Goodfellow,et al.  Unicompartmental Oxford Meniscal knee arthroplasty. , 1987, The Journal of arthroplasty.

[73]  W. Harmsen,et al.  Revision total knee arthroplasty with modular cemented stems: long-term follow-up. , 2007, The Journal of arthroplasty.

[74]  C. Bünger,et al.  A review of ceramic coatings for implant fixation. , 1999, Journal of long-term effects of medical implants.

[75]  C. Ranawat,et al.  Total Condylar Knee Replacement: A 20-Year Followup Study , 2001, Clinical orthopaedics and related research.

[76]  H. Oonishi,et al.  Surface Analysis on Retrieved Ceramic Total Knee Prosthesis , 2001 .

[77]  S. Affatato,et al.  Implant fixation in knee replacement: preliminary in vitro comparison of ceramic and metal cemented femoral components. , 2009, The Knee.

[78]  A. Lombardi,et al.  Evolution of tibial fixation in total knee arthroplasty. , 2007, The Journal of arthroplasty.

[79]  A. Essner,et al.  A highly crosslinked UHMWPE for CR and PS total knee arthroplasties. , 2008, The Journal of arthroplasty.

[80]  A Unsworth,et al.  The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[81]  J. Yang,et al.  Hybrid component fixation in total knee arthroplasty: minimum of 10-year follow-up study. , 2007, The Journal of arthroplasty.

[82]  Y. Ishii,et al.  Is bone density in the distal femur affected by use of cement and by femoral component design in total knee arthroplasty? , 1999, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[83]  N Verdonschot,et al.  Finite Element Analysis of the Long-Term Fixation Strength of Cemented Ceramic Cups , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[84]  R. Huiskes,et al.  Stemmed femoral knee prostheses: effects of prosthetic design and fixation on bone loss. , 2002, Acta orthopaedica Scandinavica.

[85]  P J Gregg,et al.  A randomised controlled trial of cemented versus cementless press-fit condylar total knee replacement: 15-year survival analysis. , 2007, The Journal of bone and joint surgery. British volume.

[86]  B. Bal,et al.  Ceramic Materials in Total Joint Arthroplasty , 2006 .

[87]  J. Tamura,et al.  Bioactive bone cements containing nano-sized titania particles for use as bone substitutes. , 2005, Biomaterials.

[88]  V. Jansson,et al.  Wear of contemporary total knee replacements--a knee simulator study of six current designs. , 2009, Clinical biomechanics.

[89]  K. Katti,et al.  Biomaterials in total joint replacement. , 2004, Colloids and surfaces. B, Biointerfaces.

[90]  N. Verdonschot,et al.  A sliding stem in revision total knee arthroplasty provides stability and reduces stress shielding , 2010, Acta orthopaedica.