Dynamic Studies of Brain Tumors by the Use of Digital Fluoroscopy

By the use of an expanded X-ray video chain and contrast medium injection, brain tumors can be set off against cerebral tissue. Based on a theoretical model, such weak contrasts behind a strongly absorbing bony structure can be visualized with a nontomographic procedure by massive noise reduction and specialized subtraction technique using an X-ray system optimized to iodine contrasts. During a period of examination, four image series are taken and stored. Dynamic studies concerning redistribution of contrast medium in the intravasal and extravasal spaces of brain tissue and tumor tissue are obtained by the subtraction of stored images. Visualization of the blood flow dynamics has helped to improve internal tumor differentiation and to demarcate the lesion better, especially from a brain edema. As in fluoroscopy, the X-ray tube is operated at a low current so that the skin dose at the radiation entry port amounts to less than 0.4 R for an image series. How practicable this method is in complementing computed tomography is demonstrated by studies of two patients (from a total of 20 patients examined) with a glioblastoma and a third-degree astrocytoma.

[1]  R A Kruger,et al.  Dynamic tomographic digital subtraction angiography using temporal filtration. , 1983, Radiology.

[2]  R A Kruger,et al.  Digital subtraction angiography using a temporal bandpass filter: initial clinical results. , 1982, Radiology.

[3]  S. Riederer Performance of X-Ray Imaging Systems Applied to Intravenous Angiography , 1982, IEEE Transactions on Medical Imaging.

[4]  Stephen J Riederer,et al.  Iodine Sensitivity Of Digital Imaging Systems , 1981, Other Conferences.

[5]  R A Kruger,et al.  Digital subtraction angiography using a temporal bandpass filter: associated patient motion properties. , 1982, Radiology.

[6]  Hans Roehrig,et al.  INTRAVENOUS ANGIOGRAPHY USING DIGITAL VIDEO SUBTRACTION , 1980 .

[7]  Robert A. Kruger,et al.  Digital Angiography Using a Matched Filter , 1982, IEEE Transactions on Medical Imaging.

[8]  S. Riederer,et al.  Digital K-edge subtraction radiography. , 1977, Radiology.

[9]  R A Kruger,et al.  Computerized arteriography of the cerebrovascular system: its use with intravenous administration of contrast material. , 1981, Archives of surgery.

[10]  B. Drayer,et al.  Dynamic Computed Tomography Study of the Brain , 1979, Advances in neurology.

[11]  R. Coleman,et al.  An extravascular component of contrast enhancement in cranial computed tomography. Part I. The tissue-blood ratio of contrast enhancement. , 1975, Radiology.

[12]  P. Fischer,et al.  Zum Auflösungsvermögen der digitalen Videosubtraktionsangiographie (DVSA) , 1983 .

[13]  E. Hoffman,et al.  Attenuation coefficients of various body tissues, fluids, and lesions at photon energies of 18 to 136 keV. , 1975, Radiology.

[14]  D. Norman,et al.  Comparative efficacy of contrast agents in computed tomography scanning of the brain. , 1978, Journal of computer assisted tomography.

[15]  P R Moran A physical statistics theory for detectability of target signals in noisy images. I. Mathematical background, empirical review, and development of theory. , 1982, Medical physics.

[16]  Robert A. Kruger,et al.  Time domain filtering using computerized fluoroscopy--intravenous angiography applications , 1981, Other Conferences.

[17]  W. Chilcote,et al.  Digital subtraction angiography of the carotid arteries: a comparative study in 100 patients. , 1981, Radiology.

[18]  E. A. Stevens,et al.  Quantitative aspects of contrast enhancement in cranial computed tomography. , 1978, Radiology.

[19]  R A Kruger,et al.  Computerized fluoroscopy: digital subtraction for intravenous angiocardiography and arteriography. , 1980, AJR. American journal of roentgenology.

[20]  D. Kuhl,et al.  Pitfalls in the measurement of cerebral blood volume with computed tomography. , 1976, Radiology.

[21]  Thomas F. Meaney,et al.  Digital Subtraction Angiography Of The Human Cardiovascular System , 1980, Other Conferences.

[22]  R. Lewander Contrast Enhancement with Time in Gliomas , 1979, Acta radiologica: diagnosis.

[23]  M Danos,et al.  Image information content and patient exposure. , 1978, Medical physics.

[24]  Robert A. Kruger,et al.  A Digital Video Image Processor for Real-Time X-Ray Subtraction Imaging , 1978 .

[25]  K. Reiss Scattered radiation and characteristic film curve. , 1963, Radiology.

[26]  M. Capp,et al.  Intracranial applications of digital intravenous subtraction angiography. , 1982, Radiology.

[27]  S J Riederer,et al.  The application of matched filtering to contrast material dose reduction in digital subtraction angiography. , 1983, Radiology.

[28]  R. Coleman,et al.  An extravascular component of contrast enhancement in cranial computed tomography. Part II. Contrast enhancement and the blood-tissue barrier. , 1975, Radiology.

[29]  S J Riederer,et al.  Real-time digital K-edge subtraction fluoroscopy. , 1979, Investigative radiology.

[30]  W. Lanksch,et al.  Computertomographie intrakranieller Tumoren aus klinischer Sicht , 1981 .

[31]  C A Mistretta,et al.  Digital angiography: a perspective. , 1981, Radiology.

[32]  S J Riederer,et al.  Work in progress: the application of temporal filtering techniques to hybrid subtraction in digital subtraction angiography. , 1983, Radiology.

[33]  H Roehrig,et al.  Intravenous angiography using digital video subtraction: x-ray imaging system. , 1980, AJR. American journal of roentgenology.