Effects of mobile phone use on specific intensive care unit devices

Background and Aims: To observe the effects of mobile phone use in the vicinity of medical devices used in a critical care setting. Subjects and Methods: Electromagnetic interference (EMI) was tested by using two types of mobile phones – GSM and CDMA. Mobile phones were placed at a distance of one foot from three medical devices – syringe pump, mechanical ventilator, and the bedside monitor – in switch off, standby, and talking modes of the phone. Medical devices were observed for any interference caused by the electromagnetic radiations (EMR) from the mobile phones. Results: Out of the three medical devices that were tested, EMI occurred while using the mobile phone in the vicinity of the syringe pump, in the ‘talk mode.’ The mean variation observed in the calculated and delivered volume of the syringe pump was 2.66 ml. Mechanical ventilator did not show any specific adverse effects with mobile phone use in the one-foot vicinity. No other adverse effects or unexplained malfunctions or shutdown of the syringe pump, mechanical ventilator, or the bedside monitor was noted during the study period of 36 hours. Conclusion: EMI from mobile phones have an adverse effect on the medical devices used in critical care setup. They should be used at least one foot away from the diameter of the syringe pump.

[1]  D B Stroud,et al.  Mobile telephones interfere with medical electrical equipment. , 1994, Australasian physical & engineering sciences in medicine.

[2]  R Tobisch,et al.  Mobile phones in hospitals. , 1999, Biomedical instrumentation & technology.

[3]  R. Van der Togt,et al.  Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment. , 2008, JAMA.

[4]  Douglas R Small,et al.  Use of mobile phones in hospital , 2003, The Lancet.

[5]  Nathan Lawrentschuk,et al.  Mobile phone interference with medical equipment and its clinical relevance: a systematic review , 2004, The Medical journal of Australia.

[6]  Giovanni Calcagnini,et al.  ELECTROMAGNETIC INTERFERENCE WITH INFUSION PUMPS FROM GSM MOBILE PHONES , 2004, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference.

[7]  J. Boyle Wireless technologies and patient safety in hospitals. , 2006, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[8]  K. Nelson,et al.  Developing a comprehensive electronic adverse event reporting system in an academic health center. , 2002, The Joint Commission journal on quality improvement.