Detection and classification of gaseous sulfur compounds by solid electrolyte cyclic voltammetry of cermet sensor array.

Electrochemical sensors composed of a ceramic-metallic (cermet) solid electrolyte are used for the detection of gaseous sulfur compounds SO(2), H(2)S, and CS(2) in a study involving 11 toxic industrial chemical (TIC) compounds. The study examines a sensor array containing four cermet sensors varying in electrode-electrolyte composition, designed to offer selectivity for multiple compounds. The sensors are driven by cyclic voltammetry to produce a current-voltage profile for each analyte. Raw voltammograms are processed by background subtraction of clean air, and the four sensor signals are concatenated to form one vector of points. The high-resolution signal is compressed by wavelet transformation and a probabilistic neural network is used for classification. In this study, training data from one sensor array was used to formulate models which were validated with data from a second sensor array. Of the 11 gases studied, 3 that contained sulfur produced the strongest responses and were successfully analyzed when the remaining compounds were treated as interferents. Analytes were measured from 10 to 200% of their threshold-limited value (TLV) according to the 8-h time weighted average (TWA) exposure limits defined by the National Institute of Occupational Safety and Health (NIOSH). True positive classification rates of 93.3, 96.7, and 76.7% for SO(2), H(2)S, and CS(2), respectively, were achieved for prediction of one sensor unit when a second sensor was used for modeling. True positive rates of 83.3, 90.0, and 90.0% for SO(2), H(2)S, and CS(2), respectively, were achieved for the second sensor unit when the first sensor unit was used for modeling. Most of the misclassifications were for low concentration levels (such 10-25% TLV) in which case the compound was classified as clean air. Between the two sensors, the false positive rates were 2.2% or lower for the three sulfur compounds, 0.9% or lower for the interferents (eight remaining analytes), and 5.8% or lower for clean air. The cermet sensor arrays used in this analysis are rugged, low cost, reusable, and show promise for multiple compound detection at parts-per-million (ppm) levels.

[1]  Kevin J. Johnson,et al.  A novel chemical detector using cermet sensors and pattern recognition methods for toxic industrial chemicals , 2006 .

[2]  Kevin J. Johnson,et al.  Monitoring Diesel Fuel Degradation by Gas Chromatography−Mass Spectroscopy and Chemometric Analysis , 2004 .

[3]  Dae-Sik Lee,et al.  Environmental gas sensors , 2001 .

[4]  Corrado Di Natale,et al.  Pattern recognition in gas sensing: well-stated techniques and advances , 1995 .

[5]  Richard Kramer,et al.  Chemometric Techniques For Quantitative Analysis , 1998 .

[6]  Ingemar Lundström,et al.  Approaches and mechanisms to solid state based sensing , 1996 .

[7]  N. White,et al.  Thick-film sensors : past, present and future , 1997 .

[8]  Tom Artursson,et al.  Wavelet transform of electronic tongue data , 2002 .

[9]  Hui Ding,et al.  High performance of gas identification by wavelet transform-based fast feature extraction from temperature modulated semiconductor gas sensors , 2005 .

[10]  K. Toda,et al.  Micro-gas analysis system μGAS comprising a microchannel scrubber and a micro-fluorescence detector for measurement of hydrogen sulfide , 2004 .

[11]  W. Carey,et al.  Multivariate sensor arrays as industrial and environmental monitoring systems , 1994 .

[12]  J. Poston,et al.  Interaction of hydrogen sulfide with Zr0.92Y0.08O2−δ/40% Ni cermet , 2005 .

[13]  Frederick W. Williams,et al.  Real-time classification performance and failure mode analysis of a physical/chemical sensor array and a probabilistic neural network , 2001 .

[14]  F. J. Dudek,et al.  Gas microsensors using cyclic voltammetry with a cermet electrochemical cell , 1997 .

[15]  Antoni Nowakowski,et al.  Properties of a lithium solid electrolyte gas sensor based on reaction kinetics , 2005 .

[16]  Jason P. Trembly,et al.  Effects of coal syngas and H2S on the performance of solid oxide fuel cells: Single-cell tests , 2006 .

[17]  Peter C. Hauser,et al.  Amperometric sensing in the gas-phase , 2005 .

[18]  A. Walmsley,et al.  Evaluation of chemometric techniques for the identification and quantification of solvent mixtures using a thin-film metal oxide sensor array , 1991 .

[19]  Ricardo Gutierrez-Osuna,et al.  The how and why of electronic noses , 1998 .

[20]  Susan L. Rose-Pehrsson,et al.  Training set optimization methods for a probabilistic neural network , 2004 .

[21]  Frederick W. Williams,et al.  Multi-criteria fire detection systems using a probabilistic neural network , 2000 .

[22]  M Soliman Selim,et al.  Room temperature sensitivity of (SnO2–ZrO2) sol–gel thin films , 2000 .

[23]  M. Koudelka-Hep,et al.  Electronic noses – A mini-review , 1999 .

[24]  Meilin Liu,et al.  Identification of nickel sulfides on Ni-YSZ cermet exposed to H2 fuel containing H2S using Raman spectroscopy , 2006 .

[25]  F. J. Dudek,et al.  Cyclic voltammetry applied to an oxygen-ion-conducting solid electrolyte as an active electrocatalytic gas sensor , 1996 .

[26]  Y. Matsuzaki,et al.  The Poisoning Effect of Sulfur-Containing Impurity Gas on a SOFC Anode: Part I , 2000 .

[27]  M. C. Vogt,et al.  CO2 sensing mechanisms of an electrocatalytic sensor based on a tungsten-stabilized bismuth oxide solid electrolyte and cyclic voltammetry measurement techniques , 2005 .

[28]  S. Rose-Pehrsson,et al.  Improved probabilistic neural network algorithm for chemical sensor array pattern recognition. , 1999, Analytical chemistry.

[29]  Eduard Llobet,et al.  Wavelet transform-based fast feature extraction from temperature modulated semiconductor gas sensors , 2002 .

[30]  A. Bateman,et al.  Adjacent channel power and error-vector magnitude performance of reduced complexity CALLUM systems , 1999 .

[31]  S. Rose-Pehrsson,et al.  A comparison study of chemical sensor array pattern recognition algorithms , 1999 .

[32]  N. Yamazoe,et al.  Environmental gas sensing , 1994 .

[33]  Norio Miura,et al.  Sensing characteristics and mechanisms of hydrogen sulfide sensor using stabilized zirconia and oxide sensing electrode , 1996 .

[34]  Thomas E. Fuja,et al.  A comparative study of signal processing techniques for clustering microsensor data (a first step towards an artificial nose) , 1997 .

[35]  Jordi Riu,et al.  Nanosensors in environmental analysis. , 2006, Talanta.

[36]  M. C. Vogt,et al.  A trainable cermet gas microsensor technology using cyclic voltammetry and neural networks , 1996 .

[37]  Richard G. Brereton,et al.  Introduction to multivariate calibration in analytical chemistry , 2000 .

[38]  James R. McDonald,et al.  Using physics-based modeler outputs to train probabilistic neural networks for unexploded ordnance (UXO) classification in magnetometry surveys , 2001, IEEE Trans. Geosci. Remote. Sens..

[39]  Gregory P. Harmer,et al.  Detection of chemical warfare agents using nanostructured metal oxide sensors , 2005 .

[40]  Kevin J. Johnson,et al.  Pattern recognition of jet fuels: comprehensive GC×GC with ANOVA-based feature selection and principal component analysis , 2002 .