Validation of delay‐multiply‐and‐standard‐deviation weighting factor for improved photoacoustic imaging of sentinel lymph node

Delay-and-sum (DAS) is one of the most common algorithms used to construct the photoacoustic images due to its low complexity. However, it results in images with high sidelobes and low resolution. Delay-and-standard-deviation (DASD) weighting factor can improve the contrast of the images compared to DAS. However, it still suffers from high sidelobes. In this work, a new weighting factor, named delay-multiply-and-standard-deviation (DMASD) is introduced to enhance the contrast of the reconstructed images compared to other mentioned methods. In the proposed method, the SD of the mutual multiplied delayed signals are calculated, normalized and multiplied to DAS beamformed data. The results show that DMASD improves the signal-to-noise-ratio about 19.29 and 7.3 dB compared to DAS and DASD, respectively, for in vivo imaging of the sentinel lymph node. Moreover, the contrast ratio is improved by the DMASD about 23.61 and 10.81 dB compared to DAS and DASD, respectively.

[1]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[2]  Lihong V. Wang,et al.  Single-breath-hold photoacoustic computed tomography of the breast , 2018, Nature Communications.

[3]  Lihong V. Wang,et al.  Small-Animal Whole-Body Photoacoustic Tomography: A Review , 2014, IEEE Transactions on Biomedical Engineering.

[4]  Manojit Pramanik,et al.  Non‐invasive sentinel lymph node mapping and needle guidance using clinical handheld photoacoustic imaging system in small animal , 2018, Journal of biophotonics.

[5]  Manojit Pramanik,et al.  Hand‐held, clinical dual mode ultrasound ‐ photoacoustic imaging of rat urinary bladder and its applications , 2018, Journal of biophotonics.

[6]  Junjie Yao,et al.  Single-impulse Panoramic Photoacoustic Computed Tomography of Small-animal Whole-body Dynamics at High Spatiotemporal Resolution , 2017, Nature Biomedical Engineering.

[7]  Jesse V. Jokerst,et al.  The double-stage delay-multiply-and-sum image reconstruction method improves imaging quality in a LED-based photoacoustic array scanner , 2018, Photoacoustics.

[8]  Lihong V. Wang,et al.  High-resolution photoacoustic tomography of resting-state functional connectivity in the mouse brain , 2013, Proceedings of the National Academy of Sciences.

[9]  Paul Kumar Upputuri,et al.  Recent advances toward preclinical and clinical translation of photoacoustic tomography: a review , 2016, Journal of biomedical optics.

[10]  Lihong V. Wang,et al.  In vivo three-dimensional photoacoustic imaging based on a clinical matrix array ultrasound probe. , 2012, Journal of biomedical optics.

[11]  Lihong V. Wang,et al.  Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs , 2012, Science.

[12]  Jesse V Jokerst,et al.  Photoacoustic Tomography Detects Early Vessel Regression and Normalization During Ovarian Tumor Response to the Antiangiogenic Therapy Trebananib , 2015, The Journal of Nuclear Medicine.

[13]  Lihong V. Wang,et al.  Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection in Patients with Breast Cancer , 2015, Scientific Reports.

[14]  Giovanni Magenes,et al.  The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical Imaging , 2015, IEEE Transactions on Medical Imaging.

[15]  Ali Mahloojifar,et al.  Linear-array photoacoustic imaging using minimum variance-based delay multiply and sum adaptive beamforming algorithm , 2018, Journal of biomedical optics.

[16]  Manojit Pramanik,et al.  Efficient nonlinear beamformer based on P’th root of detected signals for linear-array photoacoustic tomography: application to sentinel lymph node imaging , 2018, Journal of biomedical optics.

[17]  Jian Li,et al.  Multifrequency Microwave-Induced Thermal Acoustic Imaging for Breast Cancer Detection , 2007, IEEE Transactions on Biomedical Engineering.

[18]  Moein Mozaffarzadeh,et al.  Photoacoustic image formation based on sparse regularization of minimum variance beamformer. , 2018, Biomedical optics express.

[19]  Chulhong Kim,et al.  Sentinel lymph nodes and lymphatic vessels: noninvasive dual-modality in vivo mapping by using indocyanine green in rats--volumetric spectroscopic photoacoustic imaging and planar fluorescence imaging. , 2010, Radiology.

[20]  Ali Mahloojifar,et al.  Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging , 2018, IEEE Transactions on Biomedical Engineering.

[21]  Jesse V. Jokerst,et al.  The development and characterization of a novel yet simple 3D printed tool to facilitate phantom imaging of photoacoustic contrast agents , 2017, Photoacoustics.

[22]  Manojit Pramanik,et al.  Eigenspace-Based Minimum Variance Combined With Delay Multiply and Sum Beamformer: Application to Linear-Array Photoacoustic Imaging , 2018, IEEE Journal of Selected Topics in Quantum Electronics.

[23]  Liang Song,et al.  Delay-multiply-and-sum-based synthetic aperture focusing in photoacoustic microscopy , 2016, Journal of biomedical optics.

[24]  Stanislav Emelianov,et al.  Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging , 2014 .

[25]  Yong Zhou,et al.  Tutorial on photoacoustic tomography , 2016, Journal of biomedical optics.

[26]  S. Emelianov,et al.  Photoacoustic Imaging for Cancer Detection and Staging. , 2013, Current molecular imaging.

[27]  Changhui Li,et al.  Three-dimensional photoacoustic imaging via scanning a one dimensional linear unfocused ultrasound array. , 2017, Optics express.

[28]  Eigil Samset,et al.  Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[29]  Ali Mahloojifar,et al.  Double-Stage Delay Multiply and Sum Beamforming Algorithm Applied to Ultrasound Medical Imaging. , 2017, Ultrasound in medicine & biology.

[30]  Zhifei Shi,et al.  Dynamic characteristics of an axially polarized multilayer piezoelectric/elastic composite cylindrical transducer , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  A. Austeng,et al.  Benefits of minimum-variance beamforming in medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  Lihong V. Wang,et al.  A practical guide to photoacoustic tomography in the life sciences , 2016, Nature Methods.