Parameter Estimation of Three-Phase Transformer Models for Low-Frequency Transient Studies From Terminal Measurements

This paper introduces a three-phase reversible transformer model for the study of low-frequency transients. The model topology is obtained from the direct application of the principle of duality by drawing basic circuit elements on top of the transformer frame. The model parameters are obtained from terminal and physical size measurements as well as the characteristics of the iron core. The implementation of the model is based on standard drag-and-drop circuit elements available in electric circuit simulation programs. The model is validated with inrush current and normal open circuit laboratory measurements. The main advantage of this model is that the parameters remain the same for the simulation of different operating conditions from all terminals. This is true for transients involving deep saturation, normal loading operation, or open circuit.

[1]  B.A. Mork,et al.  Transformer modeling for low- and mid-frequency transients - a review , 2005, IEEE Transactions on Power Delivery.

[2]  J. A. Martinez,et al.  Duality Derived Transformer Models for Low-Frequency Electromagnetic Transients—Part I: Topological Models , 2016, IEEE Transactions on Power Delivery.

[3]  E. Cardelli,et al.  Theoretical Considerations of Magnetic Hysteresis and Transformer Inrush Current , 2009, IEEE Transactions on Magnetics.

[4]  F. de Leon,et al.  Complete transformer model for electromagnetic transients , 1994 .

[5]  C. D. Gelatt,et al.  Optimization by Simulated Annealing , 1983, Science.

[6]  C.M. Arturi Transient Simulation and Analysis of Three-Phase Five-Limb Step-Up Transformer Following an Out-of-Phase Synchronization , 1991, IEEE Power Engineering Review.

[7]  E. Cardelli,et al.  Prediction and Control of Transformer Inrush Currents , 2015, IEEE Transactions on Magnetics.

[8]  Nicola Chiesa,et al.  Implementation of Inverse Hysteresis Model Into EMTP—Part II: Dynamic Model , 2015, IEEE Transactions on Power Delivery.

[9]  N Chiesa,et al.  Transformer Model for Inrush Current Calculations: Simulations, Measurements and Sensitivity Analysis , 2010, IEEE Transactions on Power Delivery.

[10]  Gholamhossein Shirkoohi,et al.  Dependence of Magnetization Near Saturation on Alloying Content in Ferromagnetic Steel , 2015, IEEE Transactions on Magnetics.

[11]  Antonios G. Kladas,et al.  Analysis of Transformers Working Under Heavily Saturated Conditions in Grid-Connected Renewable-Energy Systems , 2012, IEEE Transactions on Industrial Electronics.

[12]  B.A. Mork,et al.  Parameter determination for modeling system transients-Part III: Transformers , 2005, IEEE Transactions on Power Delivery.

[13]  J. Faiz,et al.  Inrush Current Modeling in a Single-Phase Transformer , 2010, IEEE Transactions on Magnetics.

[14]  M. Sumner,et al.  Characteristics of Jiles–Atherton Model Parameters and Their Application to Transformer Inrush Current Simulation , 2008, IEEE Transactions on Magnetics.

[15]  T. Tran-Quoc,et al.  An efficient non linear transformer model and its application to ferroresonance study , 1995 .

[16]  S. S. Venkata,et al.  A three-phase three-winding core-type transformer model for low-frequency transient studies , 1997 .

[17]  J.A. Martinez,et al.  Parameter determination for modeling system transients - Part IV: rotating machines , 2005, IEEE Transactions on Power Delivery.

[18]  Bruce A. Mork,et al.  Five-legged wound-core transformer model: derivation, parameters, implementation and evaluation , 1999 .

[19]  Francisco de Leon,et al.  Accurate Measurement of the Air-Core Inductance of Iron-Core Transformers With a Non-Ideal Low-Power Rectifier , 2014, IEEE Transactions on Power Delivery.

[20]  Francisco De Leon,et al.  Dual three-winding transformer equivalent circuit matching leakage measurements , 2009, 2009 IEEE Power & Energy Society General Meeting.

[21]  Joydeep Mitra,et al.  Hybrid Transformer Model for Transient Simulation—Part II: Laboratory Measurements and Benchmarking , 2007 .

[22]  Dantam K. Rao,et al.  Effective Use of Magnetization Data in the Design of Electric Machines With Overfluxed Regions , 2015, IEEE Transactions on Magnetics.

[23]  Sergey E. Zirka,et al.  Accounting for the Influence of the Tank Walls in the Zero-Sequence Topological Model of a Three-Phase, Three-Limb Transformer , 2014, IEEE Transactions on Power Delivery.

[24]  Francisco de Leon,et al.  Dual Reversible Transformer Model for the Calculation of Low-Frequency Transients , 2013, IEEE Transactions on Power Delivery.

[25]  Steven D. Mitchell,et al.  Initial parameter estimates and constraints to support gray box modeling of power transformers , 2014 .

[26]  A. Narang,et al.  Topology based magnetic model for steady-state and transient studies for three-phase core type transformers , 1994 .

[27]  Joydeep Mitra,et al.  Hybrid Transformer Model for Transient Simulation—Part I: Development and Parameters , 2007, IEEE Transactions on Power Delivery.

[28]  C. M. Arturi,et al.  Topology-Correct Reversible Transformer Model , 2012, IEEE Transactions on Power Delivery.

[29]  Francisco de Leon,et al.  Experimentally Validated Reversible Single-Phase Multiwinding Transformer Model for the Accurate Calculation of Low-Frequency Transients , 2015, IEEE Transactions on Power Delivery.

[30]  Afshin Rezaei-Zare,et al.  Enhanced Transformer Model for Low- and Mid-Frequency Transients—Part II: Validation and Simulation Results , 2015, IEEE Transactions on Power Delivery.

[31]  Afshin Rezaei-Zare,et al.  Enhanced Transformer Model for Low- and Mid-Frequency Transients—Part I: Model Development , 2015, IEEE Transactions on Power Delivery.

[32]  A. S. Morched,et al.  Modeling and analysis guidelines for slow transients. III. The study of ferroresonance , 2000 .

[33]  R. Yacamini,et al.  Transformer inrush calculations using a coupled electromagnetic model , 1994 .