Semiquantitative, bar code version of immunochromatographic assay system for human serum albumin as model analyte.

An immunochromatographic assay system was devised that can express the concentration ranges of analyte (e.g., urinary human serum albumin) as distinct numbers of the ladder bar (bar coding) for semiquantitation. We constructed a model system consisting of five membrane pad strips partially superimposed in a length. Upon wicking of sample from the bottom, the medium dissolved two different biotinylated species, antibody to the analyte and conjugates of the antibody with colloidal gold, and antigen-antibody reactions took place in the hollow space of the glass fiber membrane. After eliminating unreacted biotinylated molecules at the next strip with an immobilized albumin, the immune complexes were transferred to the pad with streptavidin immobilized in a ladder bar pattern. Analytical conditions here were set for competition between the two biotinylated species for the streptavidin binding sites. The degree of such competition was proportional to the analyte concentration and, consequently, the bar signal number was elevated as the concentration increased. Under optimal conditions for sensitivity, the analytical system responded to the analyte doses at between 30 and 120 mg/dL by producing different bar codes within 5 min.

[1]  O. Wolfbeis,et al.  Microalbuminuria and borderline-increased albumin excretion determined with a centrifugal analyzer and the Albumin Blue 580 fluorescence assay. , 1997, Clinical chemistry.

[2]  U. Stenman,et al.  Streptavidin-biotin based time-resolved immunofluorometric assay for direct measurement of high concentrations of human chorionic gonadotropin (hCG). , 1994, Journal of immunological methods.

[3]  S. H. Lee,et al.  Development of rapid one-step immunochromatographic assay. , 2000, Methods.

[4]  M P Laitinen,et al.  Thin-layer affinity chromatography in analysis of protein-ligand affinity. , 1996, Analytical biochemistry.

[5]  S. Ichiyama,et al.  Evaluation of immunochromatographic assay systems for rapid detection of hepatitis B surface antigen and antibody, Dainascreen HBsAg and Dainascreen Ausab , 1996, Journal of clinical microbiology.

[6]  S. Paek,et al.  Performance Control Strategies of One-Step Immuno-Chromatographic Assay System for Salmonella Typhimurium , 1999 .

[7]  Chew Theng Sang,et al.  Clinical Evaluation of a Rapid Immunochromatographic Test for the Diagnosis of Dengue Virus Infection , 1998, Clinical Diagnostic Laboratory Immunology.

[8]  S. Paek,et al.  Immunochromatographic membrane strip assay system for a single-class plasma lipoprotein cholesterol, exemplified by high-density lipoprotein cholesterol measurement. , 1999, Biotechnology and bioengineering.

[9]  M. M. Bradford A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. , 1976, Analytical biochemistry.

[10]  Chulhyun Kim,et al.  Association of microalbuminuria and atherosclerotic risk factors in non-diabetic subjects in Korea. , 1998, Diabetes research and clinical practice.

[11]  S. Nilsson,et al.  Latex-based thin-layer immunoaffinity chromatography for quantitation of protein analytes. , 1992, Analytical biochemistry.

[12]  S. V. Kulgod,et al.  Protein determination by ponceau S using digital color image analysis of protein spots on nitrocellulose membranes. , 1999, Analytical biochemistry.

[13]  T. Lybrand,et al.  Streptavidin-biotin binding energetics. , 1999, Biomolecular engineering.

[14]  G. Jerums,et al.  Detection of microalbuminuria in diabetic patients by urinary dipstick. , 1997, Diabetes research and clinical practice.

[15]  H. Parving,et al.  Prevention of diabetic renal disease with special reference to microalbuminuria , 1995, The Lancet.

[16]  S C Lou,et al.  One-step competitive immunochromatographic assay for semiquantitative determination of lipoprotein(a) in plasma. , 1993, Clinical chemistry.

[17]  M. Alderman,et al.  Assessment of a new dipstick test in screening for microalbuminuria in patients with hypertension. , 1998, American journal of hypertension.

[18]  J H Kim,et al.  Conductimetric membrane strip immunosensor with polyaniline-bound gold colloids as signal generator. , 2000, Biosensors & bioelectronics.

[19]  R. Magnotti,et al.  Methods to determine biotin-binding capacity of streptavidin-coated magnetic particles , 1999 .

[20]  K. M. Ward Renal function (microalbuminuria). , 1995, Analytical chemistry.