X-ray streak camera cathode development and timing accuracy of the 4ω ultraviolet fiducial system at the National Ignition Facility.

The convergent ablator experiments at the National Ignition Facility (NIF) are designed to measure the peak velocity and remaining ablator mass of an indirectly driven imploding capsule. Such a measurement can be performed using an x-ray source to backlight the capsule and an x-ray streak camera to record the capsule as it implodes. The ultimate goal of this experiment is to achieve an accuracy of 2% in the velocity measurement, which translates to a ±2 ps temporal accuracy over any 300 ps interval for the streak camera. In order to achieve this, a 4ω (263 nm) temporal fiducial system has been implemented for the x-ray streak camera at NIF. Aluminum, titanium, gold, and silver photocathode materials have been tested. Aluminum showed the highest relative quantum efficiency, with five times more peak signal counts per fiducial pulse when compared to Gold. The fiducial pulse data were analyzed to determine the centroiding statistical accuracy for incident laser pulse energies of 1 and 10 nJ, showing an accuracy of ±1.6 ps and ±0.7 ps, respectively.

[1]  Peter Torres,et al.  Reliable and repeatable characterization of optical streak cameras. , 2008, The Review of scientific instruments.

[2]  T. Durakiewicz,et al.  Work functions of elements expressed in terms of the Fermi energy and the density of free electrons , 1998 .

[3]  C. N. Berglund,et al.  Photoemission Studies of Copper and Silver: Experiment , 1964 .

[4]  Gilbert W. Collins,et al.  Streaked radiography measurements of convergent ablator performance (invited). , 2010, The Review of scientific instruments.

[5]  G. Hass,et al.  Optical Constants and Reflectance and Transmittance of Evaporated Aluminum in the Visible and Ultraviolet , 1961 .

[6]  D. S. Montgomery,et al.  Evaluating the accuracy of optical-streak-camera sweep rates using uncertain data , 1992 .

[7]  Gilbert W. Collins,et al.  Convergent ablator performance measurements , 2010 .

[8]  Martin Richardson,et al.  Optical fiducials for x‐ray streak cameras at LLE , 1986 .

[9]  N. Bobroff Position measurement with a resolution and noise‐limited instrument , 1986 .

[10]  Edward I. Moses,et al.  The National Ignition Facility: enabling fusion ignition for the 21st century , 2004 .

[11]  T. S. Perry,et al.  X‐ray radiographic measurements of radiation‐driven shock and interface motion in solid density material , 1993 .

[12]  Y. P. Opachich,et al.  A compact UV timing fiducial system for use with x-ray streak cameras at NIF , 2012, Other Conferences.

[13]  R. Cairns,et al.  Metal Photocathodes as Secondary Standards for Absolute Intensity Measurements in the Vacuum Ultraviolet , 1966 .

[14]  William E. Spicer,et al.  Modern theory and applications of photocathodes , 1993, Optics & Photonics.