Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy.

PURPOSE To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. METHODS In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from -60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position uncertainties, and marker displacement. RESULTS The sensor positions and the limit for the CWL condition were measured with excellent reproducibility (standard deviation ≤ 0.39 mm). The ghost marker detection algorithm had perfect detection accuracy for both the jig (1544 samples) and the anthropomorphic phantom (2045 samples). Pattern matching was successful for all samples from both phantoms as well as the 40 patient marker patterns. CONCLUSIONS The authors proposed a simple model to explain the origin of ghost markers and identified the CWL condition as the necessary condition for ghost marker occurrence. The retrospective ghost marker detection and elimination algorithms guarantee complete ghost marker elimination while providing the users with maximum flexibility in selecting the number of markers and their configuration to meet their clinic needs.

[1]  Ishwar K. Sethi,et al.  Feature Point Correspondence in the Presence of Occlusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[2]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[3]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[4]  John M Buatti,et al.  Optically guided patient positioning techniques. , 2005, Seminars in radiation oncology.

[5]  Zhengyou Zhang,et al.  Iterative point matching for registration of free-form curves and surfaces , 1994, International Journal of Computer Vision.

[6]  Geoffrey D Hugo,et al.  On-line target position localization in the presence of respiration: a comparison of two methods. , 2007, International journal of radiation oncology, biology, physics.

[7]  D. Verellen,et al.  Six dimensional analysis with daily stereoscopic x-ray imaging of intrafraction patient motion in head and neck treatments using five points fixation masks. , 2006, Medical physics.

[8]  S. Umeyama,et al.  Least-Squares Estimation of Transformation Parameters Between Two Point Patterns , 1991, IEEE Trans. Pattern Anal. Mach. Intell..

[9]  M. Schell,et al.  Stereotactic body radiation therapy: the report of AAPM Task Group 101. , 2010, Medical physics.

[10]  S L Meeks,et al.  A high-precision system for conformal intracranial radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[11]  F. Yin,et al.  The correlation evaluation of a tumor tracking system using multiple external markers. , 2006, Medical physics.

[12]  Jonathan G. Li,et al.  Prevention of gross setup errors in radiotherapy with an efficient automatic patient safety system , 2013, Journal of applied clinical medical physics.

[13]  Haibin Ling,et al.  Efficient Marker Matching Using Pair-Wise Constraints in Physical Therapy , 2010, ISVC.

[14]  Hui Yan,et al.  A phantom study on the positioning accuracy of the Novalis Body system. , 2003, Medical physics.

[15]  Patrick A Kupelian,et al.  Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[16]  Paul J. Besl,et al.  A Method for Registration of 3-D Shapes , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[17]  Mark J. Foley,et al.  Electron beam therapy at extended source‐to‐surface distance: a Monte Carlo investigation , 2008, Journal of applied clinical medical physics.

[18]  Hui Yan,et al.  Investigation of the location effect of external markers in respiratory‐gated radiotherapy , 2008, Journal of applied clinical medical physics.

[19]  M. Shah,et al.  Object tracking: A survey , 2006, CSUR.

[20]  Martin J Murphy,et al.  Fiducial-based targeting accuracy for external-beam radiotherapy. , 2002, Medical physics.

[21]  G Stroian,et al.  Elimination of ghost markers during dual sensor-based infrared tracking of multiple individual reflective markers. , 2004, Medical physics.

[22]  Timothy D. Solberg,et al.  Infrared patient positioning for stereotactic radiosurgery of extracranial tumors , 1999, Comput. Biol. Medicine.

[23]  Dirk Verellen,et al.  Initial clinical experience with infrared-reflecting skin markers in the positioning of patients treated by conformal radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[24]  Dirk Verellen,et al.  Clinical use of stereoscopic X-ray positioning of patients treated with conformal radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[25]  Fang-Fang Yin,et al.  Cone-beam CT localization of internal target volumes for stereotactic body radiotherapy of lung lesions. , 2007, International journal of radiation oncology, biology, physics.

[26]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[27]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[28]  Patrick A Kupelian,et al.  Optical tracking technology in stereotactic radiation therapy. , 2007, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[29]  L. Chin,et al.  Infrared-guided patient setup for lung cancer patients. , 2008, International journal of radiation oncology, biology, physics.

[30]  James Welsh,et al.  American Society for Therapeutic Radiology and Oncology and American College of Radiology practice guideline for the performance of stereotactic body radiation therapy. , 2004, International journal of radiation oncology, biology, physics.