Optical Coherence Tomography Angiography Using the Optovue Device.

Optovue AngioVue system technology for optical coherence tomography (OCT) angiography is based on the AngioVue Imaging System (Optovue, Inc., Freemont, CA), using split-spectrum amplitude-decorrelation angiography (SSADA) algorithm. This algorithm was developed to minimize scanning time. It detects motion in blood vessel lumen by measuring the variation in reflected OCT signal amplitude between consecutive cross-sectional scans. The novelty of SSADA lies in how the OCT signal is processed to enhance flow detection and reject axial bulk motion noise. Specifically, the algorithm splits the OCT image into different spectral bands, thus increasing the number of usable image frames. Each new frame has a lower axial resolution that is less susceptible to axial eye motion caused by blood pulsation. Optovue AngioVue system technology allows quantitative analysis. It provides numerical data about flow area and non-flow area. It can also generate a flow density map. These metrics may serve as biomarkers in diagnosis and for tracking disease progression or treatment response. Flow area: the software will calculate the drawn area and vessel area in mm(2). It allows for comparison of all measurements for a given participant. Non-flow area: the software shows the non-perfused areas by mouse click selection. Ischemic areas will be shown in yellow. These areas may be saved and matched with others in the study. Flow density tool is able to measure the percentage of vascular areas on en face angiograms. This analysis is based on an ETDRS grid centered on the macula as with the thickness map. This tool works both on inner and outer vascular plexus.

[1]  Martin Leahy,et al.  In vivo imaging of the microcirculation of the volar forearm using correlation mapping optical coherence tomography (cmOCT) , 2011, Biomedical optics express.

[2]  Maciej Wojtkowski,et al.  Scanning protocols dedicated to smart velocity ranging in spectral OCT. , 2009, Optics express.

[3]  Austin Roorda,et al.  Characterization of single-file flow through human retinal parafoveal capillaries using an adaptive optics scanning laser ophthalmoscope , 2011, Biomedical optics express.

[4]  Shuichi Makita,et al.  Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography. , 2011, Optics express.

[5]  Gangjun Liu,et al.  Optimization of the split-spectrum amplitude-decorrelation angiography algorithm on a spectral optical coherence tomography system. , 2015, Optics letters.

[6]  Bruce J. Tromberg,et al.  A comparison of Doppler optical coherence tomography methods , 2012, Biomedical optics express.

[7]  R. Leitgeb,et al.  Ultrahigh-speed non-invasive widefield angiography. , 2012, Journal of biomedical optics.

[8]  G. Lema OCT Angiography in Retinal and Macular Diseases , 2016 .

[9]  Simon S. Gao,et al.  Automated choroidal neovascularization detection algorithm for optical coherence tomography angiography. , 2015, Biomedical optics express.

[10]  James G. Fujimoto,et al.  Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization , 2014, Biomedical optics express.

[11]  Martin F. Kraus,et al.  Split-spectrum amplitude-decorrelation angiography with optical coherence tomography , 2012, Optics express.

[12]  Lingfeng Yu,et al.  Doppler variance imaging for three-dimensional retina and choroid angiography. , 2010, Journal of biomedical optics.

[13]  Martin F. Kraus,et al.  Optical coherence tomography angiography of optic disc perfusion in glaucoma. , 2014, Ophthalmology.

[14]  R. Leitgeb,et al.  Visualization of microvasculature by dual-beam phase-resolved Doppler optical coherence tomography. , 2011, Optics express.

[15]  David J. Wilson,et al.  Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye , 2015, Proceedings of the National Academy of Sciences.

[16]  Joseph A. Izatt,et al.  Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography , 2011, Biomedical optics express.

[17]  Reza Motaghiannezam,et al.  Logarithmic intensity and speckle-based motion contrast methods for human retinal vasculature visualization using swept source optical coherence tomography , 2012, Biomedical optics express.

[18]  Johannes F de Boer,et al.  Angiography of the retina and the choroid with phase-resolved OCT using interval-optimized backstitched B-scans. , 2012, Optics express.

[19]  Robert J Zawadzki,et al.  Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique. , 2009, Optics express.

[20]  James G. Fujimoto,et al.  Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns , 2012, Biomedical optics express.

[21]  C E Riva,et al.  Blue field entoptic phenomenon and blood velocity in the retinal capillaries. , 1980, Journal of the Optical Society of America.

[22]  Qienyuan Zhou,et al.  RETINAL VASCULAR PERFUSION DENSITY MAPPING USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IN NORMALS AND DIABETIC RETINOPATHY PATIENTS , 2015, Retina.

[23]  Adrian Mariampillai,et al.  Speckle variance detection of microvasculature using swept-source optical coherence tomography. , 2008, Optics letters.

[24]  Ruikang K. Wang,et al.  Three dimensional optical angiography. , 2007, Optics express.

[25]  David Huang,et al.  Blood flow velocity quantification using split-spectrum amplitude-decorrelation angiography with optical coherence tomography. , 2013, Biomedical optics express.

[26]  Martin F. Kraus,et al.  Quantitative optical coherence tomography angiography of choroidal neovascularization in age-related macular degeneration. , 2014, Ophthalmology.