Effects of the arterial radius and the center-line velocity on the conductivity and electrical impedance of pulsatile flow in the human common carotid artery
暂无分享,去创建一个
[1] D. N. Riahi. On Low Frequency Oscillatory Elastic Arterial Blood Flow with Stenosis , 2017 .
[2] Yong Zhu,et al. A theoretical computerized study for the electrical conductivity of arterial pulsatile blood flow by an elastic tube model. , 2016, Medical engineering & physics.
[3] S. Hegde,et al. Evaluation of Impedance Cardiography for Measurement of Stroke Volume in Congenital Heart Disease , 2016, Pediatric Cardiology.
[4] M. Yacoub,et al. Taking Cardiac Surgery to the People , 2014, Journal of Cardiovascular Translational Research.
[5] I. Henry,et al. Stroke volume obtained by electrical interrogation of the brachial artery: transbrachial electrical bioimpedance velocimetry , 2012, Physiological measurement.
[6] David A Steinman,et al. On the shape of the common carotid artery with implications for blood velocity profiles , 2011, Physiological measurement.
[7] G. Molenberghs,et al. Diurnal and position‐induced variability of impedance cardiography measurements in healthy subjects , 2010, Clinical physiology and functional imaging.
[8] B. Fernhall,et al. Racial differences in central blood pressure and vascular function in young men. , 2008, American journal of physiology. Heart and circulatory physiology.
[9] Brian J. Thomas,et al. The Electrical Impedance of Pulsatile Blood Flowing Through Rigid Tubes: A Theoretical Investigation , 2008, IEEE Transactions on Biomedical Engineering.
[10] R. Cobbold,et al. A viscoelastic model of arterial wall motion in pulsatile flow: implications for Doppler ultrasound clutter assessment , 2008, Physiological measurement.
[11] Rob M. Heethaar,et al. On the flow dependency of the electrical conductivity of blood , 2004, IEEE Transactions on Biomedical Engineering.
[12] Liu Zhao-rong,et al. An analysis model of pulsatile blood flow in arteries , 2003 .
[13] H. Kanai,et al. Orientation and Deformation of Erythrocytes in Flowing Blood , 1999, Annals of the New York Academy of Sciences.
[14] Jeffrey C. Lagarias,et al. Convergence Properties of the Nelder-Mead Simplex Method in Low Dimensions , 1998, SIAM J. Optim..
[15] H. G. Goovaerts,et al. The influence of pulsatile flow on blood resistivity in impedance cardiography , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[16] J. Tarbell,et al. Numerical analysis of flow in an elastic artery model. , 1992, Journal of biomechanical engineering.
[17] K. Visser. Electric conductivity of stationary and flowing human blood at low frequencies , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.
[18] John G. Webster,et al. The Contribution of Vessel Volume Change and Blood Resistivity Change to the Electrical Impedance Pulse , 1985, IEEE Transactions on Biomedical Engineering.
[19] Hiroshi Kanai,et al. Electrical Characteristics of Flowing Blood , 1979, IEEE Transactions on Biomedical Engineering.
[20] B. C. Penney,et al. Influence of erythrocyte velocity on impedance plethysmographic measurements , 1978, Medical and Biological Engineering and Computing.
[21] S. Ling,et al. A nonlinear analysis of pulsatile flow in arteries , 1972, Journal of Fluid Mechanics.
[22] R. Patterson,et al. Development and evaluation of an impedance cardiac output system. , 1966, Aerospace medicine.
[23] H. Fricke,et al. A Mathematical Treatment of the Electric Conductivity and Capacity of Disperse Systems I. The Electric Conductivity of a Suspension of Homogeneous Spheroids , 1924 .
[24] B. Gojanovic,et al. The Impending Dilemma of Electrocardiogram Screening in Athletic Children , 2015, Pediatric Cardiology.
[25] B. Thomas,et al. Comparison of a theoretical impedance model with experimental measurements of pulsatile blood flow , 2007 .
[26] Robert Patterson,et al. Contributions to the impedance cardiogram waveform , 2006, Annals of Biomedical Engineering.
[27] K. Visser,et al. Electric properties of flowing blood and impedance cardiography , 2006, Annals of Biomedical Engineering.
[28] Artur Polinski,et al. The contribution of blood-flow-induced conductivity changes to measured impedance , 2005, IEEE Transactions on Biomedical Engineering.
[29] J. Butcher. Numerical methods for ordinary differential equations , 2003 .
[30] Kiyomi Niki,et al. Relationship between the pressure and diameter of the carotid artery in humans , 2000, Heart and Vessels.
[31] K. Visser,et al. Investigation of the origin of the impedance cardiogram by means of exchange transfusion with stroma free haemoglobin solution in the dog. , 1990, Cardiovascular research.
[32] H. Apfel. Electrical Impedance of the Carotid Artery in Response to Various Types of Stress , 1990 .
[33] John A. Nelder,et al. A Simplex Method for Function Minimization , 1965, Comput. J..