Tuning magnetic nanostructures and flux concentrators for magnetoresistive sensors

The methods for the optimization of the magnetoresistive (MR) sensors are to reduce sources of noises, to increase the signal, and to understand the involved fundamental limitations. The high-performance MR sensors result from important magnetic tunnel junction (MTJ) properties, such as tunneling magnetoresistance ratio (TMR), coercivity (Hc), exchange coupling field (He), domain structures, and noise properties as well as the external magnetic flux concentrators. All these parameters are sensitively controlled by the magnetic nanostructures, which can be tuned by varying junction free layer nanostructures, geometry, and magnetic annealing process etc. In this paper, we discuss some of efforts that an optimized magnetic sensor with a sensitivity as high as 5,146 %/mT. This sensitivity is currently the highest among all MR-type sensors that have been reported. The estimated noise of our magnetoresistive sensor is 47 pT/Hz1/2 at 1 Hz. This magnetoresistance sensor dissipates only 100 μW of power while operating under an applied voltage of 1 V at room temperature.

[1]  Hideo Ohno,et al.  Tunnel magnetoresistance properties and film structures of double MgO barrier magnetic tunnel junctions , 2010 .

[2]  Stephen E. Russek,et al.  Magnetic noise in a low-power picotesla magnetoresistive sensor , 2009, 2009 IEEE Sensors.

[3]  Xiaolu Yin,et al.  Novel magnetic nanostructured multilayer for high sensitive magnetoresistive sensor , 2012, 2012 IEEE Sensors.

[4]  Albrecht Jander,et al.  Delta-sigma digital magnetometer utilizing bistable spin-dependent-tunneling magnetic sensors , 2006 .

[5]  Thibaut Devolder,et al.  Damping of CoxFe80−xB20 ultrathin films with perpendicular magnetic anisotropy , 2013 .

[6]  Hubert Blanchard Hall sensors with integrated magnetic flux concentrators , 1999 .

[7]  T. Sagara,et al.  Magnetoresistive Sensors , 1993, IEEE Translation Journal on Magnetics in Japan.

[8]  Philip W. T. Pong,et al.  Hysteresis loop collapse for linear response in magnetic-tunnel-junction sensors , 2009 .

[9]  Teya Topuria,et al.  Increased tunneling magnetoresistance using normally bcc CoFe alloy electrodes made amorphous without glass forming additives. , 2009, Physical review letters.

[10]  J. Paul,et al.  Wide range and tunable linear TMR sensor using two exchange pinned electrodes , 2009 .

[11]  Michael Pedersen,et al.  Progress toward a thousandfold reduction in 1∕f noise in magnetic sensors using an ac microelectromechanical system flux concentrator (invited) , 2006 .

[12]  Claude Fermon,et al.  Femtotesla Magnetic Field Measurement with Magnetoresistive Sensors , 2004, Science.

[13]  Rui Zhang,et al.  Dependence of noise in magnetic tunnel junction sensors on annealing field and temperature , 2008 .

[14]  Paulo P. Freitas,et al.  Low frequency picotesla field detection using hybrid MgO based tunnel sensors , 2007 .

[15]  Seiji Mitani,et al.  Influence of boron diffusion on the perpendicular magnetic anisotropy in Ta|CoFeB|MgO ultrathin films , 2015 .

[16]  Gregory P. Carman,et al.  Strain-induced modulation of perpendicular magnetic anisotropy in Ta/CoFeB/MgO structures investigated by ferromagnetic resonance , 2015 .

[17]  S. Lin,et al.  Differential scanning calorimetric determination of the thermal properties of amorphous Co60Fe20B20 and Co40Fe40B20 thin films , 2013 .

[18]  H. Ohno,et al.  Tunnel magnetoresistance of 604% at 300K by suppression of Ta diffusion in CoFeB∕MgO∕CoFeB pseudo-spin-valves annealed at high temperature , 2008 .

[19]  Gang Xiao,et al.  Two-dimensional field-sensing map and magnetic anisotropy dispersion in magnetic tunnel junction arrays , 2011 .

[20]  Kyung-Ho Shin,et al.  Magnetotransport properties of dual MgO barrier magnetic tunnel junctions consisting of CoFeB/FeNiSiB/CoFeB free layers , 2012 .

[21]  J. M. D. Coey,et al.  Field sensing in MgO double barrier magnetic tunnel junctions with a superparamagnetic Co50Fe50 free layer , 2012 .

[22]  J. M. Daughton,et al.  Exchange coupling between ferromagnetic and antiferromagnetic layers via Ru and application for a linear magnetic field sensor , 2006 .

[23]  Yasuo Ando,et al.  Fabrication of magnetic tunnel junctions with a bottom synthetic antiferro-coupled free layers for high sensitive magnetic field sensor devices , 2012 .

[24]  T. Miyazaki,et al.  Effect of Mg interlayer on perpendicular magnetic anisotropy of CoFeB films in MgO/Mg/CoFeB/Ta structure , 2012 .

[25]  M. Hehn,et al.  Very low 1/f noise at room temperature in fully epitaxial Fe/MgO/Fe magnetic tunnel junctions , 2007, 0803.3564.

[26]  Susana Cardoso,et al.  Low aspect ratio micron size tunnel magnetoresistance sensors with permanent magnet biasing integrated in the top lead , 2011 .

[27]  S. E. Russek,et al.  Picotesla Magnetic Sensors for Low-Frequency Applications , 2011, IEEE Transactions on Magnetics.

[28]  J. M. D. Coey,et al.  Yoke-shaped MgO-barrier magnetic tunnel junction sensors , 2012 .

[29]  R. P. Pant,et al.  Origin of 'in-plane' and 'out-of-plane' magnetic anisotropies in as-deposited and annealed CoFeB ferromagnetic thin films , 2015 .

[30]  Radivoje Popovic,et al.  Design of planar magnetic concentrators for high sensitivity Hall devices , 2002 .