This paper proposes for consideration as a nationally accepted consensus methodology a procedure for estimating the whole opaque wall R-value (whole-wall R-value), independent of system type and construction materials. The methodology is based on results from a three-dimensional heat conduction model capable of simulating heat flow in a variety of wood, metal, and masonry systems. These simulation results lead to a whole-wall R-value which include the thermal performance of not only the clear wall area, with insulation and structural elements, but also typical envelope interface details, including wall/wall (corners), wall/roof, wall/floor, wall/door, and wall/window connections. Results from these detailed computer simulations are combined into a single whole-wall R-value estimation and compared with simplified center-of-cavity and clear wall R-values.
[1]
Jeffrey E. Christian,et al.
Thermal evaluation of several configurations of insulation and structural materials for some metal stud walls
,
1995
.
[2]
Charles George Ramsey,et al.
Architectural Graphic Standards
,
1970
.
[3]
J. Kosny.
Wooden concrete: High thermal efficiency using waste wood
,
1994
.
[4]
Andre Omer Desjarlais,et al.
Influence of Architectural Details on the Overall Thermal Performance of Residential Wall Systems
,
1994
.
[5]
J. E. Christian,et al.
Laboratory measurements of the drying rates of low-slope roofing systems
,
1994
.
[6]
J. E. Christian,et al.
Reducing the uncertainties associated with using the ASHRAE zone method for R-value calculations of metal frame walls
,
1995
.