Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature.

BACKGROUND In the last decade several stereolithographic guided surgery systems were introduced to the market. In this context, scientific information regarding accuracy of implant placement and surgical and prosthodontical complications is highly relevant as it provides evidence to implement this surgical technique in a clinical setting. PURPOSE To review data on accuracy and surgical and prosthodontical complications using stereolithographical surgical guides for implant rehabilitation. MATERIAL AND METHODS PubMed database was searched using the following keywords: "three dimensional imaging,""image based surgery,""flapless guided surgery,""customized drill guides,""computer assisted surgery,""surgical template," and "stereolithography." Only papers in English were selected. Additional references found through reading of selected papers completed the list. RESULTS In total 31 papers were selected. Ten reported deviations between the preoperative implant planning and the postoperative implant locations. One in vitro study reported a mean apical deviation of 1.0 mm, three ex vivo studies a mean apical deviation ranging between 0.6 and 1.2 mm. In six in vivo studies an apical deviation between 0.95 and 4.5 mm was found. Six papers reported on complications mounting to 42% of the cases when stereolithographic guided surgery was combined with immediate loading. CONCLUSION Substantial deviations in three-dimensional directions are found between virtual planning and actually obtained implant position. This finding and additionally reported postsurgical complications leads to the conclusion that care should be taken whenever applying this technique on a routine basis.

[1]  M S Schwarz,et al.  CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery. Work in progress. , 1988, Radiology.

[2]  Tomas Albrektsson,et al.  Osseointegrated Oral implants , 1988 .

[3]  N Freiberg,et al.  Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants. , 1988, Journal of periodontology.

[4]  D. Bandy,et al.  CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery , 1989 .

[5]  Misch Ce Bone classification, training keys to implant success. , 1989, Dentistry today.

[6]  H Israelson,et al.  Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients. , 1992, The International journal of periodontics & restorative dentistry.

[7]  C H Basten,et al.  The use of radiopaque templates for predictable implant placement. , 1995, Quintessence international.

[8]  Basten Ch,et al.  The use of radiopaque templates for predictable implant placement. , 1995 .

[9]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[10]  K H Thunthy,et al.  Radiographic/surgical template incorporating metal telescopic tubes for accurate implant placement. , 1998, Practical periodontics and aesthetic dentistry : PPAD.

[11]  Guy Marchal,et al.  An image-guided planning system for endosseous oral implants , 1998, IEEE Transactions on Medical Imaging.

[12]  R Jacobs,et al.  Predictability of a three-dimensional planning system for oral implant surgery. , 1999, Dento maxillo facial radiology.

[13]  R Jacobs,et al.  Predictability of reformatted computed tomography for pre-operative planning of endosseous implants. , 1999, Dento maxillo facial radiology.

[14]  J L Coudert,et al.  Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques. , 2000, The Journal of oral implantology.

[15]  Scott D. Ganz Computer-Guided Surgery Utilizing a Computer-Milled Surgical Template , 2001 .

[16]  Paul Suetens,et al.  A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. , 2002, The International journal of oral & maxillofacial implants.

[17]  Paul Suetens,et al.  Image-Based Planning and Validation of C1-C2 Transarticular Screw Fixation Using Personalized Drill Guides , 1999, MICCAI.

[18]  Guillaume Champleboux,et al.  Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. , 2002, Clinical oral implants research.

[19]  Philippe B Tardieu,et al.  Computer-assisted implant placement. A case report: treatment of the mandible. , 2003, The International journal of oral & maxillofacial implants.

[20]  Reinhilde Jacobs,et al.  Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers. , 2003, Clinical oral implants research.

[21]  C Politis,et al.  Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. , 2003, International journal of oral and maxillofacial surgery.

[22]  Scott D Ganz Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants. , 2003, Practical procedures & aesthetic dentistry : PPAD.

[23]  David P Sarment,et al.  Stereolithographic surgical templates for placement of dental implants in complex cases. , 2003, The International journal of periodontics & restorative dentistry.

[24]  Predrag Sukovic,et al.  Accuracy of implant placement with a stereolithographic surgical guide. , 2003, The International journal of oral & maxillofacial implants.

[25]  S. Ganz Presurgical planning with CT-derived fabrication of surgical guides. , 2005, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[26]  Filip Schutyser,et al.  A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. , 2005, Clinical implant dentistry and related research.

[27]  Patricia R Cury,et al.  Clinical application of stereolithographic surgical guides for implant placement: preliminary results. , 2005, Journal of periodontology.

[28]  Steven D Sudbrink Computer-guided implant placement with immediate provisionalization: a case report. , 2005, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[29]  Scott D Ganz,et al.  Techniques for the use of CT imaging for the fabrication of surgical guides. , 2006, Atlas of the oral and maxillofacial surgery clinics of North America.

[30]  Dov M Almog,et al.  Cone beam computerized tomography-based dental imaging for implant planning and surgical guidance, Part 1: Single implant in the mandibular molar region. , 2006, The Journal of oral implantology.

[31]  Alan L Rosenfeld,et al.  Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 1: diagnostics, imaging, and collaborative accountability. , 2006, The International journal of periodontics & restorative dentistry.

[32]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[33]  Alan L Rosenfeld,et al.  Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: rapid-prototype medical modeling and stereolithographic drilling guides requiring bone exposure. , 2006, The International journal of periodontics & restorative dentistry.

[34]  Eric Blanchet,et al.  Effect of flapless surgery on pain experienced in implant placement using an image-guided system. , 2006, The International journal of oral & maxillofacial implants.

[35]  Herman K Kupeyan,et al.  Definitive CAD/CAM-guided prosthesis for immediate loading of bone-grafted maxilla: a case report. , 2006, Clinical implant dentistry and related research.

[36]  J E Zöller,et al.  Comparison of static and dynamic computer-assisted guidance methods in implantology. , 2006, International journal of computerized dentistry.

[37]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A clinical report. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[38]  Paulo Malo,et al.  The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months. , 2007, The Journal of prosthetic dentistry.

[39]  Daniel van Steenberghe,et al.  Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients. , 2007, The Journal of prosthetic dentistry.

[40]  R Jacobs,et al.  Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. , 2007, Journal of clinical periodontology.

[41]  Stephen F Balshi,et al.  A simple technique for immediate placement of definitive engaging custom abutments using computerized tomography and flapless guided surgery. , 2007, Quintessence international.

[42]  Werner Jaschke,et al.  Use of a surgical navigation system for CT-guided template production. , 2007, The International journal of oral & maxillofacial implants.

[43]  L. T. Yong,et al.  Complications of computer-aided-design/computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results. , 2008, Clinical implant dentistry and related research.

[44]  T. van de Velde,et al.  A model study on flapless implant placement by clinicians with a different experience level in implant surgery. , 2007, Clinical oral implants research.

[45]  M. Strauss,et al.  Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems: Accuracy of different computer-aided surgery systems , 2008 .

[46]  Abbas Azari,et al.  A novel stereolithographic surgical guide template for planning treatment involving a mandibular dental implant. , 2008, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[47]  Thomas J Balshi,et al.  Guided Implant Placement and Immediate Prosthesis Delivery Using Traditional Brånemark System Abutments: A Pilot Study of 23 Patients , 2008, Implant dentistry.

[48]  Ai Komiyama,et al.  Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery. , 2008, Clinical oral implants research.

[49]  A Azari,et al.  Using computer-guided implantology in flapless implant surgery of a maxilla: a clinical report. , 2008, Journal of oral rehabilitation.

[50]  Saad A Al-Harbi,et al.  Implant Placement Accuracy When Using Stereolithographic Template as a Surgical Guide: Preliminary Results , 2009, Implant dentistry.

[51]  C. Goodacre,et al.  Misfit of implant fixed complete denture following computer-guided surgery. , 2009, The International journal of oral & maxillofacial implants.

[52]  S. Rosenstiel,et al.  Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[53]  Hans Nilson,et al.  Digitally planned, immediately loaded dental implants with prefabricated prostheses in the reconstruction of edentulous maxillae: a 1-year prospective, multicenter study. , 2009, Clinical implant dentistry and related research.

[54]  G. Schiroli,et al.  Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. , 2009, The International journal of oral & maxillofacial implants.