Characterization of a photon counting EMCCD for space-based high contrast imaging spectroscopy of extrasolar planets

We present the progress of characterization of a low-noise, photon counting Electron Multiplying Charged Coupled Device (EMCCD) operating in optical wavelengths and demonstrate possible solutions to the problems of Clock-Induced Charge (CIC) and other trapped charge through sub-bandgap illumination. Such a detector will be vital to the feasibility of future space-based direct imaging and spectroscopy missions for exoplanet characterization, and is scheduled to y on-board the AFTA-WFIRST mission. The 512×512 EMCCD is an e2v detector housed and clocked by a Nüvü Cameras controller. Through a multiplication gain register, this detector produces as many as 5000 electrons for a single, incident-photon-induced photoelectron produced in the detector, enabling single photon counting operation with read noise and dark current orders of magnitude below that of standard CCDs. With the extremely high contrasts (Earth-to-Sun flux ratio is ~ 10-10) and extremely faint targets (an Earth analog would measure 28th - 30th magnitude or fainter), a photon-counting EMCCD is absolutely necessary to measure the signatures of habitability on an Earth-like exoplanet within the timescale of a mission's lifetime, and we discuss the concept of operations for an EMCCD making such measurements.

[1]  Keith Weller,et al.  Photon counting EMCCDs: new opportunities for high time resolution astrophysics , 2012, Other Conferences.

[2]  Olivier Daigle,et al.  The darkest EMCCD ever , 2010, Astronomical Telescopes + Instrumentation.

[3]  Sebastien Blais-Ouellette,et al.  Extreme Faint Flux Imaging with an EMCCD , 2009, 0911.4495.

[4]  René Doyon,et al.  Characterization results of EMCCDs for extreme low-light imaging , 2012, Other Conferences.

[5]  Richard G. Lyon,et al.  Detecting biomarkers in exoplanetary atmospheres with a Terrestrial Planet Finder , 2008, Astronomical Telescopes + Instrumentation.

[6]  John Trauger,et al.  PISCES: an integral field spectrograph to advance high contrast imaging technologies , 2013, Optics & Photonics - Optical Engineering + Applications.

[7]  Ralf Widenhorn,et al.  Residual images in charged-coupled device detectors , 2002 .

[8]  Fang Shi,et al.  Laboratory demonstrations of high-contrast imaging for space coronagraphy , 2007, SPIE Optical Engineering + Applications.

[9]  Derek Ives,et al.  ULTRASPEC: an electron multiplication CCD camera for very low light level high speed astronomical spectrometry , 2008, Astronomical Telescopes + Instrumentation.

[10]  Luis Marchen,et al.  The AFTA coronagraph instrument , 2013, Optics & Photonics - Optical Engineering + Applications.

[11]  Simon Tulloch Modeling the suitability of EMCCDs for spectroscopic applications , 2008, Astronomical Telescopes + Instrumentation.

[12]  Mark Clampin,et al.  Individual photon counting using e2v L3 CCDs for low background astronomical spectroscopy , 2006, SPIE Astronomical Telescopes + Instrumentation.

[13]  J. Hynecek,et al.  Excess noise and other important characteristics of low light level imaging using charge multiplying CCDs , 2003 .

[14]  D. Mawet,et al.  Overview of Technologies for Direct Optical Imaging of Exoplanets , 2009 .

[15]  Tom Brown,et al.  Science drivers and requirements for an Advanced Technology Large Aperture Space Telescope (ATLAST): implications for technology development and synergies with other future facilities , 2010, Astronomical Telescopes + Instrumentation.

[16]  B. Hadwen,et al.  The noise performance of electron multiplying charge-coupled devices , 2003 .

[17]  M. Schmid,et al.  Investigations on performance of Electron Multiplied CCD detectors (EMCCDs) after radiation for observation of low light star-like objects in scientific space missions , 2013, Remote Sensing.