High-resolution room-temperature sample scanning superconducting quantum interference device microscope configurable for geological and biomagnetic applications

We have developed a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with submillimeter resolution. The low-critical-temperature (Tc) niobium-based monolithic SQUID sensors are mounted on the tip of a sapphire and thermally anchored to the helium reservoir. A 25μm sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows us to adjust the sample-to-sensor spacing from the top of the Dewar. We achieved a sensor-to-sample spacing of 100μm, which could be maintained for periods of up to four weeks. Different SQUID sensor designs are necessary to achieve the best combination of spatial resolution and field sensitivity for a given source configuration. For imaging thin sections of geological samples, we used a custom-designed monolithic low-Tc niobium bare SQUID sensor, with an effective diameter of 80μm, and achieved a field sensitivity of 1.5...

[1]  Jenny R Holzer,et al.  High resolution magnetic images of planar wave fronts reveal bidomain properties of cardiac tissue. , 2004, Biophysical journal.

[2]  John P. Wikswo,et al.  SCANNING SQUID MICROSCOPY , 1999 .

[3]  L. Fong,et al.  Intracellular axial current in Chara corallina reflects the altered kinetics of ions in cytoplasm under the influence of light. , 2005, Biophysical journal.

[4]  John P. Wikswo,et al.  A superconducting quantum interference device magnetometer system for quantitative analysis and imaging of hidden corrosion activity in aircraft aluminum structures , 1999 .

[5]  E. A. Lima,et al.  High-resolution imaging of cardiac biomagnetic fields using a low-transition-temperature superconducting quantum interference device microscope , 2004 .

[6]  Bradley J. Roth,et al.  The effect of plunge electrodes during electrical stimulation of cardiac tissue , 2001, IEEE Transactions on Biomedical Engineering.

[7]  J. Kirtley SQUID microscopy for fundamental studies , 2002 .

[8]  J. Wikswo High-Resolution Magnetic Imaging: Cellular Action Currents and Other Applications , 1996 .

[9]  John P. Wikswo,et al.  Applications of SQUID Magnetometers to Biomagnetism and Nondestructive Evaluation , 2000 .

[10]  Joseph L. Kirschvink,et al.  Records of an ancient Martian magnetic field in ALH84001 , 2001 .

[11]  Harold Weinstock,et al.  Applications of superconductivity , 2000 .

[12]  Mark B. Ketchen,et al.  Planar coupling scheme for ultra low noise DC SQUIDs , 1981 .

[13]  John P. Wikswo,et al.  High resolution low-temperature superconductivity superconducting quantum interference device microscope for imaging magnetic fields of samples at room temperatures , 2002 .

[14]  J P Wikswo,et al.  A distributed quasi-static ionic current source in the 3-4 day old chicken embryo. , 1993, Physics in medicine and biology.

[15]  H. Weinstock A review of SQUID magnetometry applied to nondestructive evaluation , 1991 .

[16]  Harold Weinstock,et al.  SQUID sensors : fundamentals, fabrication, and applications , 1996 .

[17]  Y. Rudy,et al.  Electrocardiogram sources in a 2-dimensional anisotropic activation model , 2006, Medical and Biological Engineering and Computing.

[18]  J. E. Zimmerman,et al.  Sensitivity Enhancement of Superconducting Quantum Interference Devices through the Use of Fractional‐Turn Loops , 1971 .

[19]  J P Wikswo,et al.  A low temperature transfer of ALH84001 from Mars to Earth. , 2000, Science.

[20]  John Clarke,et al.  Tunnel junction dc SQUID: Fabrication, operation, and performance , 1976 .

[21]  R. Barr,et al.  Current flow patterns in two-dimensional anisotropic bisyncytia with normal and extreme conductivities. , 1984, Biophysical journal.

[22]  N. G. Sepulveda,et al.  Using a magnetometer to image a two‐dimensional current distribution , 1989 .

[23]  J. Wikswo,et al.  High resolution imaging of biomagnetic fields generated by action currents in cardiac tissue using a LTS-SQUID microscope , 2002 .

[24]  C. Carr,et al.  Integrated low-temperature superconductor SQUID gradiometers for nondestructive evaluation , 1997, IEEE Transactions on Applied Superconductivity.

[25]  John P. Wikswo,et al.  High-resolution high-speed synchronous epifluorescence imaging of cardiac activation , 1997 .

[26]  M. Radparvar,et al.  Monolithic low-transition-temperature superconducting magnetometers for high resolution imaging magnetic fields of room temperature samples , 2003 .

[27]  T. S. Lee,et al.  A new study of bacterial motion: superconducting quantum interference device microscopy of magnetotactic bacteria. , 1999, Biophysical journal.

[28]  Marc Kreutzbruck,et al.  A scanning superconducting quantum interference device microscope with high spatial resolution for room temperature samples , 2001 .

[29]  J. Clarke,et al.  High‐transition temperature superconducting quantum interference device microscope , 1996 .

[30]  L. A. Knauss,et al.  Scanning SQUID microscopy of integrated circuits , 2000 .

[31]  John Clarke,et al.  dc SQUID: Noise and optimization , 1977 .

[32]  HTS scanning SQUID microscopy of active circuits , 1999, IEEE Transactions on Applied Superconductivity.

[33]  John P. Wikswo,et al.  Magnetic microscopy promises a leap in sensitivity and resolution , 2001 .