Experimental Assessment of Winding Inter-turn Short-circuits in Six-Phase AC Permanent Magnet Synchronous Motors

Multiphase permanent magnet synchronous machines are receiving more and more interest in safety critical modern industry applications and in wind turbines, owing to their higher reliability, with respect to the classical three phase machines. In this context, diagnosing the stator windings status is necessary to guaranty the required high machine performance.In the present paper, the detection of stator inter-turn short-circuit, for six-phase AC permanent magnet machine, is investigated. The main contribution of the presented investigation is the assessment of stator inter-turn short-circuit detectability based on spectral analysis derived from the space vectors of the back-emfs accessible in the different $\alpha-\beta$ planes. The presented results are validated by means of two-dimensional finite element analysis, and then by experimental results, showing a very good agreement.

[1]  Manfred Schroedl,et al.  Advantages of PM-machines compared to induction machines in terms of efficiency and sensorless control in traction applications , 2011, IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society.

[2]  Ayman Mohamed Fawzi EL-Refaie,et al.  Fault-tolerant permanent magnet machines: a review , 2011 .

[3]  Sang Bin Lee,et al.  Detection and Classification of Stator Turn Faults and High Resistance Electrical Connections for Induction Machines , 2007, 2007 IEEE Industry Applications Annual Meeting.

[4]  Huang Qiu-Liang,et al.  Fault-Tolerant Control Strategy for Five-Phase PMSM With Third-Harmonic Current Injection , 2018, IEEE Access.

[5]  D. Casadei,et al.  Detection of Rotor Magnet Demagnetization in Asymmetrical Six-Phase Surface Mounted Permanent Magnet Synchronous Motor Drive , 2018, 2018 XIII International Conference on Electrical Machines (ICEM).

[6]  Slim Tnani,et al.  Efficient Simplified Physical Faulty Model of a Permanent Magnet Synchronous Generator Dedicated to the Stator Fault Diagnosis Part I: Faulty Model Conception , 2017, IEEE Transactions on Industry Applications.

[7]  Yihua Hu,et al.  Remedial Strategies of T-NPC Three-Level Asymmetric Six-Phase PMSM Drives Based on SVM-DTC , 2017, IEEE Transactions on Industrial Electronics.

[8]  R. M. Tallam,et al.  A survey of methods for detection of stator related faults in induction machines , 2003, 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003..

[9]  Emil Levi,et al.  Advances in Converter Control and Innovative Exploitation of Additional Degrees of Freedom for Multiphase Machines , 2016, IEEE Transactions on Industrial Electronics.

[10]  Yangzhong Zhou,et al.  Predictive DTC Strategy With Fault-Tolerant Function for Six-Phase and Three-Phase PMSM Series-Connected Drive System , 2018, IEEE Transactions on Industrial Electronics.

[11]  Domenico Casadei,et al.  Assessment of current and voltage signature analysis for the diagnosis of rotor magnet demagnetization in five-phase AC permanent magnet generator drives , 2019, Math. Comput. Simul..

[12]  Ming Cheng,et al.  Fault-Tolerant Control of Dual Three-Phase Permanent-Magnet Synchronous Machine Drives Under Open-Phase Faults , 2017, IEEE Transactions on Power Electronics.

[13]  Y. Gritli,et al.  Detection of magnet demagnetization and high-resistance connections in five-phase surface-mounted permanent magnet generators , 2015, 2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED).