Orthogonal Injection Ion Funnel Interface Providing Enhanced Performance for Selected Reaction Monitoring-Triple Quadrupole Mass Spectrometry.

The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher-pressure regions (e.g., ion source interfaces) of mass spectrometers, thus providing increased sensitivity. An "off-axis" ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to-charge ratios. In this study, a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadrupole mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at a pressure of 9-10 Torr. Key factors for the HPIF performance characterized included the effects of RF amplitude, the DC gradient, and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. The sensitivity enhancement in liquid chromatography selected reaction monitoring (LC-SRM) analyses of low-abundance peptides spiked into a highly complex mixture was also compared with that obtained using both a commercial S-lens interface and an in-line dual-ion funnel interface.

[1]  Ioan Marginean,et al.  Achieving 50% ionization efficiency in subambient pressure ionization with nanoelectrospray. , 2010, Analytical chemistry.

[2]  R. Smith,et al.  A multicapillary inlet jet disruption electrodynamic ion funnel interface for improved sensitivity using atmospheric pressure ion sources. , 2001, Analytical chemistry.

[3]  L. B. Jones,et al.  A new type of GC–MS with advanced capabilities , 2006 .

[4]  A. Bruins Mass spectrometry with ion sources operating at atmospheric pressure , 1991 .

[5]  Ronald J Moore,et al.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry. , 2006, Analytical chemistry.

[6]  Yehia M. Ibrahim,et al.  Ion funnel trap interface for orthogonal time-of-flight mass spectrometry. , 2007, Analytical chemistry.

[7]  Brendan MacLean,et al.  Bioinformatics Applications Note Gene Expression Skyline: an Open Source Document Editor for Creating and Analyzing Targeted Proteomics Experiments , 2022 .

[8]  Yehia M. Ibrahim,et al.  Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface , 2006, Journal of the American Society for Mass Spectrometry.

[9]  Ryan T Kelly,et al.  The ion funnel: theory, implementations, and applications. , 2009, Mass spectrometry reviews.

[10]  Kim,et al.  Improved ion transmission from atmospheric pressure to high vacuum using a multicapillary inlet and electrodynamic ion funnel interface , 2000, Analytical chemistry.

[11]  Yehia M. Ibrahim,et al.  Pulsed multiple reaction monitoring approach to enhancing sensitivity of a tandem quadrupole mass spectrometer. , 2011, Analytical chemistry.

[12]  A. Tolmachev,et al.  A new technique for decomposition of selected ions in molecule ion reactor coupled with ortho-time-of-flight mass spectrometry. , 1997, Rapid communications in mass spectrometry : RCM.

[13]  C. Ng State-Selected and State-to-State Ion−Molecule Reaction Dynamics , 2002 .

[14]  P. Kebarle,et al.  FROM IONS IN SOLUTION TO IONS IN THE GAS PHASE , 1993 .

[15]  Richard D. Smith,et al.  Independent control of ion transmission in a jet disrupter dual-channel ion funnel electrospray ionization MS interface. , 2002, Analytical chemistry.

[16]  Richard D. Smith,et al.  On the Ionization and Ion Transmission Efficiencies of Different ESI-MS Interfaces , 2014, Journal of The American Society for Mass Spectrometry.

[17]  Scott A. McLuckey,et al.  The American Society for Mass Spectrometry , 1996 .