Integrated polymerase chain reaction chips utilizing digital microfluidics

This study reports an integrated microfluidic chip for polymerase chain reaction (PCR) applications utilizing digital microfluidic chip (DMC) technology. Several crucial procedures including sample transportation, mixing, and DNA amplification were performed on the integrated chip using electro-wetting-on-dielectric (EWOD) effect. An innovative concept of hydrophobic/hydrophilic structure has been successfully demonstrated to integrate the DMC chip with the on-chip PCR device. Sample droplets were generated, transported and mixed by the EWOD-actuation. Then the mixture droplets were transported to a PCR chamber by utilizing the hydrophilic/hydrophobic interface to generate required surface tension gradient. A micro temperature sensor and two micro heaters inside the PCR chamber along with a controller were used to form a micro temperature control module, which could perform precise PCR thermal cycling for DNA amplification. In order to demonstrate the performance of the integrated DMC/PCR chips, a detection gene for Dengue II virus was successfully amplified and detected. The new integrated DMC/PCR chips only required an operation voltage of 12VRMS at a frequency of 3 KHz for digital microfluidic actuation and 9VDC for thermal cycling. When compared to its large-scale counterparts for DNA amplification, the developed system consumed less sample and reagent and could reduce the detection time. The developed chips successfully demonstrated the feasibility of Lab-On-a-Chip (LOC) by utilizing EWOD-based digital microfluidics.

[1]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[2]  Qintao Zhang,et al.  Temperature analysis of continuous-flow micro-PCR based on FEA , 2002 .

[3]  Stephen Quake,et al.  A nanoliter rotary device for polymerase chain reaction , 2002, Electrophoresis.

[4]  Gwo-Bin Lee,et al.  Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. , 2005, Biosensors & bioelectronics.

[5]  Gwo-Bin Lee,et al.  Integrated microfluidic systems for cell lysis, mixing/pumping and DNA amplification , 2005 .

[6]  Phil Paik,et al.  Electrowetting-based droplet mixers for microfluidic systems. , 2003, Lab on a chip.

[7]  Alan Mathewson,et al.  Application of magnetohydrodynamic actuation to continuous flow chemistry. , 2002, Lab on a chip.

[8]  Ichimura,et al.  Light-driven motion of liquids on a photoresponsive surface , 2000, Science.

[9]  L J Kricka,et al.  Chip PCR. II. Investigation of different PCR amplification systems in microbabricated silicon-glass chips. , 1996, Nucleic acids research.

[10]  C. Kim,et al.  Electrowetting and electrowetting-on-dielectric for microscale liquid handling , 2002 .

[11]  Mwj Menno Prins,et al.  Fluid control in multichannel structures by electrocapillary pressure. , 2001, Science.

[12]  H. John Crabtree,et al.  Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection. , 2003, Analytical chemistry.

[13]  L J Kricka,et al.  Chip PCR. I. Surface passivation of microfabricated silicon-glass chips for PCR. , 1996, Nucleic acids research.

[14]  Hye Jung Cho,et al.  Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip , 2002 .

[15]  Sigurd Wagner,et al.  Thermocapillary actuation of droplets on chemically patterned surfaces by programmable microheater arrays , 2003 .

[16]  A. Wixforth,et al.  Planar chip device for PCR and hybridization with surface acoustic wave pump. , 2005, Lab on a chip.

[17]  Rohit Rosario,et al.  Lotus Effect Amplifies Light-Induced Contact Angle Switching , 2004 .

[18]  R. Mathies,et al.  Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system , 2000 .

[19]  M. A. Northrup,et al.  A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers. , 1998, Analytical chemistry.

[20]  Christopher R. Lowe,et al.  Silicon microchambers for DNA amplification , 1998 .

[21]  S. Cho,et al.  Low voltage electrowetting-on-dielectric , 2002 .

[22]  R. Fair,et al.  Electrowetting-based actuation of droplets for integrated microfluidics. , 2002, Lab on a chip.

[23]  John Ralston,et al.  Influence of the Electrical Double Layer in Electrowetting , 2003 .

[24]  Gwo-Bin Lee,et al.  Miniature RT–PCR system for diagnosis of RNA-based viruses , 2005, Nucleic acids research.

[25]  P. Gascoyne,et al.  Droplet-based chemistry on a programmable micro-chip. , 2004, Lab on a chip.

[26]  M. A. Northrup,et al.  Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device. , 1996, Analytical chemistry.

[27]  S. Cho,et al.  Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits , 2003 .

[28]  R. Fair,et al.  Electrowetting-based actuation of liquid droplets for microfluidic applications , 2000 .

[29]  J. Schäfer,et al.  The polymerase chain reaction. Herausgegeben von K. B. Mullis, F. Ferre und R. A. Gibbs. 458 Seiten, 112 Abbildungen, zahlr. Tabellen, Birkhäuser, Boston, Basel, Berlin 1994. Preis: 169, — DM , 1995 .

[30]  R. Gibbs,et al.  The Polymerase Chain Reaction , 1994, Birkhäuser Boston.

[31]  J. Coninck,et al.  Dynamics of Spontaneous Spreading under Electrowetting Conditions , 2000 .

[32]  Ulrich Dillner,et al.  Chip elements for fast thermocycling , 1997 .

[33]  T. Higuchi,et al.  Chemical reactions in microdroplets by electrostatic manipulation of droplets in liquid media. , 2002, Lab on a chip.

[34]  Gwo-Bin Lee,et al.  MEMS-based Temperature Control Systems for DNA Amplification , 2002 .

[35]  A Manz,et al.  Chemical amplification: continuous-flow PCR on a chip. , 1998, Science.

[36]  D. Cui,et al.  Design and Microfabrication of Biochemical Reaction Chip , 2002 .

[37]  J. Köhler,et al.  Flow-through polymerase chain reactions in chip thermocyclers. , 2001, Journal of biotechnology.

[38]  L. G. J. Fokkink,et al.  Fast Electrically Switchable Capillary Effects , 1998 .

[39]  Hiroaki Misawa,et al.  A heater-integrated transparent microchannel chip for continuous-flow PCR , 2002 .

[40]  H. Verheijen,et al.  REVERSIBLE ELECTROWETTING AND TRAPPING OF CHARGE : MODEL AND EXPERIMENTS , 1999, cond-mat/9908328.