Difference between clinic and daytime blood pressure is not a measure of the white coat effect.

The purpose of the present study was to evaluate whether the difference between blood pressure measured in the clinic or physician's office and the average daytime blood pressure accurately reflects the blood pressure response of the patient to the physician ("white coat effect" or "white coat hypertension"). We studied 28 hypertensive outpatients (mean age, 41.8+/-11.2 years; age range, 21 to 64 years) of 35 consecutive patients attending our hypertension clinic, in whom (1) continuous noninvasive finger blood pressure was recorded before and during the visit, (2) blood pressure was measured according to the Riva-Rocci-Korotkoff method (mercury sphygmomanometer) with the patient in the supine position, and (3) daytime ambulatory blood pressure was monitored with a SpaceLabs 90207 device. The peak blood pressure increase recorded directly during the visit was compared with the difference between clinic and daytime average ambulatory blood pressures. Compared with previsit values, peak increases in finger systolic and diastolic blood pressures during the visit to the clinic were 38.2+/-3.1 and 20.7+/-1.6 mm Hg, respectively (mean+/-SEM, P<.01 for both). Daytime average systolic and diastolic blood pressures were 135.5+/-2.5 and 89.2+/-1.9 mm Hg, with both lower than the corresponding clinic blood pressure values (146.6+/-3.6 and 94.9+/-2.2 mm Hg, P<.01). These differences, however, were <30% of the peak finger blood pressure increases during the physician's visit, to which these increases showed no relation. Although the visit to the physician's office was associated with tachycardia (9.0+/-1.6 bpm, P<.01), there was no difference between clinic and daytime average heart rates. These data indicate that the clinic-daytime average blood pressure difference does not reflect the alerting reaction and the pressure response elicited by the physician's visit and thus is not a reliable measure of the white coat effect.

[1]  G. Mancia,et al.  White-coat hypertension: misnomers, misconceptions and misunderstandings. What should we do next? , 1996, Journal of hypertension.

[2]  G. Parati,et al.  Difference between office and ambulatory blood pressure and response to antihypertensive treatment , 1996, Journal of hypertension.

[3]  G. Parati,et al.  Experience with continuous non-invasive finger blood pressure monitoring: A new research tool. , 1995 .

[4]  I. Kuwajima,et al.  Is white coat hypertension innocent? Structure and function of the heart in the elderly. , 1993, Hypertension.

[5]  P. Gosse,et al.  'White coat' hypertension. No harm for the heart. , 1993, Hypertension.

[6]  G Parati,et al.  Ambulatory blood pressure monitoring use in hypertension research and clinical practice. , 1993, Hypertension.

[7]  G. Parati,et al.  Limited reproducibility of hourly blood pressure values obtained by ambulatory blood pressure monitoring: implications for studies on antihypertensive drugs , 1992, Journal of hypertension.

[8]  B. Moon Research and clinical practice. , 1992, Neonatal network : NN.

[9]  R. Reeves,et al.  White coat phenomenon in patients receiving antihypertensive therapy. , 1991, American journal of hypertension.

[10]  G. Parati,et al.  Reproducibility of non-invasive and intra-arterial blood pressure monitoring: implications for studies on antihypertensive treatment. , 1991, Journal of hypertension.

[11]  G. Mancia,et al.  Ambulatory blood pressure monitoring: research and clinical applications. , 1990, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[12]  N. Schork,et al.  “White Coat” Versus “Sustained” Borderline Hypertension in Tecumseh, Michigan , 1990, Hypertension.

[13]  M A Schalekamp,et al.  Comparison of Finapres non-invasive beat-to-beat finger blood pressure with intrabrachial artery pressure during and after bicycle ergometry. , 1989, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[14]  G. Parati,et al.  Comparison of Finger and Intra‐arterial Blood Pressure Monitoring at Rest and During Laboratory Testing , 1989, Hypertension.

[15]  A. Coats,et al.  Value of ambulatory blood pressure monitoring in clinical pharmacology. , 1989, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[16]  G. Parati,et al.  Comparison of the cardiovascular effects of different laboratory stressors and their relationship with blood pressure variability. , 1988, Journal of hypertension.

[17]  J. Karemaker,et al.  Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre. , 1988, Cardiovascular research.

[18]  J. Laragh,et al.  How common is white coat hypertension? , 1988, JAMA.

[19]  G Parati,et al.  Relationship of 24-hour blood pressure mean and variability to severity of target-organ damage in hypertension. , 1987, Journal of hypertension.

[20]  G Parati,et al.  Alerting reaction and rise in blood pressure during measurement by physician and nurse. , 1987, Hypertension.

[21]  Giuseppe Mancia,et al.  EFFECTS OF BLOOD-PRESSURE MEASUREMENT BY THE DOCTOR ON PATIENT'S BLOOD PRESSURE AND HEART RATE , 1983, The Lancet.

[22]  A Pedotti,et al.  Blood Pressure and Heart Rate Variabilities in Normotensive and Hypertensive Human Beings , 1983, Circulation research.

[23]  M. Sokolow,et al.  Relationship Between Level of Blood Pressure Measured Casually and by Portable Recorders and Severity of Complications in Essential Hypertension , 1966, Circulation.