Signal Quality Indices for Ambulatory Electrocardiograms Used in Myocardial Ischemia Monitoring

Ambulatory electrocardiograms (ECG) can be used to monitor patients for myocardial ischemia. Low ECG signal quality, due to contaminants such as motion artifact, can lead to an increase in false alarms leading to alarm fatigue. The false alarms can be reduced by processing only ECGs of ade-quate quality, quantified by a signal quality index (SQI); con-taminated ECG may be discarded. Four SQIs based on an esti-mate of the signal-to-noise ratio (SNR) were examined, where the mean, median, 25th percentile and minimum SNR were con-sidered. The SQIs were validated by contaminating 30 second segments of the record ‘s20031’ from the Physionet’s Long-Term ST Database with 30 second segments of the record ‘em’ from the Physionet’s Noise Stress Test Database. The SQIs of each segment were compared to the calibrated SNR of the segment. It was found that a strong correlation (Pearson correla-tion coefficient > 0.85) was exhibited between the SQIs and the calibrated SNR for each segment with SQI based on 25th percentile exhibiting highest correlation.

[1]  Harlan M Krumholz,et al.  2013 ACCF/AHA guideline for the management of ST-elevation myocardial infarction: executive summary: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. , 2013, Circulation.

[2]  M. Simoons,et al.  Gradual Changes of ECG Waveform During and After Exercise in Normal Subjects , 1975, Circulation.

[3]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[4]  A. Taddei,et al.  Long-term ST database: A reference for the development and evaluation of automated ischaemia detectors and for the study of the dynamics of myocardial ischaemia , 2003, Medical and Biological Engineering and Computing.

[5]  Gordon H. Guyatt,et al.  Perioperative cardiac events in patients undergoing noncardiac surgery: a review of the magnitude of the problem, the pathophysiology of the events and methods to estimate and communicate risk , 2005, Canadian Medical Association Journal.

[6]  E. W. Hancock,et al.  Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Card , 2007, Journal of the American College of Cardiology.

[7]  Fabio Badilini,et al.  Beat-to-beat quantification and analysis of ST displacement from Holter ECGs: a new approach to ischemia detection , 1992, Proceedings Computers in Cardiology.