Comparison of metal artifact in digital tomosynthesis and computed tomography for evaluation of phantoms

We compared metal artifact in X-ray digital tomosynthesis (DT) and modern computed tomography (CT) reconstruction to improve the image quality. We compared the images of a prosthetic phantom (titanium) and a contrast-detail phantom obtained by DT using conventional filtered backprojection (FBP), metal artifact reduction (MAR) processing, and simultaneous iterative reconstruction technique (SIRT) methods and those obtained by CT using conventional FBP and adaptive statistical iterative reconstruction methods. The effectiveness of each method for enhancing the visibility of a prosthetic phantom was quantified in terms of the intensity profile and root mean square error, and the removal of ghosting artifacts was quantified in terms of the artifact spread function (ASF). In addition, low contrast resolution was evaluated in terms of the contrast-to- noise ratio. Image error was smaller in the MAR DT images in the near in-focus-plane, and the intensity profiles revealed the beam hardening effect. Streak artifacts were reduced in the SIRT DT and adaptive statistical iterative reconstruction CT images. The ASF performances of the algorithms were ranked in descending order: 1) MAR DT; 2) CT (adaptive statistical iterative reconstruction, and conventional FBP); 3) SIRT DT; and 4) conventional FBP DT. The low contrast resolution was higher in the CT images than in the DT images. In conclusion, a review of the results revealed that the metal artifact reduction was highest for tomosynthesis with MAR processing, and the low contrast resolution performance was highest for CT.

[1]  S Sone,et al.  Development of a high-resolution digital tomosynthesis system and its clinical application. , 1991, Radiographics : a review publication of the Radiological Society of North America, Inc.

[2]  B. G. Ziedses des Plantes,et al.  EINE NEUE METHODE ZUR DIFFERENZIERUNG IN DER RÖNTGENOGRAPHIE (PLANIGRAPHIE) , 1932 .

[3]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[4]  M. Tapiovaara,et al.  PCXMC. A PC-based Monte Carlo program for calculating patient doses in medical x-ray examinations , 1997 .

[5]  E. Miller,et al.  An infinite number of laminagrams from a finite number of radiographs. , 1971, Radiology.

[6]  K. Oguchi,et al.  Image processing in the digital tomosynthesis for pulmonary imaging , 2004, European Radiology.

[7]  Alvin C. Silva,et al.  Iterative Reconstruction Technique for Reducing Body Radiation Dose at Ct: Feasibility Study Hara Et Al. Ct Iterative Reconstruction Technique Gastrointestinal Imaging Original Research , 2022 .

[8]  L. Desbat,et al.  An adapted fan volume sampling scheme for 3D algebraic reconstruction in linear tomosynthesis , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[9]  M W Vannier,et al.  Fast iterative algorithm for metal artifact reduction in X-ray CT. , 2000, Academic radiology.

[10]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[11]  Haruhiko Machida,et al.  Optimizing parameters for flat-panel detector digital tomosynthesis. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[12]  Cyrill Burger,et al.  Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner , 2003, European Radiology.

[13]  Kenneth A Buckwalter,et al.  CT of the hip prosthesis: appearance of components, fixation, and complications. , 2012, Radiographics : a review publication of the Radiological Society of North America, Inc.

[14]  Jacob Geleijns,et al.  Metal artifact reduction for CT: development, implementation, and clinical comparison of a generic and a scanner-specific technique. , 2012, Medical physics.

[15]  Wang,et al.  Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region Reconstruction , 1999, Microscopy and Microanalysis.

[16]  Tsutomu Gomi,et al.  Clinical Potential of Digital Linear Tomosynthesis Imaging of Total Joint Arthroplasty , 2008, Journal of Digital Imaging.

[17]  Tokuo Umeda,et al.  Evaluation of the X-ray digital linear tomosynthesis reconstruction processing method for metal artifact reduction , 2009, Comput. Medical Imaging Graph..

[18]  Noriyuki Tomiyama,et al.  Adaptive statistical iterative reconstruction technique for pulmonary CT: image quality of the cadaveric lung on standard- and reduced-dose CT. , 2010, Academic radiology.

[19]  Richard L. Webber,et al.  Restoration of Digital Multiplane Tomosynthesis by a Constrained Iteration Method , 1984, IEEE Transactions on Medical Imaging.

[20]  Patrick Dupont,et al.  Reduction of metal streak artifacts in X-ray computed tomography using a transmission maximum a posteriori algorithm , 1999 .

[21]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[22]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[23]  W. Capello,et al.  Multichannel CT Imaging of Orthopedic Hardware and Implants , 2006, Seminars in musculoskeletal radiology.

[24]  Bruce D. Smith Image Reconstruction from Cone-Beam Projections: Necessary and Sufficient Conditions and Reconstruction Methods , 1985, IEEE Transactions on Medical Imaging.

[25]  D. G. Grant Tomosynthesis: a three-dimensional radiographic imaging technique. , 1972, IEEE transactions on bio-medical engineering.

[26]  B. G. Ziedses des Plantes,et al.  Eine Neue Methode Zur Differenzierung in der Rontgenographie (Planigraphies) , 1932 .

[27]  S. Zhao,et al.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses , 2000, IEEE Transactions on Medical Imaging.

[28]  E. Samei,et al.  Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience. , 2010, Radiology.

[29]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[30]  W. Kalender,et al.  A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images , 2004, European Radiology.

[31]  P. Bleuet,et al.  An adapted fan volume sampling scheme for 3-D algebraic reconstruction in linear tomosynthesis , 2001 .

[32]  Erhard Klotz,et al.  Digital flashing tomosynthesis: a promising technique for angiocardiographic screening , 1993, IEEE Trans. Medical Imaging.

[33]  R A Kruger,et al.  Dynamic tomographic digital subtraction angiography using temporal filtration. , 1983, Radiology.

[34]  E. Previc Biochemical determination of bacterial morphology and the geometry of cell division. , 1970, Journal of theoretical biology.

[35]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[36]  Yong-Min Huh,et al.  Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[37]  J Duryea,et al.  Digital tomosynthesis of hand joints for arthritis assessment. , 2003, Medical physics.

[38]  M. Tapiovaara,et al.  PCXMC, A Monte Carlo program for calculating patient doses in medical x-ray examinations (2nd Ed , 2008 .

[39]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[40]  Kenneth A Buckwalter,et al.  Technical considerations: CT and MR imaging in the postoperative orthopedic patient. , 2002, Seminars in musculoskeletal radiology.