Measurement accuracy in control of segmented-mirror telescopes.

Design concepts for future large optical telescopes have highly segmented primary mirrors, with the out-of-plane degrees of freedom actively controlled. We estimate the contribution to errors in controlling the primary mirror that results from sensor noise and, in particular, compare mechanical measurements of relative segment motion with optical wave-front information. Data from the Keck telescopes are used to obtain realistic estimates of the achievable noise due to mechanical sensors. On the basis of these estimates, mechanical sensors will be more accurate than wave-front information for any of the telescope design concepts currently under consideration, and therefore supplemental wave-front sensors are not required for real-time figure control. Furthermore, control system errors due to sensor noise will not significantly degrade either seeing-limited or diffraction-limited observations.

[1]  Gary Chanan,et al.  Control and alignment of segmented-mirror telescopes: matrices, modes, and error propagation. , 2004, Applied optics.

[2]  George Gabor,et al.  W. M. Keck Telescope segmented primary mirror active control system , 1990, Astronomical Telescopes and Instrumentation.

[3]  Gary Chanan,et al.  ACTIVE CONTROL ISSUES FOR THE CALIFORNIA EXTREMELY LARGE TELESCOPE , 2001 .

[4]  L. Noethe,et al.  Closed-Loop Active Optics: Its Advantages And Limitations For Correction Of Wind-Buffet Deformations Of Large Flexible Mirrors , 1989, Defense, Security, and Sensing.

[5]  Gary Chanan,et al.  Control of the California Extremely Large Telescope primary mirror , 2003, SPIE Astronomical Telescopes + Instrumentation.

[6]  Douglas G. MacMartin Control challenges for extremely large telescopes , 2003, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[7]  S. Padin,et al.  Wind-induced deformations in a segmented mirror. , 2002, Applied optics.

[8]  Warren Davison,et al.  Model of image degradation due to wind buffeting on an extremely large telescope. , 2004, Applied optics.

[9]  Terry S. Mast,et al.  Segmented mirror control system hardware for CELT , 2000, Astronomical Telescopes and Instrumentation.

[10]  Jesús Flores-Mijangos,et al.  Far-infrared laser measurement of the refractive index of polypropylene. , 2003, Applied optics.

[11]  Mette Owner-Petersen,et al.  The Euro50 Extremely Large Telescope , 2003, SPIE Astronomical Telescopes + Instrumentation.

[12]  Philippe Dierickx,et al.  OWL optical design, active optics, and error budget , 2000, Astronomical Telescopes and Instrumentation.

[13]  Brooke Gregory,et al.  Giant segmented mirror telescope: a point design based on science drivers , 2003, SPIE Astronomical Telescopes + Instrumentation.

[14]  Terry S. Mast,et al.  Performance of the W.M. Keck telescope active mirror control system , 1994, Astronomical Telescopes and Instrumentation.