Experimental investigation of header configuration improvement in plate–fin heat exchanger

Abstract Flow characteristics in the header of a plate–fin heat exchanger have been investigated by means of Particle Image Velocimetry (PIV). A series of velocity vector and streamline graphs of different cross-sections are obtained in the experiment. The experimental results indicate that performance of fluid maldistribution in a conventional header is very serious, while the improved header configuration with a punched baffle can effectively enhance the uniformity of flow distribution. The flow maldistribution parameter and the ratio of the maximum velocity to the minimum in a plate–fin heat exchanger decreases by installing the punched baffle. Further heat exchange experiments indicate that the temperature is distributed more uniformly in the improved heat exchanger core and the heat exchanger effectiveness can be effectively enhanced. The conclusion of this paper is of great significance in the optimum design of plate–fin heat exchanger.

[1]  Kankanhalli N. Seetharamu,et al.  The combined effects of wall longitudinal heat conduction, inlet fluid flow nonuniformity and temperature nonuniformity in compact tube–fin heat exchangers: a finite element method , 1999 .

[2]  Sylvain Lalot,et al.  Flow maldistribution in heat exchangers , 1999 .

[3]  J. P. Chiou,et al.  The Combined Effects of Maldistributions of the Inlet Air Temperature and the Induced Flow Nonuniformity on the Performances of Radiator, Heater, and Oil Cooler , 1985 .

[4]  Yanzhong Li,et al.  CFD simulation on inlet configuration of plate-fin heat exchangers , 2003 .

[5]  M. Funes-Gallanzi High accuracy measurement of unsteady flows using digital particle image velocimetry , 1998 .

[6]  Wilfried Roetzel,et al.  Consideration of maldistribution in heat exchangers using the hyperbolic dispersion model , 1999 .

[7]  R. B. Fleming,et al.  The Effect of Flow Distribution in Parallel Channels of Counterflow Heat Exchangers , 1967 .

[8]  F. Mendoza Santoyo,et al.  An optimum velocimetry data display method , 2000 .

[9]  Yanzhong Li,et al.  Study of flow distribution and its improvement on the header of plate-fin heat exchanger , 2004 .

[10]  A. London,et al.  Compact heat exchangers , 1960 .

[11]  M. D. Atrey,et al.  Performance evaluation of counter flow heat exchangers considering the effect of heat in leak and longitudinal conduction for low-temperature applications , 2000 .

[12]  Ignacio E. Grossmann,et al.  Simultaneous optimization models for heat integration—I. Area and energy targeting and modeling of multi-stream exchangers , 1990 .

[13]  Hui Meng,et al.  A large eddy PIV method for turbulence dissipation rate estimation , 2000 .

[14]  Zhang Rui,et al.  Experimental Investigation on Fluid Flow Maldistribution in Plate-Fin Heat Exchangers , 2003 .

[15]  J. Westerweel Fundamentals of digital particle image velocimetry , 1997 .

[16]  Gail Duursma,et al.  PIV investigations of flow structures in the fluidised bed freeboard region , 2000 .