A radial flow microfluidic device for ultra-high-throughput affinity-based isolation of circulating tumor cells.

Circulating tumor cells (CTCs) are believed to play an important role in metastasis, a process responsible for the majority of cancer-related deaths. But their rarity in the bloodstream makes microfluidic isolation complex and time-consuming. Additionally the low processing speeds can be a hindrance to obtaining higher yields of CTCs, limiting their potential use as biomarkers for early diagnosis. Here, a high throughput microfluidic technology, the OncoBean Chip, is reported. It employs radial flow that introduces a varying shear profile across the device, enabling efficient cell capture by affinity at high flow rates. The recovery from whole blood is validated with cancer cell lines H1650 and MCF7, achieving a mean efficiency >80% at a throughput of 10 mL h(-1) in contrast to a flow rate of 1 mL h(-1) standardly reported with other microfluidic devices. Cells are recovered with a viability rate of 93% at these high speeds, increasing the ability to use captured CTCs for downstream analysis. Broad clinical application is demonstrated using comparable flow rates from blood specimens obtained from breast, pancreatic, and lung cancer patients. Comparable CTC numbers are recovered in all the samples at the two flow rates, demonstrating the ability of the technology to perform at high throughputs.

[1]  Weihong Tan,et al.  Aptamer-enabled efficient isolation of cancer cells from whole blood using a microfluidic device. , 2012, Analytical chemistry.

[2]  K. Isselbacher,et al.  Isolation of circulating tumor cells using a microvortex-generating herringbone-chip , 2010, Proceedings of the National Academy of Sciences.

[3]  Michael L Pearl,et al.  Clinical significance of circulating tumor cells detected by an invasion assay in peripheral blood of patients with ovarian cancer. , 2009, Gynecologic oncology.

[4]  Hongtao Feng,et al.  High throughput capture of circulating tumor cells using an integrated microfluidic system. , 2013, Biosensors & bioelectronics.

[5]  Caroline Dive,et al.  Circulating tumor cells as a window on metastasis biology in lung cancer. , 2011, The American journal of pathology.

[6]  Yitshak Zohar,et al.  A high-performance microsystem for isolating circulating tumor cells. , 2011, Lab on a chip.

[7]  J. Chalmers,et al.  Binding affinities/avidities of antibody–antigen interactions: Quantification and scale‐up implications , 2006, Biotechnology and bioengineering.

[8]  Chunsheng Jiang,et al.  Microfluidics and circulating tumor cells. , 2013, The Journal of molecular diagnostics : JMD.

[9]  Paul I. Okagbare,et al.  Highly efficient capture and enumeration of low abundance prostate cancer cells using prostate‐specific membrane antigen aptamers immobilized to a polymeric microfluidic device , 2009, Electrophoresis.

[10]  Jaap M. J. den Toonder,et al.  Circulating tumor cells: the Grand Challenge. , 2011, Lab on a chip.

[11]  Paul I. Okagbare,et al.  Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor. , 2008, Journal of the American Chemical Society.

[12]  Alison Stopeck,et al.  Circulating tumor cells, disease progression, and survival in metastatic breast cancer. , 2004, The New England journal of medicine.

[13]  Jason P. Gleghorn,et al.  Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody. , 2010, Lab on a chip.

[14]  Daniel F. Hayes,et al.  Sensitive capture of circulating tumour cells by functionalised graphene oxide nanosheets , 2013, Nature nanotechnology.

[15]  Zhongliang Tang,et al.  Efficient capture of circulating tumor cells with a novel immunocytochemical microfluidic device. , 2011, Biomicrofluidics.

[16]  Mehmet Toner,et al.  Biopolymer system for cell recovery from microfluidic cell capture devices. , 2012, Analytical chemistry.

[17]  Mehmet Toner,et al.  Antibody-functionalized fluid-permeable surfaces for rolling cell capture at high flow rates. , 2012, Biophysical journal.

[18]  C. Lim,et al.  Isolation and retrieval of circulating tumor cells using centrifugal forces , 2013, Scientific Reports.

[19]  Eugene J. Lim,et al.  Microfluidic, marker-free isolation of circulating tumor cells from blood samples , 2014, Nature Protocols.

[20]  G. Doyle,et al.  Significance of Circulating Tumor Cells Detected by the CellSearch System in Patients with Metastatic Breast Colorectal and Prostate Cancer , 2009, Journal of oncology.

[21]  Tony J. Pircher,et al.  Detection of EpCAM-Negative and Cytokeratin-Negative Circulating Tumor Cells in Peripheral Blood , 2011, Journal of oncology.

[22]  Kazunori Hoshino,et al.  Microchip-based immunomagnetic detection of circulating tumor cells. , 2011, Lab on a chip.

[23]  Mehmet Toner,et al.  Discontinuous nanoporous membranes reduce non-specific fouling for immunoaffinity cell capture. , 2013, Small.

[24]  G. Hampton,et al.  Evaluation of Circulating Tumor Cells and Circulating Tumor DNA in Non–Small Cell Lung Cancer: Association with Clinical Endpoints in a Phase II Clinical Trial of Pertuzumab and Erlotinib , 2011, Clinical Cancer Research.

[25]  Mehmet Toner,et al.  Detection of mutations in EGFR in circulating lung-cancer cells. , 2008, The New England journal of medicine.

[26]  G. Giaccone,et al.  Phase II Study of Single-Agent Navitoclax (ABT-263) and Biomarker Correlates in Patients with Relapsed Small Cell Lung Cancer , 2012, Clinical Cancer Research.

[27]  P. Paterlini-Bréchot,et al.  Circulating tumor cells (CTC) detection: clinical impact and future directions. , 2007, Cancer letters.

[28]  L Khoja,et al.  A pilot study to explore circulating tumour cells in pancreatic cancer as a novel biomarker , 2011, British Journal of Cancer.

[29]  Gyan Bhanot,et al.  Single Cell Profiling of Circulating Tumor Cells: Transcriptional Heterogeneity and Diversity from Breast Cancer Cell Lines , 2012, PloS one.

[30]  S. Digumarthy,et al.  Isolation of rare circulating tumour cells in cancer patients by microchip technology , 2007, Nature.

[31]  Mehmet Toner,et al.  The CTC-chip: an exciting new tool to detect circulating tumor cells in lung cancer patients. , 2009, Journal of thoracic oncology : official publication of the International Association for the Study of Lung Cancer.

[32]  Jia Fan,et al.  Circulating tumor cells: advances in detection methods, biological issues, and clinical relevance , 2011, Journal of Cancer Research and Clinical Oncology.

[33]  Mehmet Toner,et al.  Inertial Focusing for Tumor Antigen–Dependent and –Independent Sorting of Rare Circulating Tumor Cells , 2013, Science Translational Medicine.