CT metal artifact reduction method correcting for beam hardening and missing projections

We present and validate a computed tomography (CT) metal artifact reduction method that is effective for a wide spectrum of clinical implant materials. Projections through low-Z implants such as titanium were corrected using a novel physics correction algorithm that reduces beam hardening errors. In the case of high-Z implants (dental fillings, gold, platinum), projections through the implant were considered missing and regularized iterative reconstruction was performed. Both algorithms were combined if multiple implant materials were present. For comparison, a conventional projection interpolation method was implemented. In a blinded and randomized evaluation, ten radiation oncologists ranked the quality of patient scans on which the different methods were applied. For scans that included low-Z implants, the proposed method was ranked as the best method in 90% of the reviews. It was ranked superior to the original reconstruction (p = 0.0008), conventional projection interpolation (p < 0.0001) and regularized limited data reconstruction (p = 0.0002). All reviewers ranked the method first for scans with high-Z implants, and better as compared to the original reconstruction (p < 0.0001) and projection interpolation (p = 0.004). We conclude that effective reduction of CT metal artifacts can be achieved by combining algorithms tailored to specific types of implant materials.

[1]  Gary H. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981 .

[2]  M Goitein,et al.  Compensating for heterogeneities in proton radiation therapy. , 1984, Physics in medicine and biology.

[3]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .

[4]  Jerry L. Prince,et al.  Constrained sinogram restoration for limited-angle tomography , 1990 .

[5]  L. Rudin,et al.  Nonlinear total variation based noise removal algorithms , 1992 .

[6]  Patrick Dupont,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998 .

[7]  Gyula Faigel,et al.  X-Ray Holography , 1999 .

[8]  S. Zhao,et al.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses , 2000, IEEE Transactions on Medical Imaging.

[9]  L. Gerward,et al.  X-ray absorption in matter. Reengineering XCOM , 2001 .

[10]  Joseph A O'Sullivan,et al.  Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction. , 2002, Medical physics.

[11]  W. Kalender,et al.  A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images , 2004, European Radiology.

[12]  Yurii Nesterov,et al.  Smooth minimization of non-smooth functions , 2005, Math. Program..

[13]  Luc Beaulieu,et al.  Correction of CT artifacts and its influence on Monte Carlo dose calculations. , 2007, Medical physics.

[14]  Thorsten M. Buzug,et al.  Evaluation of surrogate data quality in sinogram-based CT metal-artifact reduction , 2008, Optical Engineering + Applications.

[15]  David Faul,et al.  Suppression of Metal Artifacts in CT Using a Reconstruction Procedure That Combines MAP and Projection Completion , 2009, IEEE Transactions on Medical Imaging.

[16]  Jacob Geleijns,et al.  Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT. , 2010, Medical physics.

[17]  Rainer Raupach,et al.  Normalized metal artifact reduction (NMAR) in computed tomography. , 2010, Medical physics.

[18]  Denis Laurendeau,et al.  An algorithm for efficient metal artifact reductions in permanent seed. , 2010, Medical physics.

[19]  L. Xing,et al.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization. , 2011, Medical physics.

[20]  Mehran Yazdi,et al.  An opposite view data replacement approach for reducing artifacts due to metallic dental objects. , 2011, Medical physics.

[21]  D. Fleischmann,et al.  Evaluation of two iterative techniques for reducing metal artifacts in computed tomography. , 2011, Radiology.

[22]  Emmanuel J. Candès,et al.  NESTA: A Fast and Accurate First-Order Method for Sparse Recovery , 2009, SIAM J. Imaging Sci..