Design and Atomization Properties for an Inside‐Out Type Effervescent Atomizer

Atomization of aqueous polymer solutions is a key step in the formulation of several pharmaceutical products. Droplet size control is essential in order to produce pharmaceutical products with the desired properties. The purpose of this paper is to investigate design issues for an inside‐out type of effervescent atomizer used to spray water and aqueous solutions of polyvinylpyrrolidone (Kollidon® K‐30) and hydroxypropyl methylcellulose (Pharmacoat® 603). The atomizer was operated at air‐to‐liquid mass ratios of 0.1, 0.3, and 0.5 and a feed pressure of 1172 kPa. Fluid viscosities ranged from 1 to 47 mPa.s. The influence of several atomizer design features was considered, including exit orifice length‐to‐diameter ratio, exit orifice diameter, the total area of the air injection holes, the distance between the air injection point and the exit orifice, the diameter of the mixing chamber, and the orientation of both air and liquid flows. Droplet size distributions were shown to vary significantly with the atomizer's exit orifice diameter, air injector design, and air injector distance to the exit orifice. In all cases air‐to‐liquid mass ratio played a key role in the mean droplet size. The design of the atomizer was shown to have the most pronounced effect on the mean droplet size at the lowest air‐to‐liquid mass ratios. Optimization of the atomizer design is very important in order to obtain small droplet sizes in pharmaceutical processes where the amount of air/gas should be minimized, e.g., closed‐cycle spray drying and agglomeration processes.

[1]  M. Plesniak,et al.  Entrainment by Ligament-Controlled Effervescent Atomizer-Produced Sprays , 1997, Proceedings of the 52nd INDUSTRIAL WASTE CONFERENCE May 5–7, 1997.

[2]  P. Sojka,et al.  Effervescent Atomization of Aqueous Polymer Solutions and Dispersions , 2001, Pharmaceutical development and technology.

[3]  M. Plesniak,et al.  LIGAMENT-CONTROLLED EFFERVESCENT ATOMIZATION , 1997 .

[4]  Arthur H. Lefebvre,et al.  Some Recent Developments in Twin-Fluid Atomization , 1996 .

[5]  Jouko Yliruusi,et al.  Droplet size measurement: I. Effect of three independent variables on droplet size distribution and spray angle from a pneumatic nozzle , 1995 .

[6]  P. Giunchedi,et al.  Spray-drying as a preparation method of microparticulate drug delivery systems: an overview , 1995 .

[7]  A. Lefebvre,et al.  DISCHARGE COEFFICIENTS FOR PLAIN-ORIFICE EFFERVESCENT ATOMIZERS , 1994 .

[8]  J. S. Chin,et al.  A Design Procedure for Effervescent Atomizers , 1993 .

[9]  J. S. Chin,et al.  FLOW PATTERNS IN INTERNAL-MIXING, TWIN-FLUID ATOMIZERS , 1993 .

[10]  A. Lefebvre TWIN-FLUID ATOMIZATION: FACTORS INFLUENCING MEAN DROP SIZE , 1992 .

[11]  Christopher T. Rhodes,et al.  The spray drying of pharmaceuticals , 1992 .

[12]  Paul E. Sojka,et al.  EFFERVESCENT ATOMIZATION OF HIGH-VISCOSITY FLUIDS: PART II. NON-NEWTONIAN LIQUIDS , 1991 .

[13]  J. S. Chin,et al.  Influence of Gas-Injector Geometry on Atomization Performance of Aerated-Liquid Nozzles , 1989 .

[14]  Arthur H. Lefebvre,et al.  Studies on Aerated-Liquid Atomization , 1989 .

[15]  Arthur H. Lefebvre,et al.  Spray characteristics of aerated-liquid pressure atomizers , 1988 .

[16]  L G Dodge,et al.  Calibration of the Malvern particle sizer. , 1984, Applied optics.

[17]  Arthur H. Lefebvre,et al.  The Influence of Air and Liquid Properties on Airblast Atomization , 1975 .