Prepolarized magnetic resonance imaging around metal orthopedic implants
暂无分享,去创建一个
Albert Macovski | Greig C Scott | Garry E Gold | Nicholas J Giori | Steven M Conolly | Sharon E Ungersma | A. Macovski | G. Gold | S. Conolly | G. Scott | N. Giori | R. Venook | Nathaniel I Matter | Ross D Venook | S. Ungersma | Meena Ramachandran | N. Matter | M. Ramachandran | S. E. Ungersma
[1] S. Skare,et al. Correction of MR image distortions induced by metallic objects using a 3D cubic B‐spline basis set: Application to stereotactic surgical planning , 2005, Magnetic resonance in medicine.
[2] Hollis G Potter,et al. Magnetic resonance imaging after total hip arthroplasty: evaluation of periprosthetic soft tissue. , 2004, The Journal of bone and joint surgery. American volume.
[3] R. Laskin,et al. Magnetic Resonance Imaging of Total Knee Arthroplasty , 2003, Clinical orthopaedics and related research.
[4] M A Moerland,et al. Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D. , 1994, Magnetic resonance imaging.
[5] Z H Cho,et al. Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting. , 1988, Medical physics.
[6] L W Hedlund,et al. Dynamics of magnetization in hyperpolarized gas MRI of the lung , 1997, Magnetic resonance in medicine.
[7] A. Mackay,et al. Metal artifact reduction sequence: early clinical applications. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.
[8] E. Melhem,et al. MR imaging of soft tissues adjacent to orthopaedic hardware: techniques to minimize susceptibility artefact. , 1997, Clinical radiology.
[9] J Hennig,et al. RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.
[10] A E Gross,et al. Complications of total hip arthroplasty: MR imaging-initial experience. , 2000, Radiology.
[11] K Farahani,et al. Effect of field strength on susceptibility artifacts in magnetic resonance imaging. , 1990, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.
[12] L. Hedlund,et al. MR Imaging with Hyperpolarized 3He Gas , 1995, Magnetic resonance in medicine.
[13] K. Nicolay,et al. MRI of hip prostheses using single-point methods: in vitro studies towards the artifact-free imaging of individuals with metal implants. , 2004, Magnetic resonance imaging.
[14] A Macovski,et al. Novel approaches to low‐cost MRI , 1993, Magnetic resonance in medicine.
[15] S. Brockstedt,et al. Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: Dependence on field strength (1.5 and 3 T) and imaging parameters , 2005, Journal of magnetic resonance imaging : JMRI.
[16] Martin P. Mintchev,et al. Improving geometric accuracy in the presence of susceptibility difference artifacts produced by metallic implants in magnetic resonance imaging , 2005, IEEE Transactions on Medical Imaging.
[17] Yu-Chung N. Cheng,et al. Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .
[18] Qing-San Xiang,et al. Quantitative evaluation of metal artifact reduction techniques , 2004, Journal of magnetic resonance imaging : JMRI.
[19] A Guermazi,et al. Metallic artefacts in MR imaging: effects of main field orientation and strength. , 2003, Clinical radiology.
[20] A Macovski,et al. A readout magnet for prepolarized MRI , 1996, Magnetic resonance in medicine.
[21] John S Leigh,et al. Quantifying arbitrary magnetic susceptibility distributions with MR , 2004, Magnetic resonance in medicine.
[22] P. Jezzard,et al. Correction for geometric distortion in echo planar images from B0 field variations , 1995, Magnetic resonance in medicine.
[23] M. O’Donnell,et al. NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. , 1985, Medical physics.
[24] P. Röschmann,et al. Susceptibility artefacts in NMR imaging. , 1985, Magnetic resonance imaging.
[25] D. Meier,et al. MR Imaging of Large Nonferromagnetic Metallic Implants at 1.5 T , 1987, Journal of computer assisted tomography.
[26] Albert Macovski,et al. Rapid polarizing field cycling in magnetic resonance imaging , 2006, IEEE Transactions on Medical Imaging.
[27] K. Sekihara,et al. Image restoration from non-uniform magnetic field influence for direct Fourier NMR imaging. , 1984, Physics in medicine and biology.
[28] D B Plewes,et al. Nonsusceptibility artifacts due to metallic objects in MR imaging , 1995, Journal of magnetic resonance imaging : JMRI.
[29] J. Schenck. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. , 1996, Medical physics.
[30] Petros Martirosian,et al. Metal artifacts caused by gradient switching , 2005, Magnetic resonance in medicine.
[31] Kim Butts,et al. Reduction of blurring in view angle tilting MRI , 2005, Magnetic resonance in medicine.
[32] Takashi Inoue,et al. Quantification of susceptibility artifacts produced on high-field magnetic resonance images by various biomaterials used for neurosurgical implants. Technical note. , 2002, Journal of neurosurgery.
[33] S Li,et al. A computer simulation of the static magnetic field distribution in the human head , 1995, Magnetic resonance in medicine.
[34] S A Gronemeyer,et al. Improved MR imaging for patients with metallic implants. , 2000, Magnetic resonance imaging.
[35] Steven Kurtz,et al. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. , 2005, The Journal of bone and joint surgery. American volume.
[36] W. Happer,et al. Biological magnetic resonance imaging using laser-polarized 129Xe , 1994, Nature.