Exploring the electrical wiring of screen-printed configurations utilised in electroanalysis

In this technical note the often overlooked issue of electrically connecting screen-printed electrode sensors is considered. The electrical connection of screen-printed electrodes to the potentiostat/electronics can be a main issue when a true electrochemical response is trying to be obtained and if one does not have a stable electrical connection, the results that are obtained may lack reproducibility and therefore maybe discredited as “another failed electrochemical probe/analyte”. This paper considers the case of electrically connecting screen-printed with crocodile clips and compares that to the use of edge-connectors demonstrating the precise connection of an electrode setup when utilising crocodile clips can result in extremely reproducible electrochemical outputs when applied correctly.

[1]  G. Whitesides,et al.  Regeneration of nicotinamide cofactors for use in organic synthesis , 1987, Applied biochemistry and biotechnology.

[2]  J. F. Stevens,et al.  Vitamins C and E: beneficial effects from a mechanistic perspective. , 2011, Free radical biology & medicine.

[3]  John P. Hart,et al.  Screen-printed electrochemical sensors for monitoring metal pollutants , 2003 .

[4]  Jonathan P. Metters,et al.  New directions in screen printed electroanalytical sensors: an overview of recent developments. , 2011, The Analyst.

[5]  D. A. Brownson,et al.  Crime scene investigation III: Exploring the effects of drugs of abuse and neurotransmitters on Bloodstain Pattern Analysis , 2012 .

[6]  G. Palleschi,et al.  Part I: A comparative study of bismuth-modified screen-printed electrodes for lead detection. , 2011, Analytica chimica acta.

[7]  Jonathan P. Metters,et al.  Forensic electrochemistry: sensing the molecule of murder atropine. , 2013, The Analyst.

[8]  Joseph Wang Carbon‐Nanotube Based Electrochemical Biosensors: A Review , 2005 .

[9]  Zhaoxia Wang,et al.  Electrochemical detection of dopamine in the presence of epinephrine, uric acid and ascorbic acid using a graphene-modified electrode , 2012 .

[10]  Richard S. Nicholson,et al.  Theory and Application of Cyclic Voltammetry for Measurement of Electrode Reaction Kinetics. , 1965 .

[11]  René Wurmser,et al.  Oxidation-reduction potentials of organic systems , 1960 .

[12]  María Begoña González García,et al.  Comparative study of different alcohol sensors based on Screen-Printed Carbon Electrodes. , 2012, Analytica chimica acta.

[13]  Jonathan P. Metters,et al.  Paper-based electroanalytical sensing platforms , 2013 .

[14]  J. Zen,et al.  Electrochemical investigation of glucose sensor fabricated at copper-plated screen-printed carbon electrodes , 2002 .

[15]  John P. Hart,et al.  Screen‐printed voltammetric and amperometric electrochemical sensors for decentralized testing , 1994 .

[16]  J. Hart,et al.  The Electrochemical Behavior of Nitrazepam at a Screen-Printed Carbon Electrode and Its Determination in Beverages by Adsorptive Stripping Voltammetry , 2009 .

[17]  Guangying Zhao,et al.  A disposable electrochemical immunosensor arrays using 4-channel screen-printed carbon electrode for simultaneous detection of Escherichia coli O157:H7 and Enterobacter sakazakii , 2013 .

[18]  Jonathan P. Metters,et al.  The fabrication, characterisation and electrochemical investigation of screen-printed graphene electrodes. , 2014, Physical chemistry chemical physics : PCCP.

[19]  J. F. Rinehart,et al.  THE DETECTION OF SUBCLINICAL SCURVY OR VITAMIN C DEFICIENCY , 1942 .

[20]  Hui Zhang,et al.  An electrochemical biosensor for determination of ascorbic acid by cobalt (II) phthalocyanine–multi-walled carbon nanotubes modified glassy carbon electrode , 2012 .

[21]  Rashid O. Kadara,et al.  Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples. , 2008, Analytica chimica acta.

[22]  R. Antiochia,et al.  An Extended Method for the Practical Evaluation of the Standard Rate Constant from Cyclic Voltammetric Data , 2004 .

[23]  Y. Long,et al.  Recent developments and applications of screen-printed electrodes in environmental assays--a review. , 2012, Analytica chimica acta.

[24]  J. Hart,et al.  Voltammetric behaviour of ascorbic acid at a graphite-epoxy composite electrode chemically modified with cobalt phthalocyanine and its amperometric determination in multivitamin preparations , 1990 .

[25]  Dirk Inzé,et al.  Plant L‐ascorbic acid: chemistry, function, metabolism, bioavailability and effects of processing , 2000 .

[26]  C. Castelletti,et al.  Electrochemical DNA biosensor for bovine papillomavirus detection using polymeric film on screen-printed electrode. , 2012, Biosensors & bioelectronics.

[27]  Jonathan P. Metters,et al.  Cobalt Phthalocyanine Modified Electrodes Utilised in Electroanalysis: Nano-Structured Modified Electrodes vs. Bulk Modified Screen-Printed Electrodes , 2014, Sensors.

[28]  Rodkey Fl Oxidation-reduction potentials of the diphosphopyridine nucleotide system. , 1952 .

[29]  J. Hart,et al.  The redox behaviour of diazepam (Valium®) using a disposable screen-printed sensor and its determination in drinks using a novel adsorptive stripping voltammetric assay. , 2013, Talanta.

[30]  Jonathan P. Metters,et al.  Electroanalytical sensing of chromium(III) and (VI) utilising gold screen printed macro electrodes. , 2012, The Analyst.

[31]  Jonathan P. Metters,et al.  Forensic electrochemistry applied to the sensing of new psychoactive substances: electroanalytical sensing of synthetic cathinones and analytical validation in the quantification of seized street samples. , 2014, Analytical chemistry.

[32]  R. Yu,et al.  Pressed-pellet solid potentiometric sensor for ascorbic acid based on derivatives of cobalt(II) phthalocyanine doped with iodine , 1996 .