Fabrication of Polymer Microneedle Electrodes Coated with Nanoporous Parylene

In this study, we demonstrate the fabrication of polymer microneedle electrodes covered with a nanoporous parylene film that can serve as flexible electrodes for a brain–machine interface. In brain wave measurement, the electric impedance of electrodes should be below 10 kΩ at 15 Hz, and the conductive layer needs to be protected to survive its insertion into the stratum corneum. Polymer microneedles can be used as substrates for flexible electrodes, which can compensate for the movement of the skin; however, the adhesion between a conductive metal film, such as a silver film, and a polymer, such as poly(dimethylsiloxane) (PDMS), is weak. Therefore, we coated the electrode surface with a nanoporous parylene film, following the vapor deposition of a silver film. When the porosity of the parylene film is appropriate, it protects the silver film while allowing the electrode to have sufficient conductivity. The porosity can be controlled by adjusting the amount of the parylene dimer used for the deposition or the parylene film thickness. We experimentally verified that a conductive membrane was successfully protected while maintaining a conductivity below 10 kΩ when the thickness of the parylene film was between 25 and 38 nm.

[1]  K. Mabuchi,et al.  Parylene flexible neural probes integrated with microfluidic channels. , 2005, Lab on a chip.

[2]  E. Schmidt,et al.  Laser exposure of Parylene-C insulated microelectrodes , 1995, Journal of Neuroscience Methods.

[3]  L. Kirkup,et al.  A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.

[4]  Norihisa Miki,et al.  A Flexible Capacitive Sensor with Encapsulated Liquids as Dielectrics , 2012, Micromachines.

[5]  Polyethersulfone Membrane Coated With Nanoporous Parylene for Ultrafiltration , 2012, Journal of Microelectromechanical Systems.

[6]  M. Bikson,et al.  Transcranial current stimulation focality using disc and ring electrode configurations: FEM analysis , 2008, Journal of neural engineering.

[7]  José Higino Correia,et al.  New dry electrodes based on iridium oxide (IrO) for non-invasive biopotential recordings and stimulation , 2010 .

[8]  D. Tucker,et al.  Scalp electrode impedance, infection risk, and EEG data quality , 2001, Clinical Neurophysiology.

[9]  Norihisa Miki,et al.  Three-dimensional spheroid-forming lab-on-a-chip using micro-rotational flow , 2010 .

[10]  Andrew S. Whitford,et al.  Cortical control of a prosthetic arm for self-feeding , 2008, Nature.

[11]  G. Whitesides,et al.  Soft lithography for micro- and nanoscale patterning , 2010, Nature Protocols.

[12]  A. Gruetzmann,et al.  Novel dry electrodes for ECG monitoring , 2007, Physiological measurement.

[13]  G. Pfurtscheller,et al.  Brain-Computer Interfaces for Communication and Control. , 2011, Communications of the ACM.

[14]  Florian Solzbacher,et al.  Encapsulation of an Integrated Neural Interface Device With Parylene C , 2009, IEEE Transactions on Biomedical Engineering.

[15]  Francis E. H. Tay,et al.  A microfabricated electrode with hollow microneedles for ECG measurement , 2009 .

[16]  J. Yeh,et al.  Patterning of poly-para-xylylenes by reactive ion etching , 1983 .

[17]  Norihisa Miki,et al.  Formation of polymer microneedle arrays using soft lithography , 2011 .

[18]  J. Ohta,et al.  The development of a multichannel electrode array for retinal prostheses , 2006, Journal of Artificial Organs.

[19]  I. Shimoyama,et al.  A three-dimensional shape memory alloy microelectrode with clipping structure for insect neural recording , 2000, Journal of Microelectromechanical Systems.

[20]  George M. Whitesides,et al.  Replica molding using polymeric materials: A practical step toward nanomanufacturing , 1997 .

[21]  Marcelo Haberman,et al.  Insulating electrodes: a review on biopotential front ends for dielectric skin–electrode interfaces , 2010, Physiological measurement.

[22]  Peter Enoksson,et al.  Micromachined electrodes for biopotential measurements , 2001 .

[23]  Effect of Tension and Curvature of Skin on Insertion Characteristics of Microneedle Array , 2010 .

[24]  Göran Stemme,et al.  Characterization of micromachined spiked biopotential electrodes , 2002, IEEE Transactions on Biomedical Engineering.

[25]  Tony J Collins,et al.  ImageJ for microscopy. , 2007, BioTechniques.

[26]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[27]  R. Andersen,et al.  Selecting the signals for a brain–machine interface , 2004, Current Opinion in Neurobiology.

[28]  M. Nuttin,et al.  A brain-actuated wheelchair: Asynchronous and non-invasive Brain–computer interfaces for continuous control of robots , 2008, Clinical Neurophysiology.