Novel Broadband Calibration Method of Current Shunts Based on VNA

Usually high wideband ac current and harmonics measurements are accurately achieved in industry and laboratories by using high accuracy shunts or standard shunts. For particular applications, such as power and transient measurements, it is mandatory to evaluate the shunt impedance phase and magnitude according to the frequency bandwidth of interest before to measure the current with such sensors. High electrical current shunt beyond 1 A is calibrated in magnitude up to 100 kHz and in phase angle up to 200 kHz only by a few National Metrology Institutes. The existing traceable measurement methods to characterize these sensors are limited in frequency to 100 kHz, with expanded uncertainties of the ac–dc difference (magnitude) and the phase angle of more than $5 \times 10^{-6}$ and $62~\mu $ rad at 100 kHz, respectively. A new traceable calibration method to measure and characterize current shunts at high frequencies is presented in this paper. This measurement method is based on the use of a vector network analyzer. The measurements are presented up to 60 MHz, but theoretically, the presented method does not exhibit a specific frequency limitation. Only the characteristics of the shunt under study can impose limitation in practice. While uncertainties are higher than those provided by the existing methods, the method presented in this paper is the only method able to perform in one step a broadband and simultaneous measurement of the magnitude and phase of current shunts up to few megahertz with acceptable uncertainties.

[2]  K.-E. Rydler High precision automated measuring system for AC-DC current transfer standards , 1993 .

[3]  Biao Wang,et al.  Measurement of the Phase Angle Errors of High Current Shunts at Frequencies up to 100 kHz , 2013, IEEE Transactions on Instrumentation and Measurement.

[4]  Gert Rietveld,et al.  Phase Comparison of High-Current Shunts up to 100 kHz , 2011, IEEE Transactions on Instrumentation and Measurement.

[5]  Thomas E. Lipe,et al.  AC-DC difference relationships for current shunt and thermal converter combinations , 1990 .

[6]  M. Klonz,et al.  Quartz planar multijunction thermal converter as a new AC-DC current transfer standard up to 1 MHz , 2004, CPEM 2004.

[7]  Ilya Budovsky,et al.  Measurement of Phase Angle Errors of Precision Current Shunts in the Frequency Range From 40 Hz to 200 kHz , 2007, IEEE Transactions on Instrumentation and Measurement.

[9]  S. Svensson,et al.  Improved Model and Phase-Angle Verification of Current Shunts for AC And Power Measurements , 2004, 2004 Conference on Precision Electromagnetic Measurements.

[10]  Djamel Allal,et al.  Primary Standard for S-Parameter Measurements at Intermediate Frequencies (IFs) , 2013, IEEE Transactions on Instrumentation and Measurement.

[11]  R. Lapuh,et al.  Modeling of AC/DC current shunts , 2010, CPEM 2010.

[12]  Bruno Trinchera,et al.  Wideband digital phase comparator for high current shunts , 2011, 1110.0866.

[13]  V. Tarasso,et al.  A Method to Determine the Phase Angle Errors of an Impedance Meter , 2004, 2004 Conference on Precision Electromagnetic Measurements.

[14]  V. Tarasso,et al.  Determination of phase angle errors of current shunts for wideband power measurement , 2012, 2012 Conference on Precision electromagnetic Measurements.

[15]  I. Budovsky,et al.  A high-frequency thermal power comparator , 1998, 1998 Conference on Precision Electromagnetic Measurements Digest (Cat. No.98CH36254).

[16]  A. Ferrero,et al.  Two-port network analyzer calibration using an unknown 'thru' , 1992, IEEE Microwave and Guided Wave Letters.

[17]  Harald Slinde,et al.  Design, Modeling, and Verification of High-Performance AC–DC Current Shunts From Inexpensive Components , 2008, IEEE Transactions on Instrumentation and Measurement.