Referenceless phase velocity mapping using balanced SSFP

Phase contrast MRI (PC‐MRI) is an established technique for measuring blood flow velocities in vivo. Although spoiled gradient recalled echo (GRE) PC‐MRI is the most widely used pulse sequence today, balanced steady state free precession (SSFP) PC‐MRI has been shown to produce accurate velocity estimates with superior SNR efficiency. We propose a referenceless approach to flow imaging that exploits the intrinsic refocusing property of balanced SSFP, and achieves up to a 50% reduction in total scan time. With the echo time set to exactly one half of the sequence repetition time (TE = TR/2), we show that non‐flow‐related image phase tends to vary smoothly across the field‐of‐view, and can be estimated from static tissue regions to produce a phase reference for nearby voxels containing flowing blood. This approach produces accurate in vivo one‐dimensional velocity estimates in half the scan time compared with conventional balanced SSFP phase‐contrast methods. We also demonstrate the feasibility of referenceless time‐resolved 3D flow imaging (called “7D” flow) in the carotid bifurcation from just three acquisitions. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

[1]  P. R. Moran A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.

[2]  Shantanu Sinha,et al.  In‐plane velocity encoding with coherent steady‐state imaging , 2005, Magnetic resonance in medicine.

[3]  N J Pelc,et al.  Flow effects in balanced steady state free precession imaging , 2003, Magnetic resonance in medicine.

[4]  Vinay M Pai Phase contrast using multiecho steady‐state free precession , 2007, Magnetic resonance in medicine.

[5]  Patrick Le Roux,et al.  Simplified model and stabilization of SSFP sequences. , 2003, Journal of magnetic resonance.

[6]  N J Pelc,et al.  Quantitative magnetic resonance flow imaging. , 1994, Magnetic resonance quarterly.

[8]  E. Hahn,et al.  Detection of sea‐water motion by nuclear precession , 1960 .

[9]  Dwight G Nishimura,et al.  Fast phase‐contrast velocity measurement in the steady state , 2002, Magnetic resonance in medicine.

[10]  N J Pelc,et al.  Balanced phase‐contrast steady‐state free precession (PC‐SSFP): A novel technique for velocity encoding by gradient inversion , 2003, Magnetic resonance in medicine.

[11]  Michael Markl,et al.  On flow effects in balanced steady‐state free precession imaging: Pictorial description, parameter dependence, and clinical implications , 2004, Journal of magnetic resonance imaging : JMRI.

[12]  R. Herfkens,et al.  Phase contrast cine magnetic resonance imaging. , 1991, Magnetic resonance quarterly.

[13]  K. Scheffler,et al.  Is TrueFISP a gradient‐echo or a spin‐echo sequence? , 2003, Magnetic resonance in medicine.

[14]  John M Pauly,et al.  Referenceless PRF shift thermometry , 2004, Magnetic resonance in medicine.

[15]  J. Pauly,et al.  Nonsubtractive spiral phase contrast velocity imaging , 1999, Magnetic resonance in medicine.