Requirements for mesh resolution in 3D computational hemodynamics.

Computational techniques are widely used for studying large artery hemodynamics. Current trends favor analyzing flow in more anatomically realistic arteries. A significant obstacle to such analyses is generation of computational meshes that accurately resolve both the complex geometry and the physiologically relevant flow features. Here we examine, for a single arterial geometry, how velocity and wall shear stress patterns depend on mesh characteristics. A well-validated Navier-Stokes solver was used to simulate flow in an anatomically realistic human right coronary artery (RCA) using unstructured high-order tetrahedral finite element meshes. Velocities, wall shear stresses (WSS), and wall shear stress gradients were computed on a conventional "high-resolution" mesh series (60,000 to 160,000 velocity nodes) generated with a commercial meshing package. Similar calculations were then performed in a series of meshes generated through an adaptive mesh refinement (AMR) methodology. Mesh-independent velocity fields were not very difficult to obtain for both the conventional and adaptive mesh series. However, wall shear stress fields, and, in particular, wall shear stress gradient fields, were much more difficult to accurately resolve. The conventional (nonadaptive) mesh series did not show a consistent trend towards mesh-independence of WSS results. For the adaptive series, it required approximately 190,000 velocity nodes to reach an r.m.s. error in normalized WSS of less than 10 percent. Achieving mesh-independence in computed WSS fields requires a surprisingly large number of nodes, and is best approached through a systematic solution-adaptive mesh refinement technique. Calculations of WSS, and particularly WSS gradients, show appreciable errors even on meshes that appear to produce mesh-independent velocity fields.

[1]  R Frayne,et al.  MR measurement and numerical simulation of steady flow in an end-to-side anastomosis model. , 1996, Journal of biomechanics.

[2]  C Kleinstreuer,et al.  Numerical investigation and prediction of atherogenic sites in branching arteries. , 1995, Journal of biomechanical engineering.

[3]  T Yamaguchi,et al.  Computer modeling of fluid dynamics related to a myocardial bridge in a coronary artery. , 1999, Biorheology.

[4]  Thomas J. R. Hughes,et al.  Finite element modeling of blood flow in arteries , 1998 .

[5]  C. Kleinstreuer,et al.  Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis. , 1997, Journal of vascular surgery.

[6]  C. R. Ethier,et al.  A characteristic/finite element algorithm for the 3-D Navier–Stokes equations using unstructured grids , 1999 .

[7]  C. R. Ethier,et al.  Steady flow separation patterns in a 45 degree junction , 2000, Journal of Fluid Mechanics.

[8]  Q. Long,et al.  Numerical study of blood flow in an anatomically realistic aorto‐iliac bifurcation generated from MRI data , 2000, Magnetic resonance in medicine.

[9]  T. Mullin,et al.  Nonlinear flow phenomena in a symmetric sudden expansion , 1990, Journal of Fluid Mechanics.

[10]  C. Kleinstreuer,et al.  Hemodynamic simulations and computer-aided designs of graft-artery junctions. , 1997, Journal of biomechanical engineering.

[11]  C. R. Ethier,et al.  A numerical study of blood flow patterns in anatomically realistic and simplified end-to-side anastomoses. , 1999, Journal of biomechanical engineering.

[12]  D. Hearshen,et al.  Comparison of velocity‐encoded MR imaging and fluid dynamic modeling of steady and disturbed flow , 1992, Journal of magnetic resonance imaging : JMRI.

[13]  F. Migliavacca,et al.  Calculating blood flow from Doppler measurements in the systemic-to-pulmonary artery shunt after the Norwood operation: a method based on computational fluid dynamics. , 2000, Ultrasound in medicine & biology.

[14]  C. Ross Ethier,et al.  Exact fully 3D Navier–Stokes solutions for benchmarking , 1994 .

[15]  René M. Botnar,et al.  Hemodynamics in the carotid artery bifurcation: a comparison between numerical simulations and in vitro MRI measurements. , 2000, Journal of biomechanics.

[16]  H. Schima,et al.  Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia. , 1996, Journal of biomechanics.

[17]  Einar M. Rønquist,et al.  An Operator-integration-factor splitting method for time-dependent problems: Application to incompressible fluid flow , 1990 .

[18]  C. Ross Ethier,et al.  Enhanced error estimator for adaptive finite element analysis of 3D incompressible flow , 2001 .

[19]  K B Chandran,et al.  Numerical study on the effect of secondary flow in the human aorta on local shear stresses in abdominal aortic branches. , 2000, Journal of biomechanics.

[20]  K Perktold,et al.  Blood flow in distal end-to-side anastomoses with PTFE and a venous patch: results of an in vitro flow visualisation study. , 1999, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[21]  A D Hughes,et al.  Blood flow and vessel mechanics in a physiologically realistic model of a human carotid arterial bifurcation. , 2000, Journal of biomechanics.