Quantitative muscle ultrasound in Duchenne muscular dystrophy: A comparison of techniques

Muscle pathology in Duchenne muscular dystrophy (DMD) can be quantified using ultrasound by measuring either the amplitudes of sound‐waves scattered back from the tissue [quantitative backscatter analysis (QBA)] or by measuring these backscattered amplitudes after compression into grayscale levels (GSL) obtained from the images. Methods: We measured and compared QBA and GSL from 6 muscles of 25 boys with DMD and 25 healthy subjects, aged 2‐14 years, with age and, in DMD, with function (North Star Ambulatory Assessment). Results: Both QBA and GSL were measured reliably (intraclass correlation ≥ 0.87) and were higher in DMD than controls (P < 0.0001). In DMD, average QBA and GSL measured from superficial regions of muscle increased (rho ≥ 0.47, P < 0.05) with both higher age and worse function; in contrast, GSL measured from whole regions of muscle did not. Conclusions: QBA and GSL measured from superficial regions of muscle can similarly quantify muscle pathology in DMD. Muscle Nerve 51: 207–213, 2015

[1]  R. Finkel,et al.  P3.51 Results of a Phase 2b, dose-ranging study of ataluren (PTC124®) in nonsense mutation Duchenne/Becker muscular dystrophy (nmDBMD) , 2010, Neuromuscular Disorders.

[2]  K. Bushby,et al.  Clinical outcome measures for trials in Duchenne muscular dystrophy: report from International Working Group meetings. , 2011, Clinical investigation.

[3]  Nens van Alfen,et al.  Quantitative muscle ultrasound is a promising longitudinal follow-up tool in Duchenne muscular dystrophy , 2012, Neuromuscular Disorders.

[4]  Mark R Holland,et al.  Quantitative ultrasound of skeletal muscle: reliable measurements of calibrated muscle backscatter from different ultrasound systems. , 2012, Ultrasound in medicine & biology.

[5]  C. Reimers,et al.  Calf enlargement in neuromuscular diseases: a quantitative ultrasound study in 350 patients and review of the literature , 1996, Journal of the Neurological Sciences.

[6]  Machiel J Zwarts,et al.  Muscle ultrasound in neuromuscular disorders , 2008, Muscle & nerve.

[7]  C. Zaidman,et al.  Minimal training is required to reliably perform quantitative ultrasound of muscle , 2014, Muscle & nerve.

[8]  Karl Swedberg,et al.  Six minute walk test. , 2005, European heart journal.

[9]  A. Pestronk,et al.  Calibrated quantitative ultrasound imaging of skeletal muscle using backscatter analysis , 2008, Muscle & nerve.

[10]  Baziel G M van Engelen,et al.  Skeletal muscle ultrasound: correlation between fibrous tissue and echo intensity. , 2009, Ultrasound in medicine & biology.

[11]  Seward B Rutkove,et al.  Effects of age on muscle as measured by electrical impedance myography , 2006, Physiological measurement.

[12]  M. Main,et al.  Reliability of the North Star Ambulatory Assessment in a multicentric setting , 2009, Neuromuscular Disorders.