Pole-to-Ground Fault Analysis and Fast Protection Scheme for HVDC Based on Overhead Transmission Lines

Flexible direct current (DC) transmission network technology is an effective method for large capacity clean energy access to power grids, but the DC short-circuit fault detection for it is a difficult problem. In this paper, the pole-to-ground fault transient characteristics in a multi-terminal DC power grid, based on overhead transmission lines and DC circuit breakers, are analyzed firstly. Then, a fast protection scheme is proposed according to the fault transient characteristics. Only local information is utilized for fault detection and location in the proposed scheme. Moreover, the scheme is verified to have the advantages of fast action speed, high reliability and the ability to resist the transition resistance. A four terminal DC power grid model based on actual engineering parameters is established in PSCAD/EMTDC, and the validity of the protection scheme under different fault conditions is verified by simulation results.

[1]  Boon-Teck Ooi,et al.  Locating and Isolating DC Faults in Multi-Terminal DC Systems , 2007, IEEE Transactions on Power Delivery.

[2]  吴婧,et al.  Pattern Analysis of Future HVDC Grid Development , 2014 .

[3]  P. Bauer,et al.  Analytical model of MMC-based multi-terminal HVDC grid for normal and DC fault operation , 2016, 2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia).

[4]  John E. Fletcher,et al.  Hybrid Cascaded Modular Multilevel Converter With DC Fault Ride-Through Capability for the HVDC Transmission System , 2015, IEEE Transactions on Power Delivery.

[5]  Colin Oates,et al.  Modular Multilevel Converter Design for VSC HVDC Applications , 2015, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[6]  Jin Yang,et al.  Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables , 2012, IEEE Transactions on Industrial Electronics.

[7]  P. Bauer,et al.  Fast DC fault recovery technique for H-bridge MMC-based HVDC networks , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[8]  Jiabing Hu,et al.  Analysis and Enhanced Control of Hybrid-MMC-Based HVDC Systems During Asymmetrical DC Voltage Faults , 2017, IEEE Transactions on Power Delivery.

[9]  Boon-Teck Ooi,et al.  Protection of VSC-multi-terminal HVDC against DC faults , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[10]  Xiao-Ping Zhang,et al.  Basic topology and key devices of the five-terminal DC grid , 2015 .

[11]  J. Dorn,et al.  HVDC and Power Electronic Systems for Overhead Line and Insulated Cable Applications B 4-8 Trans Bay Cable – A Breakthrough of VSC Multilevel Converters in HVDC Transmission , 2012 .

[12]  Yu Pan-Pan,et al.  Analysis of Submodule Overcurrent Caused by DC Pole-to-pole Fault in Modular Multilevel Converter HVDC System , 2011 .

[13]  Gengyin Li,et al.  Submodule configuration of HVDC-DC auto transformer considering DC fault , 2016 .

[14]  Hao Wang,et al.  Parameters optimization of DC voltage droop control based on VSC-MTDC , 2016, 2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC).

[15]  W.L. Kling,et al.  HVDC Connection of Offshore Wind Farms to the Transmission System , 2007, IEEE Transactions on Energy Conversion.

[16]  John E. Fletcher,et al.  Enhanced Flat-Topped Modulation for MMC Control in HVDC Transmission Systems , 2017, IEEE Transactions on Power Delivery.

[17]  Wang Shuai,et al.  Short-Term Energy Based Approach for Monopolar Grounding Line Identification in MMC-MTDC System , 2016 .

[18]  Zhiguo Hao,et al.  Development of a Novel Protection Device for Bipolar HVDC Transmission Lines , 2014, IEEE Transactions on Power Delivery.

[19]  Rainer Marquardt,et al.  An innovative modular multilevel converter topology suitable for a wide power range , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[20]  Stephen J. Finney,et al.  Continuous Operation of Radial Multiterminal HVDC Systems Under DC Fault , 2016, IEEE Transactions on Power Delivery.

[21]  Tan Li,et al.  DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System , 2013 .

[22]  Christian M. Franck,et al.  Fault Current Interruption in Multiterminal HVDC Networks , 2016, IEEE Transactions on Power Delivery.

[23]  Lie Xu,et al.  DC fault analysis of MMC based HVDC system for large offshore wind farm integration , 2013 .

[24]  Zheng Xu,et al.  On the Bipolar MMC-HVDC Topology Suitable for Bulk Power Overhead Line Transmission: Configuration, Control, and DC Fault Analysis , 2014, IEEE Transactions on Power Delivery.

[25]  Adam Dysko,et al.  Impact of VSC Converter Topology on Fault Characteristics in HVDC Transmission Systems , 2016 .

[26]  Liangzhong Yao,et al.  DC Fault Detection and Location in Meshed Multiterminal HVDC Systems Based on DC Reactor Voltage Change Rate , 2017, IEEE Transactions on Power Delivery.

[27]  Adam Dysko,et al.  Fault current characterisation in VSC-based HVDC systems , 2016 .

[28]  Zhao Chengyon,et al.  DC Pole-to-ground Fault Characteristic Analysis and Converter Fault Recovery Strategy of MMC-HVDC , 2014 .