Reliability of an optoelectric system to measure elbow kinematics.

Motion analysis of the upper extremity during functional activities has only recently become more accessible. An optoelectric system (WATSMART) was subjected to testing using first a calibration dummy and then human subjects. The mean differences between the system calculated angles and those measured with potentiometers on a calibration dummy were less than 1.6° in all three planes. The test-retest reliability of the system when measuring elbow motion of human subjects yielded acceptable repeatability for measurement of functional activities. Calculation of the least significant difference found that minimum differences from 4 to 14° in flexion and from 10 to 19° in rotation can be detected using the reported set-up and protocol.

[1]  R. Segal,et al.  Wrist movements in able-bodied and brain injured individuals. , 1991, Archives of physical medicine and rehabilitation.

[2]  K M Tillotson,et al.  Noninvasive Measurement of Lumbar Sagittal Mobility: An Assessment of the Flexicurve Technique , 1991, Spine.

[3]  U. Wyss,et al.  Examining the Elbow during Functional Activities , 1990 .

[4]  E. Chao,et al.  A biomechanical study of normal functional elbow motion. , 1981, The Journal of bone and joint surgery. American volume.

[5]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[6]  A. Quanbury,et al.  Normal functional range of motion of upper limb joints during performance of three feeding activities. , 1990, Archives of physical medicine and rehabilitation.

[7]  F. Verstappen,et al.  Variability and reliability of joint measurements , 1990, The American journal of sports medicine.

[8]  D. R. Fish,et al.  Sources of goniometric error at the elbow. , 1985, Physical therapy.

[9]  J. Cooke,et al.  Kinematics of arm movements in elderly humans , 1989, Neurobiology of Aging.

[10]  M M Horger,et al.  The reliability of goniometric measurements of active and passive wrist motions. , 1990, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[11]  B Stillman Computer-based video analysis of movement. , 1991, The Australian journal of physiotherapy.

[12]  S. Azen,et al.  Reliability of goniometric measurements. , 1978, Physical therapy.

[13]  R. Brumfield,et al.  A biomechanical study of normal functional wrist motion. , 1984, Clinical orthopaedics and related research.

[14]  Engen Tj,et al.  Method of kinematic study of normal upper extremity movements. , 1968 .

[15]  J. P. Scholz Reliability and validity of the WATSMART three-dimensional optoelectric motion analysis system. , 1989, Physical therapy.

[16]  R. Glisson,et al.  Functional wrist motion: a biomechanical study. , 1985, The Journal of hand surgery.

[17]  F J Bejjani,et al.  Analysis of upper-extremity performance in athletes and musicians. , 1990, Hand clinics.

[18]  J. M. Rothstein,et al.  Goniometric Reliability in a Clinical Setting , 1983 .

[19]  U P Wyss,et al.  A procedure to validate three-dimensional motion assessment systems. , 1993, Journal of biomechanics.