Real time assessment of power quality issues in 11 kV/440 V distribution feeder using distribution static synchronous compensator

The effects of power quality (PQ) issues in a distribution feeder occur due to abnormal load condition. In this paper, first, the real time PQ issues in an 11 kV/440 V distribution feeder are measured and analyzed by PQ analyzers. The sudden load fluctuations in the distribution system result in different PQ issues such as voltage sag/swell, transient, flicker and harmonics. Then, an improved interactive distribution static synchronous compensator (D-STATCOM) is installed in distribution feeder to mitigate the PQ issues. A novel control algorithm will operate the interactive D-STATCOM in voltage control mode (VCM) or current control mode (CCM). At normal operating conditions, the D-STATCOM operates in CCM, during abnormal condition the D-STATCOM will operates in VCM to mitigates the PQ issues. The D-STATCOM is modeled and simulated in MATLAB-SIMULINK environment. The field programmable gate array (FPGA)-based laboratory prototype D-STATCOM has been developed to validate the function of the controller.

[1]  Alessandro Ferrero,et al.  The impact of Internet transmission on the uncertainty in the electric power quality estimation by means of a distributed measurement system , 2003, IEEE Trans. Instrum. Meas..

[2]  Arindam Ghosh,et al.  Load compensating DSTATCOM in weak AC systems , 2003 .

[3]  A. Elnady,et al.  Unified approach for mitigating voltage sag and voltage flicker using the DSTATCOM , 2005 .

[4]  G. Wiczyński Description of voltage fluctuations in LV power network with the use of Pst indicator and voltage fluctuation indices , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[5]  S. Paramasivam,et al.  FPGA realisation of an area efficient SVPWM modulator for three phase induction motor drive , 2010 .

[6]  S. Paramasivam,et al.  Dynamically Reconfigurable PWM Controller for Three-Phase Voltage-Source Inverters , 2011, IEEE Transactions on Power Electronics.

[7]  Roberto Ottoboni,et al.  Electronic Combined Transformer for Power-Quality Measurements in High-Voltage Systems , 2011, IEEE Transactions on Instrumentation and Measurement.

[8]  K. T. Chau,et al.  Power Compensation and Power Quality Improvement Based on Multiple-Channel Current Source Converter Fed HT SMES , 2012, IEEE Transactions on Applied Superconductivity.

[9]  G. Wiczyński,et al.  Basic characteristics of IEC flickermeter processing , 2012 .

[10]  Bhavesh R. Bhalja,et al.  Comparison of control strategies for DSTATCOM in three-phase, four-wire distribution system for power quality improvement under various source voltage and load conditions , 2012 .

[11]  Kamal Al-Haddad,et al.  Comprehensive Study of DSTATCOM Configurations , 2014, IEEE Transactions on Industrial Informatics.

[12]  Chandan Kumar,et al.  A Multifunctional DSTATCOM Operating Under Stiff Source , 2014, IEEE Transactions on Industrial Electronics.

[13]  Mahesh K. Mishra,et al.  A Voltage-Controlled DSTATCOM for Power-Quality Improvement , 2014, IEEE Transactions on Power Delivery.

[14]  Narri Yadaiah,et al.  FPGA – realization of digital PWM controller using Q-format-based signal processing , 2015 .

[15]  Om Prakash Mahela,et al.  A review of distribution static compensator , 2015 .

[16]  Math Bollen,et al.  Power quality issues in the electric power system of the future , 2016 .

[17]  A. Vural Self-capacitor voltage balancing method for optimally hybrid modulated cascaded H-bridge D-STATCOM , 2016 .

[18]  Igor Papic,et al.  Simple Continuous Assessment of Transmission-Network Flicker Levels Caused by Multiple Sources , 2016 .

[19]  Paramasivam Shanmugam,et al.  Design and development of improved power quality based micro-butt welding power supply , 2017 .

[20]  M. Gonzalez-Ramirez,et al.  Variable speed drive with PFC front-end for three-phase induction motor , 2017 .

[21]  Emilio J. Palacios-Garcia,et al.  Development and application of a smart grid test bench , 2017 .

[22]  Grzegorz Wiczynski Estimation of $\boldsymbol {P}_{st}$ Indicator Values on the Basis of Voltage Fluctuation Indices , 2017, IEEE Transactions on Instrumentation and Measurement.

[23]  Daniel Lee Geiger II,et al.  Assessing Voltage Fluctuations and Lamp Flicker Using RMS Voltages , 2017, IEEE Transactions on Power Delivery.

[24]  Z. Ding,et al.  An iterative observer approach to harmonic estimation for multiple measurements in power distribution systems , 2017 .

[25]  H. Hizam,et al.  Investigation of severity of voltage flicker caused by second harmonic , 2017 .

[26]  Li Wang,et al.  Reduction of Three-Phase Voltage Unbalance Subject to Special Winding Connections of Two Single-Phase Distribution Transformers of a Microgrid System Using a Designed D-STATCOM Controller , 2018 .

[27]  Pedro Rodriguez,et al.  Control of D-STATCOM During Unbalanced Grid Faults Based on DC Voltage Oscillations and Peak Current Limitations , 2018 .

[28]  Ali Mehrizi-Sani,et al.  Design Tradeoffs in Selection of the DC-Side Voltage for a D-STATCOM , 2018, IEEE Transactions on Power Delivery.

[29]  Eklas Hossain,et al.  Analysis and Mitigation of Power Quality Issues in Distributed Generation Systems Using Custom Power Devices , 2018, IEEE Access.

[30]  Rajiv Kapoor,et al.  Recognition of voltage sag causes using fractionally delayed biorthogonal wavelet , 2019 .

[31]  Hong-Liang Gao,et al.  Mitigation of low frequency oscillations in power systems based on Mamdani fuzzy inference , 2019, Trans. Inst. Meas. Control.