Design and Characterization of a Lightweight and Fully Portable Remote Actuation System for Use With a Hand Exoskeleton

Enabling individuals who are living with reduced mobility of the hand to utilize portable exoskeletons at home has the potential to deliver rehabilitation therapies with a greater intensity and relevance to activities of daily living. Various hand exoskeleton designs have been explored in the past, however, devices have remained nonportable and cumbersome for the intended users. Here we investigate a remote actuation system for wearable hand exoskeletons, which moves weight from the weakened limb to the shoulders, reducing the burden on the user and improving portability. A push-pull Bowden cable was used to transmit actuator forces from a backpack to the hand with strict attention paid to total system weight, size, and the needs of the target population. We present the design and integration of this system into a previously presented hand exoskeleton, as well as its characterization. Integration of remote actuation reduced the exoskeleton weight by 56% to 113g without adverse effects to functionality. Total actuation system weight was kept to 754g. The loss of positional accuracy inherent with Bowden cable transmissions was compensated for through closed loop positional control of the transmission output. The achieved weight reduction makes hand exoskeletons more suitable to the intended user, which will permit the study of their effectiveness in providing long duration, high intensity, and targeted rehabilitation as well as functional assistance.

[1]  Steven Laureys,et al.  Spasticity after stroke: Physiology, assessment and treatment , 2013, Brain injury.

[2]  Andreas Wege,et al.  Development and control of a hand exoskeleton for rehabilitation of hand injuries , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[3]  Michael Goldfarb,et al.  Design and performance characterization of a hand orthosis prototype to aid activities of daily living in a post-stroke population , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[4]  Daniel D. Frey,et al.  Efficiency of Prosthetic Cable and Housing , 1995 .

[5]  Grant D. Huang,et al.  Robot-assisted therapy for long-term upper-limb impairment after stroke. , 2010, The New England journal of medicine.

[6]  Mario Cortese,et al.  A Powered Finger–Thumb Wearable Hand Exoskeleton With Self-Aligning Joint Axes , 2015, IEEE/ASME Transactions on Mechatronics.

[7]  L. Ada,et al.  Stroke patients have selective muscle weakness in shortened range. , 2003, Brain : a journal of neurology.

[8]  Robert V Kenyon,et al.  A Pneumatic Glove and Immersive Virtual Reality Environment for Hand Rehabilitative Training After Stroke , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[9]  Talicia Tarver,et al.  HEART DISEASE AND STROKE STATISTICS–2014 UPDATE: A REPORT FROM THE AMERICAN HEART ASSOCIATION , 2014 .

[10]  S. K. Wee,et al.  Effects of a robot-assisted training of grasp and pronation/supination in chronic stroke: a pilot study , 2011, Journal of NeuroEngineering and Rehabilitation.

[11]  K. Y. Tong,et al.  An EMG-driven exoskeleton hand robotic training device on chronic stroke subjects: Task training system for stroke rehabilitation , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[12]  Frans C. T. van der Helm,et al.  Bowden Cable Actuator for Force-Feedback Exoskeletons , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[13]  Nikos G. Tsagarakis,et al.  A novel exoskeleton robotic system for hand rehabilitation - Conceptualization to prototyping , 2014 .

[14]  E. Burdet,et al.  Robot-assisted rehabilitation of hand function. , 2010, Current opinion in neurology.

[15]  Niels Smaby,et al.  Identification of key pinch forces required to complete functional tasks. , 2004, Journal of rehabilitation research and development.

[16]  D G Kamper,et al.  Kinetic and kinematic workspaces of the index finger following stroke. , 2005, Brain : a journal of neurology.

[17]  Brian Byunghyun Kang,et al.  Exo-Glove: A Wearable Robot for the Hand with a Soft Tendon Routing System , 2015, IEEE Robotics & Automation Magazine.

[18]  George M. Whitesides,et al.  Towards a soft pneumatic glove for hand rehabilitation , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[19]  Jumpei Arata,et al.  A new hand exoskeleton device for rehabilitation using a three-layered sliding spring mechanism , 2013, 2013 IEEE International Conference on Robotics and Automation.

[20]  Robert J. Wood,et al.  Soft robotic glove for combined assistance and at-home rehabilitation , 2015, Robotics Auton. Syst..

[21]  Conor J. Walsh,et al.  A pediatric robotic thumb exoskeleton for at-home rehabilitation: The Isolated Orthosis for Thumb Actuation (IOTA) , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[22]  Adel Al-Jumaily,et al.  Design and Development of a Hand Exoskeleton for Rehabilitation Following Stroke , 2012 .

[23]  J. Dewald,et al.  Task-dependent weakness at the elbow in patients with hemiparesis. , 1999, Archives of physical medicine and rehabilitation.

[24]  Shuguo Wang,et al.  Design and development of a hand exoskeleton for rehabilitation of hand injuries , 2014 .

[25]  T. Platz,et al.  Electromechanical and robot-assisted arm training for improving arm function and activities of daily living after stroke. , 2008, The Cochrane database of systematic reviews.

[26]  Edward A. Clancy,et al.  A soft robotic exomusculature glove with integrated sEMG sensing for hand rehabilitation , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[27]  Hong Kai Yap,et al.  A soft exoskeleton for hand assistive and rehabilitation application using pneumatic actuators with variable stiffness , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[28]  S. Gandevia,et al.  The distribution of muscular weakness in upper motor neuron lesions affecting the arm. , 1989, Brain : a journal of neurology.

[29]  Soo-Jin Lee,et al.  Current hand exoskeleton technologies for rehabilitation and assistive engineering , 2012 .

[30]  J. Dewald,et al.  Impact of gravity loading on post‐stroke reaching and its relationship to weakness , 2007, Muscle & nerve.

[31]  E. G. Cruz,et al.  Weakness is the primary contributor to finger impairment in chronic stroke. , 2006, Archives of physical medicine and rehabilitation.

[32]  Olivier Lambercy,et al.  Design of a thumb exoskeleton for hand rehabilitation , 2013 .

[33]  Mario Cortese,et al.  Kinematics and design of a portable and wearable exoskeleton for hand rehabilitation , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[34]  H. Kazerooni,et al.  Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX) , 2006, IEEE/ASME Transactions on Mechatronics.