A Method for Calibrating Diffusion Gradients in Diffusion Tensor Imaging

Objective: To calibrate and correct the gradient errors including gradient amplitude scaling errors, background/imaging gradients, and residual gradients in diffusion tensor imaging (DTI). Methods: A calibration protocol using an isotropic phantom was proposed. Gradient errors were estimated by using linear regression analyses on quadratic functions of diffusion gradients along 3 orthogonal directions. A 6-element total effective scaling vector is generated from the calibration protocol to retrospectively correct gradient errors in DTI experiments. Results: The accuracy of the calibration protocol was within 1% or less in estimating gradient scaling errors. On both the brain study and the computer simulations, the retrospective correction minimized undesirable estimate biases of DTI measurements due to gradient errors. Conclusion: The protocol and retrospective correction are shown to be effective. The method may be used for prospective correction if actual diffusion-gradient waveforms are available. The methodology is expandable to general diffusion imaging schemes.

[1]  M Hedehus,et al.  Diffusion-tensor MR imaging at 1.5 and 3.0 T: initial observations. , 2001, Radiology.

[2]  C Baldock,et al.  Test liquids for quantitative MRI measurements of self‐diffusion coefficient in vivo , 2000, Magnetic resonance in medicine.

[3]  T E Conturo,et al.  Diffusion MRI: Precision, accuracy and flow effects , 1995, NMR in biomedicine.

[4]  D. Tuch Q‐ball imaging , 2004, Magnetic resonance in medicine.

[5]  V. Wedeen,et al.  Mapping fiber orientation spectra in cerebral white matter with Fourier-transform diffusion MRI , 2000 .

[6]  P. Kuchel,et al.  Effect of nonrectangular field gradient pulses in the stejskal and tanner ( diffusion) pulse sequence , 1991 .

[7]  N J Pelc,et al.  Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imaging , 2003, Magnetic resonance in medicine.

[8]  E. Agranov,et al.  Diffusion anisotropy MRI for quantitative assessment of recovery in injured rat spinal cord , 2001, Magnetic resonance in medicine.

[9]  C. Tempelmann,et al.  Eddy current correction in diffusion‐weighted imaging using pairs of images acquired with opposite diffusion gradient polarity , 2004, Magnetic resonance in medicine.

[10]  K. Hasan,et al.  Diffusion tensor imaging of in vivo and excised rat spinal cord at 7 T with an icosahedral encoding scheme , 2005, Magnetic resonance in medicine.

[11]  F W Wehrli,et al.  Determination of Background Gradients with Diffusion MR Imaging , 1994, Journal of magnetic resonance imaging : JMRI.

[12]  Stephen M. Smith,et al.  A global optimisation method for robust affine registration of brain images , 2001, Medical Image Anal..

[13]  Michal Neeman,et al.  A simple method for obtaining cross‐term‐free images for diffusion anisotropy studies in NMR microimaging , 1991, Magnetic resonance in medicine.

[14]  D. Le Bihan Molecular diffusion, tissue microdynamics and microstructure. , 1995, NMR in biomedicine.

[15]  D L Parker,et al.  Comparison of gradient encoding schemes for diffusion‐tensor MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[16]  P. Basser,et al.  Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. , 1996, Journal of magnetic resonance. Series B.

[17]  James Mattiello,et al.  Analytical Calculation of the Matrix in Diffusion Imaging , 2006 .

[18]  A. Snyder,et al.  Quantitative diffusion-tensor anisotropy brain MR imaging: normative human data and anatomic analysis. , 1999, Radiology.

[19]  Robert Turner,et al.  Diffusion and perfusion magnetic resonance imaging , 1992 .

[20]  D’Orazio,et al.  Molecular diffusion and nuclear-magnetic-resonance relaxation of water in unsaturated porous silica glass. , 1990, Physical review. B, Condensed matter.

[21]  P. Basser,et al.  Toward a quantitative assessment of diffusion anisotropy , 1996, Magnetic resonance in medicine.

[22]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[23]  L. Frank Characterization of anisotropy in high angular resolution diffusion‐weighted MRI , 2002, Magnetic resonance in medicine.

[24]  P. V. van Zijl,et al.  Diffusion Weighting by the Trace of the Diffusion Tensor within a Single Scan , 1995, Magnetic resonance in medicine.