Smart, low-cost, pumpless loop for micro-channel electronic cooling using flat and enhanced surfaces

Two-phase cooling of a square simulated electronic device surface of 21.3 mm side was successfully carried out without the need for a pump. This smart, passive, low-cost cooling system incorporates a self-enhancing and self-sustaining mechanism, wherein the system inherently enhances its cooling capacity by increasing the velocity of the two-phase mixture along the boiling surface when an increase in heat flux is sensed. Other practical attributes of this pumpless loop are small liquid inventory requirements and absence of the incipient boiling temperature drop. It is shown small surface tension and contact angle render dielectric coolants such as FC-72 ideally suited for flow in narrow gaps. These unique properties are responsible for very small bubble size, precluding any appreciable blockage of the replenishment liquid flow even in narrow gaps. Critical heat flux (CHF) was found to generally increase with decreasing boiler gap. CHF for flat, micro-channel (with 0.2 mm rectangular fins) and mini-channel (with 1.98 mm rectangular fins) surfaces was 4.5, 5.9, and 5.7 times greater than for pool boiling from a flat surface for corresponding gaps. A pressure drop model was formulated to predict coolant mass flow rate, boiling surface inlet and exit velocities, and pressure drop components throughout the loop. The model predictions illustrate the pumpless loop's self-sustaining and self-enhancing attributes, and relate CHF trends to those of the two-phase mixture acceleration along the boiling surface.

[1]  B. S. Petukhov Heat Transfer and Friction in Turbulent Pipe Flow with Variable Physical Properties , 1970 .

[2]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[3]  M. Monde Characteristic of heat transfer enhancement due to bubbles passing through a narrow vertical channel , 1988 .

[4]  Issam Mudawar,et al.  Two-Phase Electronic Cooling Using Mini-Channel and Micro-Channel Heat Sinks: Part 1—Design Criteria and Heat Diffusion Constraints , 1994 .

[5]  Issam Mudawar Assessment of high-heat-flux thermal management schemes , 2001 .

[6]  J. Thome,et al.  Convective Boiling and Condensation , 1972 .

[7]  Kaneyasu Nishikawa,et al.  Saturated boiling heat transfer in narrow spaces , 1969 .

[8]  N. Zuber The Hydrodynamic Crisis in Pool Boiling of Saturated and Subcooled Liquids , 1963 .

[9]  I. Mudawar,et al.  Single- and Two-Phase Convective Heat Transfer From Smooth and Enhanced Microelectronic Heat Sources in a Rectangular Channel , 1989 .

[10]  I. Mudawar,et al.  Two-Phase Electronic Cooling Using Mini-Channel and Micro-Channel Heat Sinks: Part 2—Flow Rate and Pressure Drop Constraints , 1994 .

[11]  I. Mudawar,et al.  Microelectronic Cooling by Enhanced Pool Boiling of a Dielectric Fluorocarbon Liquid , 1989 .

[12]  I. Mudawar,et al.  Pumpless Loop for Narrow Channel and Micro-Channel Boiling compact cooling system is examined which capitalizes upon fluid density differences , 2003 .

[13]  I. Mudawar,et al.  Optimization of Enhanced Surfaces for High Flux Chip Cooling by Pool Boiling , 1993 .

[14]  R. Pease,et al.  High-performance heat sinking for VLSI , 1981, IEEE Electron Device Letters.

[15]  Issam Mudawar,et al.  High flux boiling in low flow rate, low pressure drop mini-channel and micro-channel heat sinks , 1994 .