Comparison of remote magnetic navigation ablation and manual ablation of idiopathic ventricular arrhythmia after failed manual ablation

PurposeCatheter ablation for idiopathic ventricular arrhythmia (VA) is effective and safe, but efficacy is frequently limited due to an epicardial origin and difficult anatomy. The remote magnetic navigation (RMN) catheter has a flexible catheter design allowing access to difficult anatomy. We describe the efficacy of the RMN for ablation of idiopathic VA after failed manual ablation.MethodsAmong 235 patients with idiopathic VA referred for catheter ablation, we identified 51 patients who were referred for repeat ablation after a failed manual ablation. We analyzed the clinical characteristics, including the successful ablation site and findings at electrophysiology study, in repeat procedures conducted using RMN as compared with manual ablation. Among these patients, 22 (43 %) underwent repeat ablation with the RMN and 29 (57 %) underwent repeat ablation with a manual ablation.ResultsOverall, successful ablation rate was significantly higher using RMN as compared with manual ablation (91 vs. 69 %, P = 0.02). Fluoroscopy time in the RMN was 17 ± 12 min as compared with 43 ± 18 min in the manual ablation (P = 0.009). Successful ablation rate in the posterior right ventricular outflow tract (RVOT) plus posterior-tricuspid annulus was higher with RMN as compared with manual ablation (92 vs. 50 %, P = 0.03). Neither groups exhibited any major complications.ConclusionsThe RMN is more effective in selected patients with recurrent idiopathic VA after failed manual ablation and is associated with less fluoroscopy time. The RMN catheters have a flexible design enabling them to access otherwise difficult anatomy including the posterior tricuspid annulus and posterior RVOT.

[1]  Vivek Y. Reddy,et al.  Remote Magnetic Navigation to Guide Endocardial and Epicardial Catheter Mapping of Scar-Related Ventricular Tachycardia , 2007, Circulation.

[2]  L. Jordaens,et al.  Catheter Ablation of Ventricular Tachycardias Using Remote Magnetic Navigation: A Consecutive Case–Control Study , 2012, Journal of cardiovascular electrophysiology.

[3]  L. Jordaens,et al.  Use of Advanced Mapping and Remote Magnetic Navigation to Ablate Left Ventricular Fascicular Tachycardia , 2006, Pacing and clinical electrophysiology : PACE.

[4]  L. Jordaens,et al.  Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardia. , 2006, Heart rhythm.

[5]  W. Saliba,et al.  Remote Magnetic Navigation to Map and Ablate Left Coronary Cusp Ventricular Tachycardia , 2006, Journal of cardiovascular electrophysiology.

[6]  Feifan Ouyang,et al.  Catheter ablation of right ventricular outflow tract tachycardia: a simplified remote-controlled approach. , 2011, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[7]  Shigeru Oshima,et al.  Idiopathic ventricular arrhythmias originating from the tricuspid annulus: Prevalence, electrocardiographic characteristics, and results of radiofrequency catheter ablation. , 2007, Heart rhythm.

[8]  G. Kay,et al.  Ventricular Tachycardia Originating From the Posterior Papillary Muscle in the Left Ventricle: A Distinct Clinical Syndrome , 2008, Circulation. Arrhythmia and electrophysiology.

[9]  L. Jordaens,et al.  Safety and efficacy of the remote magnetic navigation for ablation of ventricular tachycardias—a systematic review , 2011, Journal of Interventional Cardiac Electrophysiology.

[10]  A Natale,et al.  Ventricular tachycardias arising from the aortic sinus of valsalva: an under-recognized variant of left outflow tract ventricular tachycardia. , 2001, Journal of the American College of Cardiology.

[11]  S. Ernst,et al.  Repetitive monomorphic ventricular tachycardia originating from the aortic sinus cusp: electrocardiographic characterization for guiding catheter ablation. , 2002, Journal of the American College of Cardiology.

[12]  J. Kalman,et al.  Using the 12‐Lead ECG to Localize the Origin of Atrial and Ventricular Tachycardias: Part 2—Ventricular Tachycardia , 2009, Journal of cardiovascular electrophysiology.

[13]  W. Shimizu,et al.  Localization of optimal ablation site of idiopathic ventricular tachycardia from right and left ventricular outflow tract by body surface ECG. , 1998, Circulation.

[14]  S. Ernst,et al.  Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory. , 2006, European heart journal.

[15]  L. Jordaens,et al.  Outcomes of repeat catheter ablation using magnetic navigation or conventional ablation. , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[16]  J. Burkhardt,et al.  Endo-epicardial ablation of ventricular arrhythmias in the left ventricle with the Remote Magnetic Navigation System and the 3.5-mm open irrigated magnetic catheter: results from a large single-center case-control series. , 2010, Heart rhythm.

[17]  K. Cao,et al.  Magnetic versus manual catheter navigation for mapping and ablation of right ventricular outflow tract ventricular arrhythmias: a randomized controlled study. , 2013, Heart rhythm.

[18]  B. Lindsay,et al.  Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation , 2002, Circulation.

[19]  M. Gollob,et al.  Remote Magnetic Navigation‐Assisted Catheter Ablation Enhances Catheter Stability and Ablation Success with Lower Catheter Temperatures , 2008, Pacing and clinical electrophysiology : PACE.

[20]  WataruShimizu,et al.  Localization of Optimal Ablation Site of Idiopathic Ventricular Tachycardia from Right and Left Ventricular Outflow Tract by Body Surface ECG , 1998 .

[21]  Fred H M Wittkampf,et al.  RF Catheter Ablation: Lessons on Lesions , 2006, Pacing and clinical electrophysiology : PACE.

[22]  F. Marchlinski,et al.  Repetitive monomorphic tachycardia from the left ventricular outflow tract: electrocardiographic patterns consistent with a left ventricular site of origin. , 1997, Journal of the American College of Cardiology.

[23]  A. Nogami,et al.  Idiopathic ventricular arrhythmia arising from the mitral annulus: a distinct subgroup of idiopathic ventricular arrhythmias. , 2005, Journal of the American College of Cardiology.

[24]  T. Bunch,et al.  Right Meets Left: A Common Mechanism Underlying Right and Left Ventricular Outflow Tract Tachycardias , 2006, Journal of cardiovascular electrophysiology.