Building Pathology, Investigation of Sick Buildings —Toxic Moulds

This paper considers the requirements for investigation of sick buildings including some guidelines for assessment of exposure risks with a particular focus on dampness, proliferation of moulds, and dispersion of fungal spores in indoor environments. Building pathology, indoors air quality management and management of bio-deterioration, and health problems in buildings are complex issues requiring multi-disciplinary investigations and environmental monitoring. Lack of maintenance, chronic neglect, and building defects leading to water ingress, condensation, and dampness in the building fabric will often produce proliferation of pathogenic toxic moulds, and other microbial and biological effects that could cause allergic response in sensitive people and generally lead to ‘‘sick buildings.’’ A general guide has been provided by this paper for environmental assessment of toxic moulds in indoor environments, including a suggested guideline for assessing the threshold levels for fungal spores in indoor air.

[1]  Jagjit Singh,et al.  Investigating dry rot in buildings , 1995 .

[2]  A Seaton,et al.  Asthma admissions and thunderstorms: a study of pollen, fungal spores, rainfall, and ozone. , 2001, QJM : monthly journal of the Association of Physicians.

[3]  Who Regional Office for Europe,et al.  WHO Guidelines for Indoor Air Quality: Dampness and Mould , 2009 .

[4]  Joseph W. Lstiburek,et al.  Moisture Control Handbook: Principles and Practices for Residential and Small Commercial Buildings , 1993 .

[5]  Jagjit Singh Dry Rot and Other Wood-Destroying Fungi: Their Occurrence, Biology, Pathology and Control , 1999, Indoor and Built Environment.

[6]  Lucas B. Hyman,et al.  Primary chilled water loop retrofit , 2000 .

[7]  M. Chapman Challenges associated with indoor moulds: Health effects, immune response and exposure assessment. , 2006, Medical mycology.

[8]  Jeong Tai Kim,et al.  Building Pathology, Investigation of Sick Buildings — VOC Emissions , 2010 .

[9]  B. Flannigan Indoor Microbiological Pollutants — Sources, Species, Characterisation and Evaluation , 1992 .

[10]  B. Flannigan,et al.  Mould in buildings: the air spora of domestic dwellings , 1988 .

[11]  M. Ghannoum,et al.  Indoor Mold, Toxigenic Fungi, and Stachybotrys chartarum: Infectious Disease Perspective , 2003, Clinical Microbiology Reviews.

[12]  Ingrid Šenitková,et al.  Indoor air quality of the office buildings , 2010 .

[13]  S. Brown Indoor Air Quality in Australian Buildings , 2004 .

[14]  Karin Foarde,et al.  Efficacy of Antimicrobial filter treatments , 1999 .

[15]  Ashley Woodcock,et al.  Moulds and asthma: time for indoor climate change? , 2007, Thorax.

[16]  G. Moretti,et al.  [Mycetes and bacteria]. , 1967, Minerva dermatologica.

[17]  R. Burnett,et al.  Influence of ambient fungal spores on emergency visits for asthma to a regional children's hospital. , 2000, American Journal of Respiratory and Critical Care Medicine.

[18]  Andrew M. Pope,et al.  Indoor Allergens—Assessing and Controlling Adverse Health Effects , 1993 .

[19]  J.David Miller,et al.  Fungi as contaminants in indoor air , 1992 .

[20]  W. Sorenson,et al.  Fungal spores: hazardous to health? , 1999, Environmental health perspectives.

[21]  Jagjit Singh Biological contaminants in the built environment and their health implications , 1993 .

[22]  Jagjit Singh,et al.  Review : Dry Rot and Other Wood-Destroying Fungi: Their Occurrence, Biology, Pathology and Control , 1999 .