MRI in patients with pacemakers: overview and procedural management.

BACKGROUND Magnetic resonance imaging (MRI) is generally contraindicated for patients with a pacemaker (PM) or implantable cardiac defibrillator (ICD), because of the risk of life-threatening interference with the device. Nevertheless, the question whether to perform MRI despite the presence of these devices can still arise when MRI is vitally indicated. In some hospitals, special precautionary measures are taken so that MRI can be performed in such cases. METHODS This review is based on the authors' experience in 42 patients who underwent MRI at our university hospital, on the pertinent literature, and on the recommendations of medical societies. RESULTS Because of its excellent image quality, MRI is often an indispensable diagnostic tool. Structured multidisciplinary management enables it to be performed safely even in patients with a PM or ICD. Pre- and post-MRI checks of the device are recommended, as well as extensive monitoring and the availability of the necessary personnel to deal with an emergency. In general, the pacing and defibrillator functions should be deactivated; for pacemaker-dependent patients, the asynchronous pacing mode should be activated. No serious incidents have occurred when these precautions have been observed, either among our own patients or in the literature. Newer PM systems have been approved for MRI scanning under certain conditions. CONCLUSION In patients with a PM or ICD, the benefit of MRI may far outweigh its risks if the indication has been established for the particular patient as an interdisciplinary decision and if the appropriate precautions are observed during scanning. Now that newer PM systems have been approved for MRI scanning, the problem seems close to being solved.

[1]  M. Mollerus,et al.  Cardiac Biomarkers in Patients with Permanent Pacemakers and Implantable Cardioverter‐Defibrillators Undergoing an MRI Scan , 2008, Pacing and clinical electrophysiology : PACE.

[2]  Robert Fair,et al.  Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla. , 2004, Journal of the American College of Cardiology.

[3]  H. Ghanbari,et al.  A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI) , 2010, Journal of Interventional Cardiac Electrophysiology.

[4]  P. Tchou,et al.  Strategies for the Safe Magnetic Resonance Imaging of Pacemaker‐Dependent Patients , 2005, Pacing and clinical electrophysiology : PACE.

[5]  J. Gimbel Magnetic Resonance Imaging of Implantable Cardiac Rhythm Devices at 3.0 Tesla , 2008, Pacing and clinical electrophysiology : PACE.

[6]  J. Gimbel Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker. , 2009, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[7]  Daniel B Ennis,et al.  Pacemaker lead tip heating in abandoned and pacemaker‐attached leads at 1.5 tesla MRI , 2011, Journal of magnetic resonance imaging : JMRI.

[8]  Werner Irnich,et al.  Do we need pacemakers resistant to magnetic resonance imaging? , 2005, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[9]  Peter Hunold,et al.  Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. , 2011, Heart rhythm.

[10]  P Boesiger,et al.  Force and Torque Effects of a 1.5‐Tesla MRI Scanner on Cardiac Pacemakers and ICDs , 2001, Pacing and clinical electrophysiology : PACE.

[11]  C. Woertgen,et al.  Pyogenic spinal infections and outcome according to the 36-item short form health survey. , 2006, Journal of neurosurgery. Spine.

[12]  O. Faris,et al.  Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients. , 2006, Circulation.

[13]  Peter Boesiger,et al.  In vivo heating of pacemaker leads during magnetic resonance imaging. , 2005, European heart journal.

[14]  C. Meyer,et al.  MRT-Untersuchungen des Hirns bei Patienten mit implantierten Herzschrittmachern. Experimentelle und klinische Untersuchungen an einem 1,5 Tesla-System , 2005 .

[15]  K Bachmann,et al.  Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. , 1997, American heart journal.

[16]  R. Fimmers,et al.  Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/defibrillators at 1.5 T. , 2011, American heart journal.

[17]  Harold Litt,et al.  Strategy for Safe Performance of Extrathoracic Magnetic Resonance Imaging at 1.5 Tesla in the Presence of Cardiac Pacemakers in Non–Pacemaker-Dependent Patients: A Prospective Study With 115 Examinations , 2006, Circulation.

[18]  P. Boesiger,et al.  Pacemaker Reed Switch Behavior in 0.5, 1.5, and 3.0 Tesla Magnetic Resonance Imaging Units: Are Reed Switches Always Closed in Strong Magnetic Fields? , 2002, Pacing and clinical electrophysiology : PACE.

[19]  Ron Kalin,et al.  Current Clinical Issues for MRI Scanning of Pacemaker and Defibrillator Patients , 2005, Pacing and clinical electrophysiology : PACE.

[20]  P. Pattany,et al.  Safety of serial MRI in patients with implantable cardioverter defibrillators , 2011, Heart.

[21]  J M Fontaine,et al.  Rapid Ventricular Pacing in a Pacemaker Patient Undergoing Magnetic Resonance Imaging , 1998, Pacing and clinical electrophysiology : PACE.

[22]  J. Gummert,et al.  Current pacemaker and defibrillator therapy. , 2011, Deutsches Arzteblatt international.

[23]  A. Jensen,et al.  Increasing frequency of vertebral osteomyelitis following Staphylococcus aureus bacteraemia in Denmark 1980-1990. , 1997, The Journal of infection.

[24]  R. Fimmers,et al.  Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: pilot prospective study with 51 examinations. , 2008, Radiology.

[25]  Henry R. Halperin,et al.  Modern Pacemaker and Implantable Cardioverter/Defibrillator Systems Can Be Magnetic Resonance Imaging Safe: In Vitro and In Vivo Assessment of Safety and Function at 1.5 T , 2004, Circulation.

[26]  H. Halperin,et al.  A Prospective Evaluation of a Protocol for Magnetic Resonance Imaging of Patients With Implanted Cardiac Devices , 2011, Annals of Internal Medicine.

[27]  H. Halperin,et al.  Clinical Utility and Safety of a Protocol for Noncardiac and Cardiac Magnetic Resonance Imaging of Patients With Permanent Pacemakers and Implantable-Cardioverter Defibrillators at 1.5 Tesla , 2006, Circulation.

[28]  H. Schild,et al.  Low-field magnetic resonance imaging: increased safety for pacemaker patients? , 2010, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[29]  S. Priori,et al.  Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[30]  M. Mollerus,et al.  Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions. , 2010, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[31]  R. Fimmers,et al.  Evaluation of Cumulative Effects of MR Imaging on Pacemaker Systems at 1.5 Tesla , 2009, Pacing and clinical electrophysiology : PACE.

[32]  J Gieseke,et al.  MR imaging and cardiac pacemakers: in-vitro evaluation and in-vivo studies in 51 patients at 0.5 T. , 2000, Radiology.

[33]  D. Skowasch,et al.  [Magnetic resonance imaging of the brain in patients with cardiac pacemakers. Experimental and clinical investigations at 1.5 Tesla]. , 2005, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.